AAC CENTRO DE ACUSTICA APLICADA
Official name: AAC CENTRO DE ACUSTICA APLICADA, S.L.
8 capabilities
Verified Apr 2026
One of 1,173 in Spain
Details
Parque Tecnologico De Alava. C/ Leonardo Da Vinci, 14
Vitoria-Gasteiz 01510 , Spain
Vitoria-Gasteiz 01510 , Spain
Accreditation
Active
ENAC
LE229
Conducts in-situ acoustic testing including environmental noise sampling and measurement of machinery sound power levels using engineering and control methods, as well as workplace sound pressure level determination and acoustic intensity measurements.
Accreditation Details
Accreditation Body
ENAC
Number
LE229
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official ENAC records.
Download Scope PDFSend an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.
Test Capabilities (8)
| Standard Reference | Description | Category |
|---|---|---|
| ISO 1996-2 | Environmental noise โ determination of sound levels (ISO 1996-2) | Noise / Acoustics |
| UNE-EN ISO 11200 | UNE-EN ISO 11200 | Noise / Acoustics |
| UNE-EN ISO 11201 | UNE-EN ISO 11201 | Noise / Acoustics |
| UNE-EN ISO 11202 | UNE-EN ISO 11202 | Noise / Acoustics |
| UNE-EN ISO 11204 | UNE-EN ISO 11204 | Noise / Acoustics |
| UNE-EN ISO 3744 | UNE-EN ISO 3744 | Noise / Acoustics |
| UNE-EN ISO 3746 | UNE-EN ISO 3746 | Noise / Acoustics |
| UNE-EN ISO 9614-2 | UNE-EN ISO 9614-2 | Noise / Acoustics |