AMBITEC LABORATORIOS, S.L. (Unipersonal)

50 capabilities Verified Jul 2026 One of 1,189 in Spain
Send Enquiry

Send one structured enquiry and we chase the reply for you. No cold email, no chasing.

Details

Calle 1, nº 13, Parcela 7. Polígono Industrial Picassent
Picassent 46220 , Spain

Accreditation

Active ENAC LE327
www.ambiteclaboratorios.com Prefer to enquire through us? Send an enquiry

Performs water quality testing on drinking water, continental water, wastewater, and marine samples with emphasis on physical-chemical analysis, including groundwater sampling and assessment.

Accreditation Details

Accreditation Body

ENAC

Number

LE327

Status

Active

Accreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official ENAC records.

Download Scope PDF

Test Capabilities (50)

Standard Reference Description Category
UNE-EN ISO 11348-3 UNE-EN ISO 11348-3 Biocompatibility (ISO 10993)
EN ISO 5815-1 ISO 5815-1 Chemical
EPA 1664 EPA 1664 Chromatography (GC, HPLC)
ISO 5667-9 ISO 5667-9 Corrosion / Salt Spray
EPA 245.1 EPA 245.1 Drinking Water Analysis
EPA 9214 EPA 9214 Drinking Water Analysis
ISO 5667 - 5 ISO 5667-5 Drinking Water Analysis
SM 2130 B SM 2130 B Drinking Water Analysis
SM 2340 A SM 2340 A Drinking Water Analysis
SM 2510 B SM 2510 B Drinking Water Analysis
SM 2540 F SM 2540 F Drinking Water Analysis
SM 2540 G SM 2540 G Drinking Water Analysis
SM 4500 - Cl- B SM 4500-Cl- B Drinking Water Analysis
SM 4500 - H+ B SM 4500-H+ B Drinking Water Analysis
SM 4500 - N A SM 4500-N A Drinking Water Analysis
SM 4500 NH -C 3 SM 4500-NH C 3 Drinking Water Analysis
SM 4500 Norg B SM 4500-Norg B Drinking Water Analysis
SM 4500 O - G SM 4500-O G Drinking Water Analysis
SM 4500 P E SM 4500-P E Drinking Water Analysis
SM 4500 S2-D SM 4500-S2-D Drinking Water Analysis
UNE 77031 UNE 77031 Drinking Water Analysis
UNE EN 26777 UNE-EN 26777 Drinking Water Analysis
UNE EN ISO 19458 UNE-EN ISO 19458 Drinking Water Analysis
UNE EN ISO 8467 UNE-EN ISO 8467 Drinking Water Analysis
UNE-EN 1484 UNE-EN 1484 Drinking Water Analysis
UNE-EN ISO 7393-2 UNE-EN ISO 7393-2 Drinking Water Analysis
UNE-EN 13342 UNE-EN 13342 EMC / EMI Testing
SM 3500 Cr B SM 3500 Cr B Electrical
ISO 5667-11 ISO 5667-11 Environmental / Surface Water
ISO 5667-4 ISO 5667-4 Environmental / Surface Water
SM 2320 B SM 2320 B Environmental / Surface Water
SM 2330 B SM 2330 B Environmental / Surface Water
SM 4500 NH B- C 3 SM 4500 NH B- C 3 Environmental / Surface Water
SM 4500 NH3 D SM 4500-NH3 D Environmental / Surface Water
SM 4500 NH3 F SM 4500-NH3 F Environmental / Surface Water
SM 5540 C SM 5540 C Environmental / Surface Water
UNE EN ISO 5667-6 UNE-EN ISO 5667-6 Environmental / Surface Water
UNE-EN ISO 5667 UNE-EN ISO 5667 Environmental / Surface Water
SM 3114 B SM 3114 B Lubricants / Oils
UNE EN ISO 11885 UNE-EN ISO 11885 Spectroscopy (XRF, ICP, AAS)
EPA 7470 EPA 7470 Temperature / Pressure
EPA 7471 EPA 7471 Temperature / Pressure
SM 5220 D SM 5220 D Temperature / Pressure
UNE-EN 14899 UNE-EN 14899 Temperature / Pressure
ISO 5667 - 10 ISO 5667-10 Wastewater / Effluent Testing
SM 4500-SO42- E SM 4500-SO42- E Wastewater / Effluent Testing
SM 5530 D SM 5530 D Wastewater / Effluent Testing
UNE EN 15216 UNE-EN 15216 Wastewater / Effluent Testing
UNE EN 872 UNE-EN 872 Wastewater / Effluent Testing
SM 2550 SM 2550 Water & Wastewater

Send an Enquiry

Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.

Please select a test method from the list
Report incorrect or outdated information
0 labs selected
Compare