Bilfinger Maintenance Netherlands
Official name: Bilfinger Maintenance Netherlands B.V.
11 capabilities
Verified Apr 2026
One of 582 in Netherlands
Details
Postbus 33
Hengelo Ov 7550 AA , Netherlands
Hengelo Ov 7550 AA , Netherlands
Accreditation
Active
RvA
I276
Performs radiographic testing of metals and welded constructions using X-ray techniques, with acceptance criteria aligned to ASME pressure vessel and piping codes.
Accreditation Details
Accreditation Body
RvA
Number
I276
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official RvA records.
Download Scope PDFSend an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.
Test Capabilities (11)
| Standard Reference | Description | Category |
|---|---|---|
| EN 1090-2 | DIN EN 1090-2 | Construction Materials |
| EN 13445-5 | EN 13445-5 | Fire / Flammability |
| ISO 23278 | ISO 23278 | Fire / Flammability |
| NEN 3650-2 | NEN 3650-2 | Fire / Flammability |
| EN 12952-6 | DIN EN 12952-6 | Non-Destructive Testing (NDT) |
| EN 13480-5 | DIN EN 13480-5 | Non-Destructive Testing (NDT) |
| ISO 3452-1 | รNORM EN ISO 3452-1 | Penetrant Testing (PT) |
| ISO 17636-1 | รNORM EN ISO 17636-1 | Radiographic Testing (RT) |
| ISO 10675-1 | BS EN ISO 10675-1 | Ultrasonic Testing (UT) |
| ISO 17638 | BS BS EN ISO 17638:2016 | Ultrasonic Testing (UT) |
| ISO 23277 | ISO 23277 | Ultrasonic Testing (UT) |