CIRCUTOR, S.A. (Unipersonal)

30 capabilities Verified May 2026 One of 1,179 in Spain

Details

C/ Vial Sant Jordi, s/n
Viladecavalls , Spain

Accreditation

Active ENAC LE2532

Performs electromagnetic compatibility testing, human exposure to electromagnetic field evaluation, electrical safety testing, and environmental testing of electrical equipment and electronic devices.

Accreditation Details

Accreditation Body

ENAC

Number

LE2532

Status

Active

Accreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official ENAC records.

Download Scope PDF
30 capabilities

Send an Enquiry

Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.

Please select a test method from the list

Test Capabilities (30)

Standard Reference Description Category
IEC 60068-2-1 IEC 60068-2-1 Climate / Temperature Cycling
IEC 60068-2-2 IEC 60068-2-2 Climate / Temperature Cycling
IEC 60068-2-78 IEC 60068-2-78 Climate / Temperature Cycling
UNE-EN 60068-2-1 UNE-EN 60068-2-1 Climate / Temperature Cycling
UNE-EN 60068-2-2 UNE-EN 60068-2-2 Climate / Temperature Cycling
CISPR 16-2-1 IEC/CISPR 16-2-1 EMC / EMI Testing
UNE EN 61000-4-5 UNE EN 61000-4-5 EMC / EMI Testing
UNE-EN 55016-2-1 UNE-EN 55016-2-1 EMC / EMI Testing
UNE-EN 61000-4-11 UNE-EN 61000-4-11 EMC / EMI Testing
UNE-EN 61000-4-2 UNE-EN 61000-4-2 EMC / EMI Testing
UNE-EN 61000-4-4 UNE-EN 61000-4-4 EMC / EMI Testing
UNE-EN 61000-4-6 UNE-EN 61000-4-6 EMC / EMI Testing
UNE-EN 61000-4-8 UNE-EN 61000-4-8 EMC / EMI Testing
UNE-EN 61000-6-1 UNE-EN 61000-6-1 EMC / EMI Testing
UNE-EN 61000-6-2 UNE-EN 61000-6-2 EMC / EMI Testing
UNE-EN 61000-6-3 UNE-EN 61000-6-3 EMC / EMI Testing
UNE-EN 61000-6-4 UNE-EN 61000-6-4: 2007 EMC / EMI Testing
0° ≤ ɸ ≤ 360° 45 Hz ≤ f ≤ 65 Hz 23 V ≤ U ≤ 400 V 10 mA ≤ I < 0,1 A 0,1 A ≤ I ≤ 21 A 0° ≤ ɸ ≤ 360° 45 Hz ≤ f ≤ 65 Hz 23 V ≤ U ≤ 400 V 10 mA ≤ I < 0,1 A 0,1 A ≤ I ≤ 21 A Other
0° ≤ ɸ ≤ 360° 45 Hz ≤ f ≤ 65 Hz Tensión V1: 23 V ≤ V1 ≤ 400 V Tensión V2: 200 mV ≤ V2 < 250 mV 250 mV ≤ V2 < 600 mV 600 mV ≤ V2 < 1,5 V 1,5 V ≤ V2 < 4 V 4 V ≤ V2 < 10 V 0° ≤ ɸ ≤ 360° 45 Hz ≤ f ≤ 65 Hz Tensión V1: 23 V ≤ V1 ≤ 400 V Tensión V2: 200 mV ≤ V2 < 250 mV 250 mV ≤ V2 < 600 mV 600 mV ≤ V2 < 1,5 V 1,5 V ≤ V2 < 4 V 4 V ≤ V2 < 10 V Other
10 Hz ≤ f ≤ 1 MHz 10 Hz ≤ f ≤ 1 MHz Other
10 Hz ≤ f ≤ 120 Hz 120 Hz ≤ f ≤ 1,2 kHz 1,2 kHz ≤ f ≤ 12 kHz 12 kHz ≤ f ≤ 120 kHz 120 kHz ≤ f ≤ 2 MHz 10 Hz ≤ f ≤ 120 Hz 120 Hz ≤ f ≤ 1,2 kHz 1,2 kHz ≤ f ≤ 12 kHz 12 kHz ≤ f ≤ 120 kHz 120 kHz ≤ f ≤ 2 MHz Other
10 mV ≤ U < 200 mV 200 mV ≤ U < 2,0 V 2,0 V ≤ U < 20 V 20 V ≤ U < 200 V 200 V ≤ U ≤ 1050 V 10 mV ≤ U < 200 mV 200 mV ≤ U < 2,0 V 2,0 V ≤ U < 20 V 20 V ≤ U < 200 V 200 V ≤ U ≤ 1050 V Other
10 mV ≤ U < 330 mV 330 mV ≤ U < 3,3 V 3,3 V ≤ U < 33 V 33 V ≤ U < 330 V 330 V ≤ U ≤ 1020 V 10 mV ≤ U < 330 mV 330 mV ≤ U < 3,3 V 3,3 V ≤ U < 33 V 33 V ≤ U < 330 V 330 V ≤ U ≤ 1020 V Other
100 µA ≤ I < 200 µA 200 µA ≤ I < 2,0 mA 2,0 mA ≤ I < 20 mA 20 mA ≤ I < 200 mA 200 mA ≤ I < 2,0 A 2,0 A ≤ I ≤ 20 A 100 µA ≤ I < 200 µA 200 µA ≤ I < 2,0 mA 2,0 mA ≤ I < 20 mA 20 mA ≤ I < 200 mA 200 mA ≤ I < 2,0 A 2,0 A ≤ I ≤ 20 A Other
50 Hz y 60 Hz 500 V < U ≤ 6 000 V 50 Hz y 60 Hz 500 V < U ≤ 6 000 V Other
500 V < U ≤ 6000 V 6 k V < U ≤ 20 k V 500 V < U ≤ 6000 V 6 k V < U ≤ 20 k V Other
Puntos fijos R= 1MΩ; 5MΩ; 10MΩ; 50MΩ; 100MΩ; 500MΩ; 1GΩ; 5GΩ; 10GΩ; 15GΩ y 20GΩ Puntos fijos R= 1MΩ; 5MΩ; 10MΩ; 50MΩ; 100MΩ; 500MΩ; 1GΩ; 5GΩ; 10GΩ; 15GΩ y 20GΩ Other
UNE-EN 61010-1 UNE-EN 61010-1 Product Safety (IEC 60335, IEC 62368)
UNE-EN 61010-2-030 UNE-EN 61010-2-030 Product Safety (IEC 60335, IEC 62368)
UNE-EN 60068-2-78 UNE-EN 60068-2-78 Vibration / Shock
Report incorrect or outdated information
0 labs selected
Compare