ENUSA INDUSTRIAS AVANZADAS, S.A., S.M.E.
51 capabilities
Verified Apr 2026
One of 1,173 in Spain
Details
Ctra. Salamanca-Ledesma, Km.26 Aptdo. 328
Juzbado 37115 , Spain
Juzbado 37115 , Spain
Accreditation
Active
ENAC
LE735
Specialises in environmental radiological testing of drinking water, surface water, soils, sediments and atmospheric capture filters, along with wastewater analysis and heavy metals determination.
Accreditation Details
Accreditation Body
ENAC
Number
LE735
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official ENAC records.
Download Scope PDFSend an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.
Test Capabilities (51)
| Standard Reference | Description | Category |
|---|---|---|
| ISO 13161 | ISO 13161 | Chromatography (GC, HPLC) |
| ASTM C1844 | ASTM C1844 | Concrete / Cement |
| ISO 23655-1 | ISO 23655-1 | Contaminants / Heavy Metals |
| ISO 7890-3 | ISO 7890-3 | Contaminants / Heavy Metals |
| EPA 335.2 | EPA 335.2 | Drinking Water Analysis |
| EPA 356.2 | EPA 356.2 | Drinking Water Analysis |
| EPA 365.2 | EPA 365.2 | Drinking Water Analysis |
| EPA 375.4 | EPA 375.4 | Drinking Water Analysis |
| EPA 908.1 | EPA 908.1 | Drinking Water Analysis |
| ISO 14911 | UNE-EN ISO 14911 | Drinking Water Analysis |
| SM 2130 B | SM 2130 B | Drinking Water Analysis |
| SM 2340 | SM 2340 | Drinking Water Analysis |
| SM 2340 B | SM 2340 B | Drinking Water Analysis |
| SM 2340 C | SM 2340 C | Drinking Water Analysis |
| SM 3114 C | SM 3114 C | Drinking Water Analysis |
| SM 3500 K B | SM 3500 K B | Drinking Water Analysis |
| SM 4500 - H+ B | SM 4500-H+ B | Drinking Water Analysis |
| SM 4500 - NH F 3 | SM 4500-NH F 3 | Drinking Water Analysis |
| SM 4500 NH - D 3 | SM 4500-NH D 3 | Drinking Water Analysis |
| SM 4500 SO 2- E 4 | SM 4500-SO 2-E 4 | Drinking Water Analysis |
| SM 4500- SO 2- 4 | SM 4500- SO 2- 4 | Drinking Water Analysis |
| SM 4500-Si E | SM 4500-Si E | Drinking Water Analysis |
| UNE 73340-1 | UNE 73340-1 | Drinking Water Analysis |
| UNE EN ISO 10304-1 | UNE-EN ISO 10304-1 | Drinking Water Analysis |
| UNE EN ISO 8467 | UNE-EN ISO 8467 | Drinking Water Analysis |
| UNE EN ISO 9698 | UNE-EN ISO 9698 | Drinking Water Analysis |
| UNE-EN ISO 13162 | UNE-EN ISO 13162 | Drinking Water Analysis |
| UNE-EN ISO 17294-2 | UNE-EN ISO 17294-2 | Drinking Water Analysis |
| UNE-EN ISO 22515 | UNE-EN ISO 22515 | Drinking Water Analysis |
| UNE-EN ISO 7393-2 | UNE-EN ISO 7393-2 | Drinking Water Analysis |
| EPA 909.0 | EPA 909.0 | Electrical |
| SM 2120 C | SM 2120 C | Electrical |
| UNE 73340-2 | UNE 73340-2 | Electrical |
| UNE-EN IEC 62387 | UNE-EN IEC 62387 | Electrical Safety |
| EPA 410.4 | EPA 410.4 | Environmental / Surface Water |
| ISO 10704 | ISO 10704 | Environmental / Surface Water |
| ISO 11905-1 | UNE-EN ISO 11905-1 | Environmental / Surface Water |
| ISO 13160 | UNE-EN ISO 13160 | Environmental / Surface Water |
| ISO 13167 | ISO 13167 | Environmental / Surface Water |
| SM 5540 | SM 5540 | Environmental / Surface Water |
| SM 5540 C | SM 5540 C | Environmental / Surface Water |
| UNE-EN ISO 13164-4 | UNE-EN ISO 13164-4 | Environmental / Surface Water |
| ASTM D1426 | ASTM D1426 | Fuel Testing |
| ASTM D5174 | ASTM D5174 | Fuel Testing |
| UNE EN 27888 | UNE EN 27888 | Legionella / Microbiological |
| ISO 27048 | ISO 27048 | Lubricants / Oils |
| EN 13166 | ISO 13166 | Spectroscopy (XRF, ICP, AAS) |
| UNE EN ISO 9963-1 | UNE-EN ISO 9963-1 | Temperature / Pressure |
| ISO 20042 | UNE-EN ISO 20042 | Wastewater / Effluent Testing |
| SM 7500-Ra | SM 7500-Ra | Wastewater / Effluent Testing |
| UNE EN 872 | UNE-EN 872 | Wastewater / Effluent Testing |