EQUIPOS NUCLEARES, S.A., S.M.E.
75 capabilities
Verified Apr 2026
One of 1,173 in Spain
Details
AVDA.DE JUAN CARLOS I, 8
Maliaño 39600 , Spain
Maliaño 39600 , Spain
Accreditation
Active
ENAC
LE1853
Performs mechanical and hardness testing of metallic materials, including tensile testing up to 1000 kN, impact testing (Pellini drop-weight), and hardness determination across Brinell, Rockwell, and Vickers scales to ISO and ASTM standards.
Accreditation Details
Accreditation Body
ENAC
Number
LE1853
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official ENAC records.
Download Scope PDFSend an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.
Test Capabilities (75)
| Standard Reference | Description | Category |
|---|---|---|
| EN 50504 (2008) | EN 50504 | CE Marking Compliance |
| CEM DI-003 | CEM DI-003 | Dimensional / Geometric |
| CEM DI-004 | CEM DI-004 | Dimensional / Geometric |
| CEM DI-005 | CEM DI-005 | Dimensional / Geometric |
| CEM DI-008 | CEM DI-008 | Dimensional / Geometric |
| CEM DI-009 | CEM DI-009 | Dimensional / Geometric |
| CEM DI-010 | CEM DI-010 | Dimensional / Geometric |
| CEM DI-011 | CEM DI-011 | Dimensional / Geometric |
| CEM DI-016 | CEM DI-016 | Dimensional / Geometric |
| CEM DI-020 | CEM DI-020 | Dimensional / Geometric |
| EURAMET CG-10 | EURAMET CG-10 | Dimensional / Geometric |
| ISO 3650 | nach DIN EN ISO 3650:1999 | Dimensional / Geometric |
| ASTM E1019 | ASTM E 1019 | Elemental Analysis |
| EN 875 (1996) | DIN EN ISO 6887-5 | Food Safety Testing |
| ASTM E10 | ASTM E 10 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E10-18 | ASTM E 10-18 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E18 | ASTM E 18 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E18-20 | ASTM E 18-20 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E18-22 | ASTM E 18-22 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E18-24 | ASTM E18-24 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E384 | ASTM E 384 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E384-17 | ASTM E 384-17 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E92 | ASTM E 92 | Hardness (Vickers, Rockwell, Brinell) |
| UNE 7475-1 (1992) | UNE 7475-1 | Hardness (Vickers, Rockwell, Brinell) |
| UNE EN ISO 6506-1 | UNE-EN ISO 6506-1 | Hardness (Vickers, Rockwell, Brinell) |
| UNE EN ISO 6507-1 | UNE-EN ISO 6507-1 | Hardness (Vickers, Rockwell, Brinell) |
| UNE EN ISO 6508-1 | UNE-EN ISO 6508-1 | Hardness (Vickers, Rockwell, Brinell) |
| UNE EN ISO 9015-1 | UNE-EN ISO 9015-1 | Hardness (Vickers, Rockwell, Brinell) |
| UNE-EN 1043-1 (1996) | UNE-EN 1043-1 | Hardness (Vickers, Rockwell, Brinell) |
| UNE-EN ISO 7438 | UNE-EN ISO 7438 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E208 | ASTM E 208 | Impact / Charpy / Izod |
| ASTM E208-06 | ASTM E208-06 | Impact / Charpy / Izod |
| ASTM E208-91 | ASTM E208-91 | Impact / Charpy / Izod |
| ASTM E23 | ASTM E 23 | Impact / Charpy / Izod |
| ASTM E23-18 | ASTM E 23-18 | Impact / Charpy / Izod |
| ASTM E23-22 | ASTM E23-22 | Impact / Charpy / Izod |
| ASTM E23-23a | ASTM E 23-23A | Impact / Charpy / Izod |
| ASTM E23-24 | ASTM E23-24 | Impact / Charpy / Izod |
| EN 10045-1 (1990) | DIN EN 10045-1 | Impact / Charpy / Izod |
| UNE EN ISO 148-1 | UNE-EN ISO 148-1 | Impact / Charpy / Izod |
| UNE EN ISO 9016 | UNE-EN ISO 9016 | Impact / Charpy / Izod |
| CEM ME-010 | CEM ME-010 | Mechanical |
| EN 910 (1996) | Laktoseintoleranz, 13910 | Molecular Diagnostics / PCR |
| ASTM E340-15 | ASTM E340-15 | Non-Destructive Testing (NDT) |
| CEM DI-021 | CEM DI-021 | Other |
| CEM DI-022 | CEM DI-022 | Other |
| CEM ME-003 | CEM ME-003 | Other |
| UNE-EN ISO 4136-2013 | UNE-EN ISO 4136-2013 | Penetrant Testing (PT) |
| UNE-EN IEC 60974-14 | UNE-EN IEC 60974-14 | Product Safety (IEC 60335, IEC 62368) |
| UNE EN ISO 17639 | UNE-EN ISO 17639 | Radiographic Testing (RT) |
| ASTM E1086 | ASTM E 1086 | Spectroscopy (XRF, ICP, AAS) |
| ASTM E340 | ASTM E 340 | Spectroscopy (XRF, ICP, AAS) |
| ASTM E415 | ASTM E 415 | Spectroscopy (XRF, ICP, AAS) |
| ASTM E384-11e1 | ASTM E384-11e1 | Temperature / Pressure |
| CEM TH-001 | CEM TH-001 | Temperature / Pressure |
| CEM TH-003 | CEM TH-003 | Temperature / Pressure |
| CEM TH-005 | CEM TH-005 | Temperature / Pressure |
| ASTM E190 | ASTM E 190 | Tensile / Compression / Flexural |
| ASTM E21 | ASTM E 21 | Tensile / Compression / Flexural |
| ASTM E21-17e1 | ASTM E 21-17E1 | Tensile / Compression / Flexural |
| ASTM E290 | ASTM E290 | Tensile / Compression / Flexural |
| ASTM E8 | ASTM E 8 | Tensile / Compression / Flexural |
| EN 10002-1 (2001) | DIN EN 10002-1 | Tensile / Compression / Flexural |
| EN 10002-5 (1991) | DIN EN 10002-5 | Tensile / Compression / Flexural |
| UNE 7364 | UNE 7364 | Tensile / Compression / Flexural |
| UNE EN ISO 4136 | UNE-EN ISO 4136 | Tensile / Compression / Flexural |
| UNE EN ISO 5173 | UNE-EN ISO 5173 | Tensile / Compression / Flexural |
| UNE EN ISO 5178 | UNE-EN ISO 5178 | Tensile / Compression / Flexural |
| UNE EN ISO 6892-1 | UNE-EN ISO 6892-1 | Tensile / Compression / Flexural |
| UNE-EN 1321 (1997) | UNE-EN 1321 | Tensile / Compression / Flexural |
| UNE-EN 876 (1996) | UNE-EN 876 | Tensile / Compression / Flexural |
| UNE-EN 895 (1996) | UNE-EN 895 | Tensile / Compression / Flexural |
| UNE-EN ISO 6892-2 | UNE-EN ISO 6892-2 | Tensile / Compression / Flexural |
| ASTM E23-23 | ASTM E23-23 | Ultrasonic Testing (UT) |
| UNE EN ISO 8492 | UNE-EN ISO 8492 | Ultrasonic Testing (UT) |