HELLA GmbH & Co. KGaA
127 capabilities
Accredited since June 2025
Verified Sep 2026
One of 3,103 in Germany
Send one structured enquiry and we chase the reply for you. No cold email, no chasing.
Details
Beckumer Straße 130
Lippstadt 59555 , Germany
Lippstadt 59555 , Germany
Accreditation
Active
DAkkS
D-K-18930-02-01
Offers broad calibration capabilities in electrical measuring quantities covering DC and low-frequency measurements including voltage, current, resistance, and frequency/speed measurement with measurement ranges from millivolts to kilovolts.
Accreditation Details
Accreditation Body
DAkkS
Number
D-K-18930-02-01
Status
ActiveSince
11 June 2025
Accreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official DAkkS records.
Download Scope PDF
Test Capabilities (127)
| Standard Reference | Description | Category |
|---|---|---|
| DIN EN 60068-2-30 | DIN EN 60068-2-30 | Climate / Temperature Cycling |
| DIN EN 60068-2-38 (2010-06) | IEC/EN 60068-2-38:2009 Part 2-38: | Climate / Temperature Cycling |
| DIN EN 60068-2-52 (1996-10) | UNE-EN 60068-2-52 | Climate / Temperature Cycling |
| DIN EN 60068-2-67 (2020) | DIN EN 60068-2-67 | Climate / Temperature Cycling |
| DIN EN-60068-2-1 (2008-01) | DIN EN-60068-2-1 | Climate / Temperature Cycling |
| DIN EN-60068-2-2 (2008-05) | DIN EN-60068-2-2 | Climate / Temperature Cycling |
| IEC 60068-2-1 | IEC 60068-2-1 | Climate / Temperature Cycling |
| IEC 60068-2-11 | DIN EN IEC 60068-2-11 | Climate / Temperature Cycling |
| IEC 60068-2-2 | IEC 60068-2-2 | Climate / Temperature Cycling |
| IEC 60068-2-27 | IEC 60068-2-27 | Climate / Temperature Cycling |
| IEC 60068-2-64 | IEC 60068-2-64 | Climate / Temperature Cycling |
| IEC 60068-2-78 | IEC 60068-2-78 | Climate / Temperature Cycling |
| ISO 16750-3 | ISO 16750-3 | Climate / Temperature Cycling |
| ISO 20653 | ISO 20653 | Component / Parts Testing |
| DIN EN ISO 9227 (2017-07) | BS ISO 9227:2022 | Corrosion / Salt Spray |
| IEC 60068-2-80 | IEC 60068-2-80 | Corrosion / Salt Spray |
| Volumenmessgeräte | Volumenmessgeräte | Dimensional / Geometric |
| − Anwendung Koordinatenmessgeräte | − Anwendung Koordinatenmessgeräte | Dimensional / Geometric |
| IEC 60721-3-2 (2018) | IEC 60721-3-2 | EMC / EMI Testing |
| ISO 10605 (2008) | ISO 10605 | EMC / EMI Testing |
| ISO 11452-11 | ISO 11452-11 | EMC / EMI Testing |
| ISO 11452-2: 2019 | ISO 11452-2: 2019 | EMC / EMI Testing |
| ISO 11452-4: 2020 | ISO 11452-4: 2020 | EMC / EMI Testing |
| ISO 11452-5: 2002 | ISO 11452-5: 2002 | EMC / EMI Testing |
| ISO 11452-8: 2015 | ISO 11452-8: 2015 | EMC / EMI Testing |
| ISO 11452-9: 2012 | ISO 11452-9: 2012 | EMC / EMI Testing |
| ISO 7637-2 (2011) | ISO 7637-2 | EMC / EMI Testing |
| ISO 7637-3: 2016 | ISO 7637-3: 2016 | EMC / EMI Testing |
| - Gleichspannung | - Gleichspannung | Electrical |
| - Gleichstromwiderstand | - Gleichstromwiderstand | Electrical |
| - Wechselspannung | - Wechselspannung | Electrical |
| - Wechselstromstärke | - Wechselstromstärke | Electrical |
| / Messgeräte | / Messgeräte | Electrical |
| 0,2 mΩ | 0,2 mΩ | Electrical |
| 0,20mA | 0,20mA | Electrical |
| 0,220 V | 0,220 V | Electrical |
| 0,33 kΩ | 0,33 kΩ | Electrical |
| 1,1 MΩ | 1,1 MΩ | Electrical |
| 1,1 kΩ | 1,1 kΩ | Electrical |
| 11 MΩ | 11 MΩ | Electrical |
| 11 kΩ | 11 kΩ | Electrical |
| 110 MΩ | 110 MΩ | Electrical |
| 110 kΩ | 110 kΩ | Electrical |
| 110 Ω | 110 Ω | Electrical |
| 200 V | 200 V | Electrical |
| 200 mA | 200 mA | Electrical |
| 3,3 MΩ | 3,3 MΩ | Electrical |
| 3,3 kΩ | 3,3 kΩ | Electrical |
| 33 MΩ | 33 MΩ | Electrical |
| 330 MΩ | 330 MΩ | Electrical |
| > 0,022 V | > 0,022 V | Electrical |
| > 0,2 mA | > 0,2 mA | Electrical |
| > 0,22mA | > 0,22mA | Electrical |
| > 1,2 A | > 1,2 A | Electrical |
| > 1,4 A | > 1,4 A | Electrical |
| > 1,6 A | > 1,6 A | Electrical |
| > 1,8 A | > 1,8 A | Electrical |
| > 100 mA | > 100 mA | Electrical |
| > 110 Ω bis 330 Ω | > 110 Ω bis 330 Ω | Electrical |
| > 120 MΩ | > 120 MΩ | Electrical |
| > 120 kΩ | > 120 kΩ | Electrical |
| > 120 mA | > 120 mA | Electrical |
| > 140 mA | > 140 mA | Electrical |
| > 160 mA | > 160 mA | Electrical |
| > 180 mA | > 180 mA | Electrical |
| > 2,0 mA | > 2,0 mA | Electrical |
| > 2,2 mA | > 2,2 mA | Electrical |
| > 2,2 mV bis | > 2,2 mV bis | Electrical |
| > 20 mA | > 20 mA | Electrical |
| > 200 MΩ | > 200 MΩ | Electrical |
| > 200 mA | > 200 mA | Electrical |
| > 200 Ω | > 200 Ω | Electrical |
| > 22 V bis 220 V | > 22 V bis 220 V | Electrical |
| > 22 mA | > 22 mA | Electrical |
| > 22 mA bis 220 mA | > 22 mA bis 220 mA | Electrical |
| > 220 V | > 220 V | Electrical |
| > 220 mA | > 220 mA | Electrical |
| > 220 mV | > 220 mV | Electrical |
| > 33 kΩ | > 33 kΩ | Electrical |
| > 330 kΩ | > 330 kΩ | Electrical |
| > 330 Ω | > 330 Ω | Electrical |
| >200 kΩ | >200 kΩ | Electrical |
| Elektrische Messgrößen 0,1 mV | Elektrische Messgrößen 0,1 mV | Electrical |
| Frequenz | Frequenz | Electrical |
| Generatoren 0,1 Hz | Generatoren 0,1 Hz | Electrical |
| Gleichspannung 0,1 mV | Gleichspannung 0,1 mV | Electrical |
| Gleichstromstärke 0,1 µA | Gleichstromstärke 0,1 µA | Electrical |
| Gleichstromstärke 0,9 µA | Gleichstromstärke 0,9 µA | Electrical |
| Gleichstromwiderstand 50 µΩ bis | Gleichstromwiderstand 50 µΩ bis | Electrical |
| Messgeräte > 2,2 mA | Messgeräte > 2,2 mA | Electrical |
| Messgeräte > 220 µA | Messgeräte > 220 µA | Electrical |
| Quellen | Quellen | Electrical |
| Wechselspannung 0,22 mV | Wechselspannung 0,22 mV | Electrical |
| Wechselspannung > 70 mV bis 220 mV | Wechselspannung > 70 mV bis 220 mV | Electrical |
| Wechselstromstärke 0,2 mA | Wechselstromstärke 0,2 mA | Electrical |
| Wechselstromstärke > 220 µA | Wechselstromstärke > 220 µA | Electrical |
| Widerstände | Widerstände | Electrical |
| DIN EN ISO 1183-1 (2019-09) | DIN EN ISO 1183-1 | Elemental Analysis |
| ISO 1183-1 (2019-03) | ISO 1183-1 | Elemental Analysis |
| *) > 30 % | *) > 30 % | Temperature / Pressure |
| > 50 % | Umluft > 50 % | Temperature / Pressure |
| Feuchtemessgrößen | Feuchtemessgrößen | Temperature / Pressure |
| Klimaschränke mit | Klimaschränke mit | Temperature / Pressure |
| Klimaschränken mit | Klimaschränken mit | Temperature / Pressure |
| Messorte in | Messorte in | Temperature / Pressure |
| Temperaturmessgrößen | Temperaturmessgrößen | Temperature / Pressure |
| Thermohygrogra- > 50 % | Thermohygrogra- > 50 % | Temperature / Pressure |
| Umluft | Umluft | Temperature / Pressure |
| Umluft > -40 °C | Umluft > -40 °C | Temperature / Pressure |
| Umluft > 30 % | Umluft > 30 % | Temperature / Pressure |
| relativen > 80 % | relativen > 80 % | Temperature / Pressure |
| ISO 306 (2022-11) | ISO 306 | Tensile / Compression / Flexural |
| DIN EN 10306 (2002-04) | DIN EN 10306 | Ultrasonic Testing (UT) |
| DIN EN 60068-2-14 | DIN EN 60068-2-14 | Vibration / Shock |
| DIN EN 60068-2-64 | DIN EN 60068-2-64 | Vibration / Shock |
| DIN EN 60068-2-67 | DIN EN 60068-2-67 | Vibration / Shock |
| DIN EN 60068-2-78 | DIN EN 60068-2-78 | Vibration / Shock |
| DIN EN 60068-2-80 | DIN EN 60068-2-80 | Vibration / Shock |
| DIN EN-60068-2-27 (2010-02) | DIN EN-60068-2-27 | Vibration / Shock |
| DIN EN-60068-2-6 (2008-10) | DIN EN-60068-2-6 | Vibration / Shock |
| IEC 60068-2-14 | IEC 60068-2-14 | Vibration / Shock |
| IEC 60068-2-30 | IEC 60068-2-30 | Vibration / Shock |
| IEC 60068-2-38 | DIN EN IEC 60068-2-38 | Vibration / Shock |
| IEC 60068-2-52 | DIN EN IEC 60068-2-52 | Vibration / Shock |
| IEC 60068-2-6 | IEC 60068-2-6 | Vibration / Shock |
| IEC 60068-2-67 | IEC 60068-2-67 | Vibration / Shock |
| ISO 16750-4 | ISO 16750-4 | Vibration / Shock |
Send an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.