HORIBA MIRA
Official name: HORIBA MIRA Limited
75 capabilities
Verified Jul 2026
One of 2,381 in United Kingdom
Send one structured enquiry and we chase the reply for you. No cold email, no chasing.
Details
Watling Street, Nuneaton
Nuneaton CV10 0TU , United Kingdom
Nuneaton CV10 0TU , United Kingdom
Accreditation
Active
UKAS
1105
horiba-mira.com
Prefer to enquire through us? Send an enquiry
Conducts electromagnetic compatibility and emissions testing of motor vehicles, components, and automotive-related products including conducted, magnetic, and radiated emissions to CISPR and ECE standards.
Accreditation Details
Accreditation Body
UKAS
Number
1105
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official UKAS records.
Download Scope PDF
Test Capabilities (75)
| Standard Reference | Description | Category |
|---|---|---|
| ISO 16750-2:2012 | ISO 16750-2: 2012 | Climate / Temperature Cycling |
| (CISPR 25:2002) Section 6 | (CISPR 25:2002) Section 6 | EMC / EMI Testing |
| BS EN 14511:2022 Parts 1-4 | ISO 11451-1 | EMC / EMI Testing |
| BS EN 50082-1:1998 | DIN EN 50082-1 | EMC / EMI Testing |
| BS EN 55025:2017 Excluding clauses 5, 6.6 & 6.7 | DIN EN 55025: 2018 | EMC / EMI Testing |
| BS EN 61000-3-11: 2001 | IEC 61000-3-11: 2017 | EMC / EMI Testing |
| BS EN 61326:1996 | DIN EN 61326 | EMC / EMI Testing |
| BS EN IEC 55025:2022 | EN IEC 55025 | EMC / EMI Testing |
| BS EN IEC 55036:2020 | EN IEC 55036 | EMC / EMI Testing |
| BS ISO 10605:2008 including | BS ISO 10605:2008 including | EMC / EMI Testing |
| CISPR 12:2001 | IEC/CISPR 12 | EMC / EMI Testing |
| CISPR 14-2:1997 | IEC/CISPR 14-2 | EMC / EMI Testing |
| CISPR 25:1995 | IEC/CISPR 25 | EMC / EMI Testing |
| EN 301 489-1:V1.4.1:2002 | DIN EN 301489-1 | EMC / EMI Testing |
| EN 301 489-3:V1.6.1-2013 | DIN EN 301489-3 | EMC / EMI Testing |
| EN 50498:2010 | DIN EN 50498: 2011 | EMC / EMI Testing |
| EN 55011:2007, Amd A1 & A2 | DIN EN 55011: 2018 | EMC / EMI Testing |
| EN 55014-1:2017 | DIN EN 55014-1: 2018 | EMC / EMI Testing |
| EN 55014-2:1997, Amd A1 | DIN EN 55014-2: 2016 | EMC / EMI Testing |
| EN 55016-2-1:2009+A1:2011 | DIN EN 55016-2-1 | EMC / EMI Testing |
| EN 55016-2-3:2010+A1:2014 | DIN EN 55016-2-3: 2020 | EMC / EMI Testing |
| EN 55022:2010 | DIN EN 55022: 2011 | EMC / EMI Testing |
| EN 55032:2015 | DIN EN 55032 | EMC / EMI Testing |
| EN 61000-3-2:2014 | IEC 61000-3-2: 2014 | EMC / EMI Testing |
| EN 61000-3-3:2013 | IEC 61000-3-3 | EMC / EMI Testing |
| EN 61000-4-2:2009 | IEC 61000-4-2: 2008 | EMC / EMI Testing |
| EN 61000-4-3:2006, Amd 1:2008 | IEC 61000-4-3: 2006 | EMC / EMI Testing |
| EN 61000-4-4:1995 | IEC 61000-4-4: 2012 | EMC / EMI Testing |
| EN 61000-4-5:2014 | IEC 61000-4-5: 2005 | EMC / EMI Testing |
| EN 61000-4-6:2014 | IEC 61000-4-6: 2013 | EMC / EMI Testing |
| EN 61000-4-8:2010 | IEC 61000-4-8: 2009 | EMC / EMI Testing |
| EN 61000-6-2:2005 | IEC 61000-6-2: 2005 | EMC / EMI Testing |
| EN 61000-6-3:2007 | IEC 61000-6-3: 2006 | EMC / EMI Testing |
| EN 61000-6-4:2007 | IEC 61000-6-4: 2006 | EMC / EMI Testing |
| EN IEC 61000-4-11: 2020 | IEC 61000-4-11: 2004 | EMC / EMI Testing |
| EN IEC 61000-6-1:2019 | IEC 61000-6-1 | EMC / EMI Testing |
| EN IEC 61000-6-8:2020 | IEC 61000-6-8 | EMC / EMI Testing |
| FCC CFR 47:Part 15B:2008 | FCC CFR 47:Part 15B:2008 | EMC / EMI Testing |
| IEC 1000-4-8:1993 | IEC 1000-4-8:1993 | EMC / EMI Testing |
| IEC 61000-3-12: 2011 + A1:2021 | IEC 61000-3-12: 2011 | EMC / EMI Testing |
| IEC 61326:1997 | EN IEC 61326 | EMC / EMI Testing |
| ISO 10605:2008 Am1:2014 | ISO 10605 | EMC / EMI Testing |
| ISO 11451-2:1995 | ISO 11451-2: 2015 | EMC / EMI Testing |
| ISO 11451-3:2007 | ISO 11451-3 | EMC / EMI Testing |
| ISO 11451-4:1995 | ISO 11451-4: 2013 | EMC / EMI Testing |
| ISO 11452-1:2005 | ISO 11452-1 | EMC / EMI Testing |
| ISO 11452-2:1995 200 MHz to 18 GHz | ISO 11452-2: 2019 | EMC / EMI Testing |
| ISO 11452-3:1995 | ISO 11452-3 | EMC / EMI Testing |
| ISO 11452-4:1995 1 MHz to 400 MHz | ISO 11452-4: 2020 | EMC / EMI Testing |
| ISO 11452-5:2002 | ISO 11452-5: 2002 | EMC / EMI Testing |
| ISO 11452-8:2008 | ISO 11452-8: 2015 | EMC / EMI Testing |
| ISO 11452-9:2012 | ISO 11452-9: 2012 | EMC / EMI Testing |
| ISO 13309:2010 | ISO 13309:2010 | EMC / EMI Testing |
| ISO 7637-1:1990 | ISO 7637-1 | EMC / EMI Testing |
| ISO 7637-2:2004 | ISO 7637-2 | EMC / EMI Testing |
| ISO 7637-3:1995 | ISO 7637-3: 2016 | EMC / EMI Testing |
| ISO DIS 11451-3:2003 | ISO DIS 11451-3:2003 | EMC / EMI Testing |
| ISO TR 10605/E:1994 (Component | ISO TR 10605/E:1994 (Component | EMC / EMI Testing |
| PD IEC TS 62764-1: 2019 | PD IEC TS 62764-1: 2019 | EMC / EMI Testing |
| EN 1317-2:2010 | EN 1317-2 | Impact / Charpy / Izod |
| EN 1317-3:2010 | EN 1317-3 | Impact / Charpy / Izod |
| EN 13171:2012 + A1:2015 | EN 1317-1 | Impact / Charpy / Izod |
| ANSI C63.4:2014 | ANSI C63.4:2014 | Radio Frequency |
| BS EN IEC 62764-1: 2022 | IEC 62764-1 | Radio Frequency |
| EN IEC 62311:2020 | EN IEC 62311 | Radio Frequency |
| ASTM F2656\F2656M-20 | ASTM F2656\F2656M-20 | Tensile / Compression / Flexural |
| ASTM F2656\F2656M-23 | ASTM F2656\F2656M-23 | Tensile / Compression / Flexural |
| EN ISO 14982:2009 | ISO 14982 | Tensile / Compression / Flexural |
| ISO 13766:2006 | ISO 13766 | Tensile / Compression / Flexural |
| BS EN ISO 13766-2: 2018 | ISO 13766-2: 2018 | Transport / Rail Testing |
| EN 12895:2000 | DIN EN 12895: 2020 | Transport / Rail Testing |
| EN 13309:2000 | DIN EN 13309: 2010 | Transport / Rail Testing |
| ISO 13766-1:2018 | ISO 13766-1: 2018 | Transport / Rail Testing |
| BS EN 12767:2019 | DIN EN 12767 | Vibration / Shock |
| ISO 22343-1:2023 | ISO 22343-1 | Vibration / Shock |
Send an Enquiry