IDE ELECTRIC
Official name: IDE ELECTRIC, S.L.
12 capabilities
Verified Apr 2026
One of 1,173 in Spain
Details
CALLE LEONARDO DA VINCI nยบ2
Zuera 50800 , Spain
Zuera 50800 , Spain
Accreditation
Active
ENAC
LE2674
Performs electrical, functional, and safety testing of low-voltage switchgear enclosures and protection degree assessment against mechanical impacts, excluding certain thermal, ultraviolet, and corrosion-related tests.
Accreditation Details
Accreditation Body
ENAC
Number
LE2674
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official ENAC records.
Download Scope PDFSend an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.
Test Capabilities (12)
| Standard Reference | Description | Category |
|---|---|---|
| EN ISO 9227 | Salt spray / neutral salt fog test (ISO 9227) | Corrosion / Salt Spray |
| UNE EN ISO 9227 | UNE-EN ISO 9227 | Corrosion / Salt Spray |
| IEC 62262 | IEC 62262 | Electrical Safety |
| IEC 60529 | IEC 60529: 1989 | Product Safety (IEC 60335, IEC 62368) |
| IEC 62208 | IEC 62208: 2011-08 | Product Safety (IEC 60335, IEC 62368) |
| UNE-EN 60529 | UNE-EN 60529 | Product Safety (IEC 60335, IEC 62368) |
| UNE-EN 62208 | UNE-EN 62208 | Product Safety (IEC 60335, IEC 62368) |
| UNE-EN 62262 | UNE-EN 62262 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60695-2-11 | IEC 60695-2-11 | Reaction to Fire |
| UNE-EN 60695-10-2 | UNE-EN 60695-10-2 | Reaction to Fire |
| UNE-EN IEC 60695-2-11 | UNE-EN IEC 60695-2-11 | Reaction to Fire |
| IEC 60695-10-2 | IEC 60695- 10-2: 2014 | Resistance to Fire |