KEMA
Official name: KEMA B.V.
126 capabilities
Verified Jul 2026
One of 584 in Netherlands
Send one structured enquiry and we chase the reply for you. No cold email, no chasing.
Details
Klingelbeekseweg 195
Arnhem 6812 DE , Netherlands
Arnhem 6812 DE , Netherlands
Accreditation
Active
RvA
I049
www.cesi.it
Prefer to enquire through us? Send an enquiry
Provides extensive inspection services for electrical products and power systems, including EMC/EMI testing, electrical safety assessment, and high-voltage testing for rotating electrical machines, transformers, and related equipment.
Accreditation Details
Accreditation Body
RvA
Number
I049
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official RvA records.
Download Scope PDFAdditional scope documents
Test Capabilities (126)
| Standard Reference | Description | Category |
|---|---|---|
| EN 50336 | DIN EN 17503-36 | Chromatography (GC, HPLC) |
| IEC 60567 | DIN EN IEC 60567 | Chromatography (GC, HPLC) |
| IEC 60068-2-1 | IEC 60068-2-1 | Climate / Temperature Cycling |
| IEC 60068-2-2 | IEC 60068-2-2 | Climate / Temperature Cycling |
| IEC 60068-2-27 | IEC 60068-2-27 | Climate / Temperature Cycling |
| IEC 60068-2-75 | IEC 60068-2-75 | Climate / Temperature Cycling |
| IEC 60068-2-78 | IEC 60068-2-78 | Climate / Temperature Cycling |
| IEC 60085 | IEC 60085 | Climate / Temperature Cycling |
| IEC 60297-3-101 | IEC 60297-3-101 | Dimensional / Geometric |
| EN 1106 | IEC 62271-106: 2021 | EMC / EMI Testing |
| EN 50470-1 | DIN EN 50470-1 | EMC / EMI Testing |
| EN 55022 | DIN EN 55022: 2011 | EMC / EMI Testing |
| EN 55032 | DIN EN 55032 | EMC / EMI Testing |
| EN 61000-4-6 | IEC 61000-4-6: 2013 | EMC / EMI Testing |
| EN 61000-4-8 | IEC 61000-4-8: 2009 | EMC / EMI Testing |
| IEC 60255-1 | DIN EN IEC 60255-1 | EMC / EMI Testing |
| IEC 60255-26 | IEC 60255-26 | EMC / EMI Testing |
| IEC 61000-4-10 | IEC 61000-4-10: 2016 | EMC / EMI Testing |
| IEC 61000-4-11 | IEC 61000-4-11: 2004 | EMC / EMI Testing |
| IEC 61000-4-12 | IEC 61000-4-12 | EMC / EMI Testing |
| IEC 61000-4-16 | IEC 61000-4-16: 2015 | EMC / EMI Testing |
| IEC 61000-4-17 | IEC 61000-4-17: 2009 | EMC / EMI Testing |
| IEC 61000-4-18 | IEC 61000-4-18: 2019 | EMC / EMI Testing |
| IEC 61000-4-19 | IEC 61000-4-19 | EMC / EMI Testing |
| IEC 61000-4-2 | IEC 61000-4-2: 2008 | EMC / EMI Testing |
| IEC 61000-4-20 | IEC 61000-4-20 | EMC / EMI Testing |
| IEC 61000-4-29 | IEC 61000-4-29: 2000 | EMC / EMI Testing |
| IEC 61000-4-4 | IEC 61000-4-4: 2012 | EMC / EMI Testing |
| IEC 61000-4-5 | IEC 61000-4-5: 2005 | EMC / EMI Testing |
| IEC 61000-4-9 | IEC 61000-4-9: 2016 | EMC / EMI Testing |
| IEC 61850-3 | IEC 61850-3: 2014 | EMC / EMI Testing |
| IEC 62053- 11 | IEC 62053-11 | EMC / EMI Testing |
| IEC 62054-21 | IEC 62054-21 | EMC / EMI Testing |
| IEC 62055-31 | IEC 62055-31:2005 (Withdrawn) | EMC / EMI Testing |
| IEC 62271-100 | IEC 62271-100: 2021 | EMC / EMI Testing |
| IEC 62271-101 | IEC 62271-101 | EMC / EMI Testing |
| IEC 62271-102 | IEC 62271-102: 2018 | EMC / EMI Testing |
| IEC 62271-103 | IEC 62271-103: 2021 | EMC / EMI Testing |
| IEC 62271-105 | IEC 62271-105: 2021 | EMC / EMI Testing |
| IEC 62271-200 | IEC 62271-200: 2021 | EMC / EMI Testing |
| IEC 62271-201 | IEC 62271-201 | EMC / EMI Testing |
| EN 50470 | EN 50470 | Electrical |
| EN 50470-2 | DIN EN 50470-2 | Electrical |
| HCS LF 0 0 | HCS LF 0 0 | Electrical |
| HCS LF 3 0 | HCS LF 3 0 | Electrical |
| HCS LF 3 2 | HCS LF 3 2 | Electrical |
| HCS LF 3 3 | HCS LF 3 3 | Electrical |
| HCS LF 4 3 | HCS LF 4 3 | Electrical |
| HCS LF 6 0 | HCS LF 6 0 | Electrical |
| HCS LF 6 2 | HCS LF 6 2 | Electrical |
| IEC 60092-350 | IEC 60092-350 | Electrical |
| IEC 60502 | IEC 60502:2014 | Electrical |
| IEC 60831-1 | IEC 60831-1 | Electrical |
| IEC 60871-4 | IEC 60871-4 | Electrical |
| IEC 61466-1 | IEC 61466-1 | Electrical |
| IEC 61466-2 | IEC 61466-2 | Electrical |
| IEC 61952 | IEC 61952 | Electrical |
| IEC 62052-11 | IEC 62052-11 | Electrical |
| IEC 62052-31 | IEC 62052-31 | Electrical |
| IEC 62217 | IEC 62217 | Electrical |
| IEC 62271-104 | IEC 62271-104 | Electrical |
| IEC 62271-203 | IEC 62271-203 | Electrical |
| IEC 60044-7 | IEC 60044-7 | Electrical Safety |
| IEC 60076 | IEC 60076 | Electrical Safety |
| IEC 60214-1 | IEC 60214-1 | Electrical Safety |
| IEC 60255-12 | IEC 60255-12 | Electrical Safety |
| IEC 60255-121 | IEC 60255-121 | Electrical Safety |
| IEC 60255-13 | IEC 60255-13 | Electrical Safety |
| IEC 60255-149 | IEC 60255-149 | Electrical Safety |
| IEC 62895 | DIN IEC 62895 | Electrical Safety |
| IEC 62271-205 | IEC 62271-205 | Electromagnetic |
| IEC 60702-1 | IEC 60702-1:2002+AMD1:2015 | Elemental Analysis |
| HCS LF 4 0 | HCS LF 4 0 | Fire / Flammability |
| HCS LF 4 2 | HCS LF 4 2 | Fire / Flammability |
| IEC 60034 | IEC 60034 | Fire / Flammability |
| IEC 60034-27-1 | IEC 60034-27-1 | Fire / Flammability |
| IEC 60034-4-1 | IEC 60034-4-1 | Fire / Flammability |
| EN 50329 | DIN EN 50329 | High Voltage Testing |
| HCS LF 1 3 | HCS LF 1 3 | High Voltage Testing |
| IEC 60060-1 | DIN IEC 60060-1 | High Voltage Testing |
| IEC 60137 | IEC 60137 | High Voltage Testing |
| IEC 60507 | IEC 60507 | High Voltage Testing |
| IEC 60840 | IEC 60840 | High Voltage Testing |
| IEC 61442 | IEC 61442 | High Voltage Testing |
| IEC 62067 | DIN IEC 62067 | High Voltage Testing |
| IEC 62231 | IEC 62231: 2006-02 | High Voltage Testing |
| IEC 62271-209 | IEC 62271-209: 2019-02 | High Voltage Testing |
| IEC 60255-151 | IEC 60255-151 | Installation / Wiring Testing |
| EN 50181 | EN 50181 | Product Safety (IEC 60335, IEC 62368) |
| EN 50243 | EN 50243 | Product Safety (IEC 60335, IEC 62368) |
| EN 50588-1 | EN 50588-1 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60034-2- 1 | IEC 60034-2-1 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60055 | IEC 60055 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60076-6 | IEC 60076-6 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60255-127 | IEC 60255-127 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60255-27 | IEC 60255-27: 2013 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60317-0-2 | IEC 60317-0-2 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60317-18 | IEC 60317-18 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60317-27-3 | IEC 60317-27-3 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60358 | IEC 60358 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60383 | IEC 60383 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60437 | IEC 60437 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60529 | IEC 60529: 1989 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60599 | IEC 60599 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60660 | IEC 60660 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60815 | IEC 60815 | Product Safety (IEC 60335, IEC 62368) |
| IEC 60871-1 | IEC 60871-1 | Product Safety (IEC 60335, IEC 62368) |
| IEC 61109 | IEC 61109: 2008-05 | Product Safety (IEC 60335, IEC 62368) |
| IEC 61869 | IEC 61869 | Product Safety (IEC 60335, IEC 62368) |
| IEC 62059-32-1 | IEC 62059-32-1:2011 | Product Safety (IEC 60335, IEC 62368) |
| IEC 63026 | IEC 63026: 2019-12 | Product Safety (IEC 60335, IEC 62368) |
| NEN 3172 | NEN 3172 | Product Safety (IEC 60335, IEC 62368) |
| NEN 3616 | NEN 3616 | Product Safety (IEC 60335, IEC 62368) |
| NEN 3619 | NEN 3619 | Product Safety (IEC 60335, IEC 62368) |
| EN 60349-1 | IEC 60349-1 | Rail Dynamic Behaviour / Running Tests |
| IEC 60349-4 | IEC 60349-4 | Rail Dynamic Behaviour / Running Tests |
| IEC 60141-1 | IEC 60141-1 | Tensile / Compression / Flexural |
| IEC 60168 | IEC 60168 | Tensile / Compression / Flexural |
| IEC 61089 | IEC 61089 | Tensile / Compression / Flexural |
| IEC 60034-18-1 | IEC 60034-18-1 | Ultrasonic Testing (UT) |
| IEC 60068 2-6 | IEC 60068-2-6 | Vibration / Shock |
| IEC 60068-2-14 | IEC 60068-2-14 | Vibration / Shock |
| IEC 60068-2-30 | IEC 60068-2-30 | Vibration / Shock |
| IEC 60255-21-1 | IEC 60255-21-1 | Vibration / Shock |
| IEC 60255-21-2 | IEC 60255-21-2 | Vibration / Shock |
| IEC 60255-21-3 | IEC 60255-21-3 | Vibration / Shock |
Send an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.