Official name: KWR Water B.V.
14 capabilities
Verified Apr 2026
One of 582 in Netherlands
Details
Postbus 1072
Nieuwegein 3430 BB , Netherlands
Nieuwegein 3430 BB , Netherlands
Accreditation
Active
RvA
L479
Tests drinking water and aquatic environments for organic and inorganic contaminants, including total and dissolved organic carbon analysis, volatile component determination by gas chromatography-mass spectrometry, and microbiological examination of low-background-flora water samples.
Accreditation Details
Accreditation Body
RvA
Number
L479
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official RvA records.
Download Scope PDFSend an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.
Test Capabilities (14)
| Standard Reference | Description | Category |
|---|---|---|
| ISO 8245 | AP16 based on ISO 8245:1999 using | Drinking Water Analysis |
| NEN 6271 | NEN 6271 | Drinking Water Analysis |
| EN 1484 | DIN EN 1484 | Elemental Analysis |
| NEN 6263 | NEN 6263 | Elemental Analysis |
| NEN-EN-ISO 10523 | DIN EN ISO 10523 | Elemental Analysis |
| ISO 10705-2 | ISO 10705-2 | Environmental / Surface Water |
| ISO 7027-1 | BS EN ISO 7027-1:2016 | Environmental / Surface Water |
| NEN 6567 | NEN 6567 | Food Microbiology |
| ISO 6222 | ISO 6222 | Food Safety Testing |
| ISO 7899-2 | ISO 7899-2 | Food Safety Testing |
| ISO 9308-1 | ISO 9308-1 | Food Safety Testing |
| NEN-EN-ISO 11731 | ISO 11731 | Food Safety Testing |
| ISO 10705-1 | ISO 10705-1 | Legionella / Microbiological |
| NEN 6254 | NEN 6254 | Temperature / Pressure |