Official name: Ministero dell'agricoltura, della sovranità alimentare e delle foreste - Dipartimento dell'Ispettorato Centrale della tutela della Qualità e della Repressione Frodi dei Prodotti Agroalimentari MASAF - ICQRF Laboratorio di Modena
Send one structured enquiry and we chase the reply for you. No cold email, no chasing.
Details
Modena 41124 , Italy
Accreditation
Tests wines, vinegars, meat products, and poultry carcasses for composition parameters including total acidity, alcoholic strength, moisture content, protein, fat, and nitrogen using titration, densimetry, and calculation methods.
Accreditation Details
Accreditation Body
ACCREDIA
Number
00204
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official ACCREDIA records.
Download Scope PDF
Test Capabilities (45)
| Standard Reference | Description | Category |
|---|---|---|
| ISO 9231 (2008) | ISO 9231 | Contaminants / Heavy Metals |
| UNI 11299 (2008) | UNI 11299 | Contaminants / Heavy Metals |
| ISO 1442 (2023) | on BS ISO 1442:2023 | Electromagnetic |
| ISO 936 (1998) | ISO 936:1998 | Electromagnetic |
| ISO 1443 (1973) | ISO 1443 | Elemental Analysis |
| ISO 937 (2023) | ISO 937 | Elemental Analysis |
| UNI EN 16965 (2018) | UNI EN 16965 | Elemental Analysis |
| UNI EN ISO 23319 (2022) | DIN EN ISO 23319 | Elemental Analysis |
| EN 1482-2 (2024) | NF EN 1482-2 | Food & Agriculture |
| ISO 23319 (2022) | ISO 23319 | Nutritional Analysis |
| ISO 3496 (1994) | F22 1 based on ISO 3496:1994(E) | Nutritional Analysis |
| ISO 5534 (2004) | ISO 5534 | Nutritional Analysis |
| ISO 6869 (2000) | ISO 6869 | Nutritional Analysis |
| UNI EN 15475 (2009) | DIN EN 15475 | Nutritional Analysis |
| DM 06/01/1979 SO GU n 67 08/03/1979 All B p.to 1 | DM 06/01/1979 SO GU n 67 08/03/1979 All B p.to 1 | Other |
| DM 10/04/1996 GU n 135 11/06/1996 | DM 10/04/1996 GU n 135 11/06/1996 | Other |
| DM 12/03/1986 SO GU n 161 14/07/1986 Met II pag 93 | DM 12/03/1986 SO GU n 161 14/07/1986 Met II pag 93 | Other |
| DM 21/04/1986 SO GU n 229 02/10/1986 Met 10 | DM 21/04/1986 SO GU n 229 02/10/1986 Met 10 | Other |
| DM 21/04/1986 SO GU n 229 02/10/1986 Met 6 | DM 21/04/1986 SO GU n 229 02/10/1986 Met 6 | Other |
| DM 21/09/1967 GU n 285 15/11/1967 | DM 21/09/1967 GU n 285 15/11/1967 | Other |
| DM 23/07/1994 SO 4 GU n 186 10/08/1994 All pag 5 | DM 23/07/1994 SO 4 GU n 186 10/08/1994 All pag 5 | Other |
| DM 25/07/2003 GU n 185 11/08/2003 | DM 25/07/2003 GU n 185 11/08/2003 | Other |
| DM 27/05/1985 suppl 3 GU n 145 21/06/1985 All | DM 27/05/1985 suppl 3 GU n 145 21/06/1985 All | Other |
| ISO 1442 (2023) | ISO 1442 | Other |
| ISO 3496 (1994) | ISO 3496 | Other |
| OIV-MA-AS2-01 Met B R2021 | OIV-MA-AS2-01 Met B R2021 | Other |
| OIV-MA-AS2-02 R2012 | OIV-MA-AS2-02 R2012 | Other |
| OIV-MA-AS2-03B R2012 | OIV-MA-AS2-03B R2012 | Other |
| OIV-MA-AS311-03 R2016 | OIV-MA-AS311-03 R2016 | Other |
| OIV-MA-AS312-01 Met B R2021 | OIV-MA-AS312-01 Met B R2021 | Other |
| OIV-MA-AS313-01 cap 5.2 R2015 | OIV-MA-AS313-01 cap 5.2 R2015 | Other |
| OIV-MA-AS313-02 R2015 | OIV-MA-AS313-02 R2015 | Other |
| OIV-MA-AS322-06 R2009 | OIV-MA-AS322-06 R2009 | Other |
| OIV-MA-AS323-04B R2009 | OIV-MA-AS323-04B R2009 | Other |
| Reg CE 152/2009 27/01/2009 GU CE | Reg CE 152/2009 27/01/2009 GU CE | Other |
| Reg UE 344/2026 26/10/2025 GU UE | Reg UE 344/2026 26/10/2025 GU UE | Other |
| Reg UE 771/2024 29/02/2024 GU UE | Reg UE 771/2024 29/02/2024 GU UE | Other |
| UNI EN 15475 (2009) | UNI EN 15475 | Other |
| UNI EN 15959 (2024) | UNI EN 15959 | Other |
| UNI EN 16197 (2013) | UNI EN 16197 | Other |
| UNI EN 16965 (2018) | UNI EN 16965 | Other |
| CEI EN 61482-2 (2020) | DIN EN 61482-2 | Physical Properties |
| ISO 27105 (2016) | ISO 27105 | Spectroscopy (XRF, ICP, AAS) |
| UNI EN 15959 (2024) | DIN EN 15959 | Spectroscopy (XRF, ICP, AAS) |
| UNI EN 16197 (2013) | DIN EN 16197 | Spectroscopy (XRF, ICP, AAS) |
Send an Enquiry