S.C.I. SERVICIOS DE CONTROL E INSPECCIÓN, S.A. (Unipersonal)
76 capabilities
Verified Apr 2026
One of 1,173 in Spain
Details
Ctra. Ajalvir - Torrejón, Km. 1,8. P. I. Los Madroños 2 - 4
Ajalvir 28864 , Spain
Ajalvir 28864 , Spain
Accreditation
Active
ENAC
LE101
Provides comprehensive non-destructive testing services including ultrasonic, radiographic, penetrant, and magnetic particle testing of metallic materials and welds, with capabilities across multiple facility locations.
Accreditation Details
Accreditation Body
ENAC
Number
LE101
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official ENAC records.
Download Scope PDFSend an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.
Test Capabilities (76)
| Standard Reference | Description | Category |
|---|---|---|
| ASTM E10 | ASTM E 10 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E18-17 | ASTM E 18-17 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E92 | ASTM E 92 | Hardness (Vickers, Rockwell, Brinell) |
| UNE EN ISO 6506-1 | UNE-EN ISO 6506-1 | Hardness (Vickers, Rockwell, Brinell) |
| UNE EN ISO 6507-1 | UNE-EN ISO 6507-1 | Hardness (Vickers, Rockwell, Brinell) |
| UNE EN ISO 6508-1 | UNE-EN ISO 6508-1 | Hardness (Vickers, Rockwell, Brinell) |
| UNE EN ISO 9015-1 | UNE-EN ISO 9015-1 | Hardness (Vickers, Rockwell, Brinell) |
| UNE-EN ISO 7438 | UNE-EN ISO 7438 | Hardness (Vickers, Rockwell, Brinell) |
| ASTM E23 | ASTM E 23 | Impact / Charpy / Izod |
| UNE EN ISO 148-1 | UNE-EN ISO 148-1 | Impact / Charpy / Izod |
| UNE EN ISO 9016 | UNE-EN ISO 9016 | Impact / Charpy / Izod |
| ASTM E505 | ASTM E505 | Magnetic Particle (MT) |
| ASTM E709 | ASTM E709 | Magnetic Particle (MT) |
| UNE EN ISO 23277 | UNE-EN ISO 23277 | Magnetic Particle (MT) |
| UNE-EN ISO 13588 | UNE-EN ISO 13588 | Magnetic Particle (MT) |
| UNE-EN ISO 9934-1 | UNE-EN ISO 9934-1 | Magnetic Particle (MT) |
| UNE-EN ISO 9934-2 | UNE-EN ISO 9934-2 | Magnetic Particle (MT) |
| UNE EN ISO 10042 | UNE-EN ISO 10042 | Non-Destructive Testing (NDT) |
| UNE EN ISO 5817 | UNE-EN ISO 5817 | Non-Destructive Testing (NDT) |
| UNE-EN 13445-5 | UNE-EN 13445-5 | Non-Destructive Testing (NDT) |
| UNE-EN 13458-2 | UNE-EN 13458-2 | Non-Destructive Testing (NDT) |
| UNE-EN 13530-2 | UNE-EN 13530-2 | Non-Destructive Testing (NDT) |
| UNE-EN 1369 | UNE-EN 1369 | Non-Destructive Testing (NDT) |
| UNE-EN 14015 | UNE-EN 14015 | Non-Destructive Testing (NDT) |
| UNE-EN ISO 10675-1 | UNE-EN ISO 10675-1 | Non-Destructive Testing (NDT) |
| UNE-EN ISO 10675-2 | UNE-EN ISO 10675-2 | Non-Destructive Testing (NDT) |
| UNE-EN ISO 15614-01 | UNE-EN ISO 15614-01 | Non-Destructive Testing (NDT) |
| UNE-EN ISO 9606-3 | UNE-EN ISO 9606-3 | Non-Destructive Testing (NDT) |
| UNE-EN ISO 9606-4 | UNE-EN ISO 9606-4 | Non-Destructive Testing (NDT) |
| UNE-EN ISO 9606-5 | UNE-EN ISO 9606-5 | Non-Destructive Testing (NDT) |
| ASTM E446 | ASTM E446 | Penetrant Testing (PT) |
| EN ISO 17637 | DIN EN ISO 17637 | Penetrant Testing (PT) |
| ISO 23279 | UNE-EN ISO 23279 | Penetrant Testing (PT) |
| UNE EN ISO 17638 | UNE-EN ISO 17638 | Penetrant Testing (PT) |
| UNE EN ISO 23278 | UNE-EN ISO 23278 | Penetrant Testing (PT) |
| UNE EN ISO 3452-1 | UNE-EN ISO 3452-1 | Penetrant Testing (PT) |
| UNE-EN ISO 10863 | UNE-EN ISO 10863 | Penetrant Testing (PT) |
| UNE-EN ISO 15614 | UNE-EN ISO 15614 | Penetrant Testing (PT) |
| UNE-EN ISO 9606-1 | UNE-EN ISO 9606-1 | Penetrant Testing (PT) |
| UNE-EN ISO 9606-2 | UNE-EN ISO 9606-2 | Penetrant Testing (PT) |
| ASTM E186 | ASTM E186 | Radiographic Testing (RT) |
| ASTM E280 | ASTM E280 | Radiographic Testing (RT) |
| EN 12732 | NEN-EN 12732 | Radiographic Testing (RT) |
| UNE EN 12797 | UNE EN 12797 | Radiographic Testing (RT) |
| UNE EN ISO 17639 | UNE-EN ISO 17639 | Radiographic Testing (RT) |
| UNE-EN 10160 | UNE-EN 10160 | Radiographic Testing (RT) |
| UNE-EN 12799 | UNE-EN 12799 | Radiographic Testing (RT) |
| UNE-EN 1371-1 | UNE-EN 1371-1 | Radiographic Testing (RT) |
| UNE-EN 1866-2 | UNE-EN 1866-2 | Radiographic Testing (RT) |
| UNE-EN ISO 17636-1 | UNE-EN ISO 17636-1 | Radiographic Testing (RT) |
| UNE-EN ISO 17636-2 | UNE-EN ISO 17636-2 | Radiographic Testing (RT) |
| UNE-EN ISO 19285 | UNE-EN ISO 19285 | Radiographic Testing (RT) |
| ASTM A370 | ASTM A 370 | Tensile / Compression / Flexural |
| ASTM E190 | ASTM E 190 | Tensile / Compression / Flexural |
| ASTM E290 | ASTM E290 | Tensile / Compression / Flexural |
| ASTM E8 | ASTM E 8 | Tensile / Compression / Flexural |
| UNE 7364 | UNE 7364 | Tensile / Compression / Flexural |
| UNE EN ISO 4136 | UNE-EN ISO 4136 | Tensile / Compression / Flexural |
| UNE EN ISO 5173 | UNE-EN ISO 5173 | Tensile / Compression / Flexural |
| UNE EN ISO 6892-1 | UNE-EN ISO 6892-1 | Tensile / Compression / Flexural |
| UNE EN ISO 9017 | UNE-EN ISO 9017 | Tensile / Compression / Flexural |
| UNE-EN ISO 15614-1 | UNE-EN ISO 15614-1 | Tensile / Compression / Flexural |
| UNE-EN ISO 15614-2 | UNE-EN ISO 15614-2 | Tensile / Compression / Flexural |
| ASTM E164 | ASTM E 164 | Ultrasonic Testing (UT) |
| ASTM E1961 | ASTM E1961 | Ultrasonic Testing (UT) |
| ASTM E2700 | ASTM E2700 | Ultrasonic Testing (UT) |
| ASTM E797 | ASTM E 797 | Ultrasonic Testing (UT) |
| ASTM E94 | ASTM E94 | Ultrasonic Testing (UT) |
| ISO 10863 | ÖNORM EN ISO 10863 | Ultrasonic Testing (UT) |
| ISO 13588 | ÖNORM EN ISO 13588 | Ultrasonic Testing (UT) |
| ISO 15626 | BS EN ISO 15626:2018 | Ultrasonic Testing (UT) |
| ISO 17640 | ÖNORM EN ISO 17640 | Ultrasonic Testing (UT) |
| UNE EN ISO 11666 | UNE-EN ISO 11666 | Ultrasonic Testing (UT) |
| UNE EN ISO 17640 | UNE-EN ISO 17640 | Ultrasonic Testing (UT) |
| UNE-EN ISO 15626 | UNE-EN ISO 15626 | Ultrasonic Testing (UT) |
| UNE-EN ISO 18279 | UNE-EN ISO 18279 | Ultrasonic Testing (UT) |