S.T.A. Srl
13 capabilities
Verified Apr 2026
One of 1,409 in Italy
Details
Via della Concordia 4
San Martino Buon Albergo 37036 , Italy
San Martino Buon Albergo 37036 , Italy
Accreditation
Active
ACCREDIA
02088
Conducts electromagnetic immunity testing of electrical and electronic equipment for residential, commercial, and industrial environments, focusing on electrostatic discharge, burst, and surge protection up to 32A power supply ports.
Accreditation Details
Accreditation Body
ACCREDIA
Number
02088
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official ACCREDIA records.
Download Scope PDFSend an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.
Test Capabilities (13)
| Standard Reference | Description | Category |
|---|---|---|
| CEI EN 61000-4-2 (2011) | 1.4 Electrostatic Discharge EN 61000-4-2 :2009 | EMC / EMI Testing |
| CEI EN 61000-4-4 (2013) | 1.5 Electrical Fast Burst Transient EN 61000-4-4:2012 | EMC / EMI Testing |
| CEI EN 61000-4-5 (2016) | 1.6 Voltage Surge Immunity EN 61000-4-5:2014 +A1:2017 | EMC / EMI Testing |
| CEI EN 61000-6-1 (2007) | IEC 61000-6-1 | EMC / EMI Testing |
| CEI EN 61000-6-2 (2006) | IEC 61000-6-2: 2005 | EMC / EMI Testing |
| CEI EN 61326-1 (2013) | IEC 61326-1: 2012 | EMC / EMI Testing |
| CEI EN 61547 (2010) | IEC 61547 | EMC / EMI Testing |
| CEI EN IEC 55011 (2025) | DIN EN 55011: 2018 | EMC / EMI Testing |
| CISPR 14-2 (2015) | IEC/CISPR 14-2 | EMC / EMI Testing |
| CISPR 35 (2016) | CISPR 35:2016 Excludes Table 2 clauses 2.2 & 2.3 | EMC / EMI Testing |
| EN 50370-2 (2003) | DIN EN 50370-2 | Electrical Safety |
| CEI EN 60204-1 (2018) | DIN EN 60204-1 | Product Safety (IEC 60335, IEC 62368) |
| CISPR 11 (2003) | EN 55011 / CISPR11 | Ultrasonic Testing (UT) |