SCHÜCO International KG Technology Center
44 capabilities
Accredited since August 2025
Verified Oct 2026
One of 3,209 in Germany
Send one structured enquiry and we chase the reply for you. No cold email, no chasing.
Details
Karolinenstraße 1-15
Bielefeld 33609 , Germany
Bielefeld 33609 , Germany
Accreditation
Active
DAkkS
D-K-11030-01-01
The SCHÜCO International KG Technology Center is located in Bielefeld, Germany with DAkkS accreditation and 25 testing capabilities. The facility provides testing for rail dynamic behaviour/running tests and rail braking systems.
Accreditation Details
Accreditation Body
DAkkS
Number
D-K-11030-01-01
Status
ActiveSince
26 August 2025
Accreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official DAkkS records.
Download Scope PDFAdditional scope documents
Test Capabilities (44)
| Standard Reference | Description | Category |
|---|---|---|
| Mechanische Messgrößen | Mechanische Messgrößen | Calibration |
| Durchfluss von Flüssigkeiten | − Durchfluss von Flüssigkeiten | Force / Torque |
| > 0,05 m³/h | > 0,05 m³/h | Other |
| auch Vor-Ort Kalibrierungen | auch Vor-Ort Kalibrierungen | Other |
| - Widerstandsthermometer | Railway brake handbooks (UIC 547) | Rail Braking Systems |
| -40 °C | Railway braking — urban guided transport test methods (EN 13452-2) | Rail Braking Systems |
| A) | Railway brake — magnetic track brakes (UIC 541-06) | Rail Braking Systems |
| Anzeigende | Railway braking — urban guided transport brake systems (EN 13452-1) | Rail Braking Systems |
| Durchflussmessgrößen | Railway brakes — disc brake pads (UIC 541-5) | Rail Braking Systems |
| Flüssigkeiten | Railway brakes — estimation of braking force (UIC 544-2) | Rail Braking Systems |
| Gase | Railway brakes — brake performance (UIC 544-1) | Rail Braking Systems |
| Mechanische Messgrößen | Railway brake — anti-slide device (UIC 541-05) | Rail Braking Systems |
| UIC 541-1 (2016-10) | Railway brakes — conditions for homologation (UIC 541-1) | Rail Braking Systems |
| UIC 546 (2014-10) | Railway brakes — electropneumatic brakes (UIC 546) | Rail Braking Systems |
| - sensoren, | Railway applications — vehicle reference masses (EN 15663) | Rail Dynamic Behaviour / Running Tests |
| -hygrometer | Railway overhead lines — pantograph heads type 2 (IEC 60494-2) | Rail Dynamic Behaviour / Running Tests |
| 0,05 m³/h | Railway pantographs — requirements for metro and tram pantographs (EN 50206-2) | Rail Dynamic Behaviour / Running Tests |
| 40 L/h | Railway catenary — current collection quality measurement (EN 50317) | Rail Dynamic Behaviour / Running Tests |
| Absolutdruck 800 hPa | Railway — behaviour of coach bogies (UIC 644) | Rail Dynamic Behaviour / Running Tests |
| DIN EN 12663-1 (2024-02) | Railway vehicle body structural requirements (EN 12663-1) | Rail Dynamic Behaviour / Running Tests |
| DIN EN 50206-1 (2011-02) | Railway pantographs — requirements for main line pantographs (EN 50206-1) | Rail Dynamic Behaviour / Running Tests |
| Druck −10 kPa | Railway passenger ride comfort evaluation (UIC 513) | Rail Dynamic Behaviour / Running Tests |
| Feuchte | Railway bogies — wheelsets and bogies structural requirements (EN 13749) | Rail Dynamic Behaviour / Running Tests |
| IEC 60494-1 (2013-09) | Railway overhead lines — pantograph heads (IEC 60494-1) | Rail Dynamic Behaviour / Running Tests |
| IEC 62846 (2016-10) | Railway pantographs — interaction with overhead contact line (IEC 62846) | Rail Dynamic Behaviour / Running Tests |
| Psychrometer | Railway vehicles — gauge limits (UIC 505-1) | Rail Dynamic Behaviour / Running Tests |
| UIC 519 (2004-12) | Railway wheelset design forces (UIC 519) | Rail Dynamic Behaviour / Running Tests |
| UIC 651 (2002-07) | Railway driver cab design (UIC 651) | Rail Dynamic Behaviour / Running Tests |
| - Widerstandsthermometer | − Widerstandsthermometer | Temperature / Pressure |
| Absolutdruck 800 hPa | Absolutdruck 800 hPa | Temperature / Pressure |
| Anzeigende | meter, direkt anzeigende | Temperature / Pressure |
| Druck | positiver Überdruck | Temperature / Pressure |
| Druck −10 kPa | Druck −10 kPa | Temperature / Pressure |
| Durchflussmessgrößen | Durchflussmessgrößen | Temperature / Pressure |
| Psychrometer | keine Psychrometer | Temperature / Pressure |
| Relative Feuchte | − Messgeräte für relative Feuchte | Temperature / Pressure |
| Thermometer mit | standsthermometer mit | Temperature / Pressure |
| Volumen strömender Gase | − Volumen strömender Gase | Temperature / Pressure |
| Volumendurchfluss d V /d t 0,029 m³/h | Volumendurchfluss d V /d t 0,029 m³/h | Temperature / Pressure |
| Volumendurchfluss d V /d t 240 L/h | Volumendurchfluss d V /d t 240 L/h | Temperature / Pressure |
| Volumendurchfluss d V /d t > 0,05 m³/h | Volumendurchfluss d V /d t > 0,05 m³/h | Temperature / Pressure |
| elektrische Hygrometer | elektrische Hygrometer | Temperature / Pressure |
| − Druck | − Druck | Temperature / Pressure |
| − Volumen strömender Flüssigkeiten | − Volumen strömender Flüssigkeiten | Temperature / Pressure |
Send an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.