Siemens
Official name: Siemens plc
27 capabilities
Verified Apr 2026
One of 2,381 in United Kingdom
Details
Digital Industries, Motion Control, Varey Road, Congleton
Congleton CW12 1PH , United Kingdom
Congleton CW12 1PH , United Kingdom
Accreditation
Active
UKAS
21541
Specialises in electromagnetic compatibility testing of adjustable speed electrical power drive systems, including conducted and radiated emissions testing, electrostatic discharge immunity, electrical fast transient immunity, and voltage surge immunity to CISPR and IEC standards.
Accreditation Details
Accreditation Body
UKAS
Number
21541
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official UKAS records.
Download Scope PDFSend an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.
Test Capabilities (27)
| Standard Reference | Description | Category |
|---|---|---|
| BS EN IEC 60068-2-78:2013 | IEC 60068-2-78 | Climate / Temperature Cycling |
| IEC 60068-2-1 :2007 | IEC 60068-2-1 | Climate / Temperature Cycling |
| IEC 60068-2-2 :2007 | IEC 60068-2-2 | Climate / Temperature Cycling |
| IEC 60068-2-27:1987 | IEC 60068-2-27 | Climate / Temperature Cycling |
| AS/NZS CISPR 11:2004 | AS/NZS CISPR 11:2004 | EMC / EMI Testing |
| BS EN 61000-3-12: 2005 | IEC 61000-3-12: 2011 | EMC / EMI Testing |
| BS EN 61000-3-2: 2006 + A2 2009 | IEC 61000-3-2: 2014 | EMC / EMI Testing |
| BS EN 61000-4-11:2004 + A1 2017 | IEC 61000-4-11: 2004 | EMC / EMI Testing |
| BS EN 61000-4-29:2001 | IEC 61000-4-29: 2000 | EMC / EMI Testing |
| BS EN 61000-4-2:1995 (Amd 1 & 2) | IEC 61000-4-2: 2008 | EMC / EMI Testing |
| BS EN 61000-4-4:1995 (Amd 1) | IEC 61000-4-4: 2012 | EMC / EMI Testing |
| BS EN 61000-4-5:1995 (Amd 1 & 2) | IEC 61000-4-5: 2005 | EMC / EMI Testing |
| BS EN 61000-4-6:1996 (Amd 1 & 2) | IEC 61000-4-6: 2013 | EMC / EMI Testing |
| EN 61000-4-13:2003 | IEC 61000-4-13: 2002 | EMC / EMI Testing |
| EN 61000-4-34:2007 including | IEC 61000-4-34: 2005 | EMC / EMI Testing |
| EN 61800-3:1996 + A11:2000 | IEC 61800-3 | EMC / EMI Testing |
| EN 61800-5-2:2017, Annex E Only, Excluding Table | IEC 61800-5-2 | EMC / EMI Testing |
| IEC 60146-1-1:2009 | IEC 60146-1-1: 2009 | EMC / EMI Testing |
| IEC 61000-2-4:2002 (clause 5.2) | IEC 61000-2-4 | EMC / EMI Testing |
| IEC 61000-4-28:2009 | IEC 61000-4-28: 2000 | EMC / EMI Testing |
| IEC 61800-9-2:2017 (clause 7.7) | IEC 61800-9-2:2017 (clause 7.7) | Electrical Safety |
| Using IEC 61000-4-14:1999 | Using IEC 61000-4-14:1999 | Electromagnetic |
| IEC 60060-1:1989 (section 4&5) | DIN IEC 60060-1 | High Voltage Testing |
| IEC 61180:2016 (clause 5&6) | IEC 61180 | Product Safety (IEC 60335, IEC 62368) |
| IEC 61800-5-1:2007 +A1:2016 | IEC 61800-5-1: 2007 | Product Safety (IEC 60335, IEC 62368) |
| BS EN IEC 60068-2-30:2005 | IEC 60068-2-30 | Vibration / Shock |
| IEC 60068-2-6:1995 | IEC 60068-2-6 | Vibration / Shock |