Spezial-EMV
Official name: Spezial-EMV GmbH
50 capabilities
Accredited since July 2024
Verified Sep 2026
One of 3,103 in Germany
Send one structured enquiry and we chase the reply for you. No cold email, no chasing.
Details
Im Reihersbruch 3
St. Ingbert 66386 , Germany
St. Ingbert 66386 , Germany
Accreditation
Active
DAkkS
D-PL-22438-01-00
Provides electromagnetic compatibility and radio frequency testing, including electrostatic discharge, immunity to RF fields, and transient electrical disturbances across a broad range of frequency bands and field strengths.
Accreditation Details
Accreditation Body
DAkkS
Number
D-PL-22438-01-00
Status
ActiveSince
31 July 2024
Accreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official DAkkS records.
Download Scope PDF
Test Capabilities (50)
| Standard Reference | Description | Category |
|---|---|---|
| ISO 16750-2: 2012 | ISO 16750-2: 2012 | Climate / Temperature Cycling |
| DIN EN IEC 55014-1 | DIN EN IEC 55014-1 | EMC / EMI Testing |
| DIN EN IEC 55014-2 | DIN EN IEC 55014-2 | EMC / EMI Testing |
| DIN EN IEC 61000-3 | DIN EN IEC 61000-3 | EMC / EMI Testing |
| EN IEC 55015 (2019) | EN IEC 55015 | EMC / EMI Testing |
| IEC 60669-2-1 | IEC 60669-2-1 | EMC / EMI Testing |
| IEC 61000-3-11: 2017 | IEC 61000-3-11: 2017 | EMC / EMI Testing |
| IEC 61000-3-2: 2014 | IEC 61000-3-2: 2014 | EMC / EMI Testing |
| IEC 61000-3-3 (2013) | IEC 61000-3-3 | EMC / EMI Testing |
| IEC 61000-4-11: 2004 | IEC 61000-4-11: 2004 | EMC / EMI Testing |
| IEC 61000-4-13: 2002 | IEC 61000-4-13: 2002 | EMC / EMI Testing |
| IEC 61000-4-28: 2000 | IEC 61000-4-28: 2000 | EMC / EMI Testing |
| IEC 61000-4-29: 2000 | IEC 61000-4-29: 2000 | EMC / EMI Testing |
| IEC 61000-4-2: 2008 | IEC 61000-4-2: 2008 | EMC / EMI Testing |
| IEC 61000-4-3: 2006 | IEC 61000-4-3: 2006 | EMC / EMI Testing |
| IEC 61000-4-4: 2012 | IEC 61000-4-4: 2012 | EMC / EMI Testing |
| IEC 61000-4-5: 2005 | IEC 61000-4-5: 2005 | EMC / EMI Testing |
| IEC 61000-4-6: 2013 | IEC 61000-4-6: 2013 | EMC / EMI Testing |
| IEC 61000-4-8: 2009 | IEC 61000-4-8: 2009 | EMC / EMI Testing |
| IEC 61000-4-9: 2016 | IEC 61000-4-9: 2016 | EMC / EMI Testing |
| IEC 61000-6-1 (2005) | IEC 61000-6-1 | EMC / EMI Testing |
| IEC 61000-6-2: 2005 | IEC 61000-6-2: 2005 | EMC / EMI Testing |
| IEC 61000-6-3: 2006 | IEC 61000-6-3: 2006 | EMC / EMI Testing |
| IEC 61000-6-4: 2006 | IEC 61000-6-4: 2006 | EMC / EMI Testing |
| IEC 61000-6-8 (2020) | IEC 61000-6-8 | EMC / EMI Testing |
| IEC 610000-6-3 (2020) | IEC 610000-6-3 | EMC / EMI Testing |
| IEC 61326-1: 2012 | IEC 61326-1: 2012 | EMC / EMI Testing |
| IEC 61326-2-1: 2012 | IEC 61326-2-1: 2012 | EMC / EMI Testing |
| IEC 61326-2-2: 2012 | IEC 61326-2-2: 2012 | EMC / EMI Testing |
| IEC 61326-2-3: 2012 | IEC 61326-2-3: 2012 | EMC / EMI Testing |
| IEC 61326-3-1 (2017) | IEC 61326-3-1 | EMC / EMI Testing |
| IEC 61326-3-2 (2017) | IEC 61326-3-2 | EMC / EMI Testing |
| IEC 61547 (2009) | IEC 61547 | EMC / EMI Testing |
| IEC/CISPR 12 (2001) | IEC/CISPR 12 | EMC / EMI Testing |
| ISO 10605 (2008) | ISO 10605 | EMC / EMI Testing |
| ISO 11451-2: 2015 | ISO 11451-2: 2015 | EMC / EMI Testing |
| ISO 11451-4: 2013 | ISO 11451-4: 2013 | EMC / EMI Testing |
| ISO 11452-2: 2019 | ISO 11452-2: 2019 | EMC / EMI Testing |
| ISO 11452-4: 2020 | ISO 11452-4: 2020 | EMC / EMI Testing |
| ISO 11452-8: 2015 | ISO 11452-8: 2015 | EMC / EMI Testing |
| ISO 11452-9: 2012 | ISO 11452-9: 2012 | EMC / EMI Testing |
| ISO 7637-2 (2011) | ISO 7637-2 | EMC / EMI Testing |
| ISO 7637-3: 2016 | ISO 7637-3: 2016 | EMC / EMI Testing |
| IEC 60947-5-2 (2019-10) | IEC 60947-5-2 | Product Safety (IEC 60335, IEC 62368) |
| EN IEC 62311 (2020) | EN IEC 62311 | Radio Frequency |
| IEC 60533: 2015 | IEC 60533: 2015 | Radio Frequency |
| IEC 62479 (2010) | IEC 62479 | Radio Frequency |
| ISO 14982 (1998) | ISO 14982 | Tensile / Compression / Flexural |
| ISO 13766-1: 2018 | ISO 13766-1: 2018 | Transport / Rail Testing |
| ISO 13766-2: 2018 | ISO 13766-2: 2018 | Transport / Rail Testing |
Send an Enquiry