Provides electromagnetic compatibility and immunity testing of electrical and electronic equipment, including in vitro diagnostic medical devices, as well as environmental stress testing covering vibration, thermal cycling, humidity, and insulation resistance.
Accreditation Details
Accreditation Body
ACCREDIA
Number
01593
Status
ActiveAccreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official ACCREDIA records.
Download Scope PDF
Test Capabilities (65)
| Standard Reference | Description | Category |
|---|---|---|
| CEI EN 60068-2-1 (2007) | DIN EN-60068-2-1 | Climate / Temperature Cycling |
| CEI EN 60068-2-2 (2008) | DIN EN-60068-2-2 | Climate / Temperature Cycling |
| CEI EN 60068-2-30 (2006) | DIN EN 60068-2-30 | Climate / Temperature Cycling |
| CEI EN IEC 60068-2-1 (2025) | IEC 60068-2-1 | Climate / Temperature Cycling |
| CEI EN IEC 60068-2-2 (2025) | IEC 60068-2-2 | Climate / Temperature Cycling |
| CEI EN IEC 60068-2-78 (2025) | IEC 60068-2-78 | Climate / Temperature Cycling |
| ISO 16750-2 | ISO 16750-2: 2012 | Climate / Temperature Cycling |
| CEI EN 50121-3-2 (2017) | DIN EN 50121-3-2 | EMC / EMI Testing |
| CEI EN 50121-4 (2017) | DIN EN 50121-4 | EMC / EMI Testing |
| CEI EN 50130-4 (2012) | DIN EN 50130-4: 2015 | EMC / EMI Testing |
| CEI EN 50155 (2018) | DIN EN 50155 | EMC / EMI Testing |
| CEI EN 55014-1 (2019) | DIN EN 55014-1: 2018 | EMC / EMI Testing |
| CEI EN 55014-2 (2016) | DIN EN 55014-2: 2016 | EMC / EMI Testing |
| CEI EN 55015 (2008) | EN IEC 55015 | EMC / EMI Testing |
| CEI EN 55016-2-1 (2015) | DIN EN 55016-2-1 | EMC / EMI Testing |
| CEI EN 55016-2-3 (2017) | DIN EN 55016-2-3: 2020 | EMC / EMI Testing |
| CEI EN 55035 (2018) | DIN EN 55035: 2018 | EMC / EMI Testing |
| CEI EN 60601-1-2 (2016) | DIN EN 60601-1-2 | EMC / EMI Testing |
| CEI EN 61000-4-16 (2016) | IEC 61000-4-16: 2015 | EMC / EMI Testing |
| CEI EN 61000-4-2 (2011) | 1.4 Electrostatic Discharge EN 61000-4-2 :2009 | EMC / EMI Testing |
| CEI EN 61000-4-29 (2001) | IEC 61000-4-29: 2000 | EMC / EMI Testing |
| CEI EN 61000-4-4 (2013) | 1.5 Electrical Fast Burst Transient EN 61000-4-4:2012 | EMC / EMI Testing |
| CEI EN 61000-4-5 (2016) | 1.6 Voltage Surge Immunity EN 61000-4-5:2014 +A1:2017 | EMC / EMI Testing |
| CEI EN 61000-4-6 (2014) | IEC 61000-4-6: 2013 | EMC / EMI Testing |
| CEI EN 61000-4-8 (2013) | IEC 61000-4-8: 2009 | EMC / EMI Testing |
| CEI EN 61000-4-9 (2017) | IEC 61000-4-9: 2016 | EMC / EMI Testing |
| CEI EN 61000-6-1 (2007) | IEC 61000-6-1 | EMC / EMI Testing |
| CEI EN 61000-6-2 (2006) | IEC 61000-6-2: 2005 | EMC / EMI Testing |
| CEI EN 61000-6-3 (2007) | IEC 61000-6-3: 2006 | EMC / EMI Testing |
| CEI EN 61000-6-4 (2007) | IEC 61000-6-4: 2006 | EMC / EMI Testing |
| CEI EN 61326-1 (2013) | IEC 61326-1: 2012 | EMC / EMI Testing |
| CEI EN 61326-2-6 (2014) | DIN EN 61326-2-6 | EMC / EMI Testing |
| CEI EN 61547 (2010) | IEC 61547 | EMC / EMI Testing |
| CEI EN IEC 55014-2 (2021) | DIN EN IEC 55014-2 | EMC / EMI Testing |
| CEI EN IEC 61000-4-2 (2025) | IEC 61000-4-2: 2008 | EMC / EMI Testing |
| CEI EN IEC 61000-4-3 (2021) | IEC 61000-4-3: 2006 | EMC / EMI Testing |
| CISPR 25 (2002) | (CISPR 25:2002) Section 6 | EMC / EMI Testing |
| EN IEC 55014-1 (2021) | DIN EN IEC 55014-1 | EMC / EMI Testing |
| EN IEC 61326-2-6 (2021) | IEC 61326-2-6 | EMC / EMI Testing |
| ISO 10605 (2008) | ISO 10605 | EMC / EMI Testing |
| ISO 11452-2 | ISO 11452-2: 2019 | EMC / EMI Testing |
| ISO 11452-4 | ISO 11452-4: 2020 | EMC / EMI Testing |
| ISO 7637-2 | ISO 7637-2 | EMC / EMI Testing |
| ISO 7637-3 | ISO 7637-3: 2016 | EMC / EMI Testing |
| IEC 60092-504 (2016) | IEC 60092-504 | Installation / Wiring Testing |
| CEI EN 60945 (2003) | CEI EN 60945 | Other |
| CEI EN 61000-4-16 (2016) | CEI EN 61000-4-16 | Other |
| CEI EN 61000-4-29 (2001) | EN 61000-4-29 | Other |
| CEI EN 61000-4-4 (2013) | EN 61000-4-4 | Other |
| CEI EN 61000-4-5 (2016) | EN 61000-4-5 | Other |
| CEI EN 61000-4-8 (2013) | EN 61000-4-8 | Other |
| CEI EN 61000-4-9 (2017) | EN 61000-4-9 | Other |
| CEI EN IEC 55011 (2025) | CEI EN IEC 55011 | Other |
| CISPR 25 (2002) | CISPR 25 | Other |
| EN 54-2 (1997) | EN 54-2 | Other |
| CEI EN 60945 (2003) | IEC 60945 | Radio Frequency |
| IEC 60533 (2015) | IEC 60533: 2015 | Radio Frequency |
| EN 54-2 (1997) | DIN EN 1254-2 | Tensile / Compression / Flexural |
| CEI EN 60068-2-27 (2012) | DIN EN-60068-2-27 | Vibration / Shock |
| CEI EN 60068-2-6 (2009) | DIN EN-60068-2-6 | Vibration / Shock |
| CEI EN 60068-2-64 (2012) | DIN EN 60068-2-64 | Vibration / Shock |
| CEI EN 60068-2-78 (2002) | DIN EN 60068-2-78 | Vibration / Shock |
| CEI EN 61373 (2012) | DIN EN 61373 | Vibration / Shock |
| CEI EN IEC 60068-2-14 (2024) | IEC 60068-2-14 | Vibration / Shock |
| CEI EN IEC 60068-2-30 (2025) | IEC 60068-2-30 | Vibration / Shock |
Send an Enquiry
Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.