Wupperverband Abwasserlabor

45 capabilities Accredited since March 2026 Verified Jul 2026 One of 3,188 in Germany
Send Enquiry

Send one structured enquiry and we chase the reply for you. No cold email, no chasing.

Details

Buchenhofen
Wuppertal 42329 , Germany

Accreditation

Active DAkkS D-PL-17611-01-01

Performs physical, physicochemical, and chemical testing of wastewater, groundwater, and surface water; also conducts ecotoxicological testing with aquatic organisms and handles wastewater sampling.

Accreditation Details

Accreditation Body

DAkkS

Number

D-PL-17611-01-01

Status

Active

Since

05 March 2026

Accreditation is granted under EU Regulation 765/2008 and assessed against ISO/IEC 17025. Data sourced from official DAkkS records.

Download Scope PDF

Test Capabilities (45)

Standard Reference Description Category
DIN EN ISO 9509 (L 38) (2006-10) DIN EN ISO 9509 (L 38) Biocompatibility (ISO 10993)
DIN EN ISO 10304- 1 (D 20) (2009-07) DIN EN ISO 10304-1 (D 20) Chromatography (GC, HPLC)
DIN EN ISO 11732 (E 23) (1997-09) DIN EN ISO 11732 (E 23) Chromatography (GC, HPLC)
DIN EN ISO 15681-2 (D 46) (2005-05) DIN EN ISO 15681-2 (D 46) Chromatography (GC, HPLC)
DIN 16169 (2012-11) DIN EN 16169 Elemental Analysis
DIN 38 409-H 1 (1987-01) DIN 38409-H 1 Elemental Analysis
DIN 38406-E 5-2 (1983-10) DIN 38406-E5-2 Elemental Analysis
DIN 38409- H 41 (1980-12) DIN 38409-H 41 Elemental Analysis
DIN 38409- H 7 (2005-12) DIN 38409-H 7 Elemental Analysis
DIN 38409-H 2 (1987-03) DIN 38409-H 2 Elemental Analysis
DIN 38409-H 44 (1992-05) DIN 38409-H 44 Elemental Analysis
DIN 38414-S 12 (1986-11) DIN 38414-S 12 Elemental Analysis
DIN 38414-S 18 (1989-11) DIN 38414-S 18 Elemental Analysis
DIN EN 27888 (C8) (1993-11) DIN EN 27888 (C 8) Elemental Analysis
DIN EN 12176 (1998-06) DIN EN 12176 Elemental Analysis
DIN EN 12260 (H 34) (2003-09) DIN EN 12260 (H 34) Elemental Analysis
DIN EN 12879 (S 3a) (2001-02) DIN EN 12879 (S 3a) Elemental Analysis
DIN EN 12880 (S 2a) (2001-02) DIN EN 12880 (S 2a) Elemental Analysis
DIN EN 13346 (S 7a) (2001-04) DIN EN 13346 (S 7a) Elemental Analysis
DIN EN 1484 (H 3) (1997-08) DIN EN 1484 (H 3) Elemental Analysis
DIN EN 15933 (S 5) (2012-11) DIN EN 15933 (S 5) Elemental Analysis
DIN EN 15935 (S 33) (2012-11) DIN EN 15935 (S 33) Elemental Analysis
DIN EN 17289 (G 25) (2014-12) DIN ISO 17289 (G 25) Elemental Analysis
DIN EN 25663 (H 11) (1993-11) DIN EN 25663 (H 11) Elemental Analysis
DIN EN 5815-1 (H 50) (2020-11) DIN EN ISO 5815-1 (H 50) Elemental Analysis
DIN EN 9562 (H 14) (2005-02) DIN EN ISO 9562 (H 14) Elemental Analysis
DIN EN ISO 10523 (C 5) (1993-11) DIN EN ISO 10523 (C 5) Elemental Analysis
DIN EN ISO 15587-1 (A 31) (2002-03) DIN EN ISO 15587-1 (A 31) Elemental Analysis
DIN EN ISO 15705 (H 45) (2003-01) DIN ISO 15705 (H 45) Elemental Analysis
DIN 38402- A 30 (1998-07) DIN 38402-A 30 Environmental / Surface Water
DIN 38409-H 9-2 (1980-07) DIN 38409-H 9-2 Environmental / Surface Water
DIN EN 872 (H 33) (1996-03) DIN EN 872 (H 33) Environmental / Surface Water
DIN EN ISO 15587-2 (A 32) (2002-03) DIN EN ISO 15587-2 (A 32) Environmental / Surface Water
DIN EN ISO 11348-2 (L 52) (2009-05) DIN EN ISO 11348-2 (L 52) Food Safety Testing
DIN 16170 (2017-01) DIN EN 16170 Spectroscopy (XRF, ICP, AAS)
DIN 26777 (D 10) (1993-04) DIN EN 26777 (D 10) Spectroscopy (XRF, ICP, AAS)
DIN 6175-1 (2009-07) DIN EN 16175-1 Spectroscopy (XRF, ICP, AAS)
DIN EN 12846 (E 12) (2012-08) DIN EN ISO 12846 (E 12) Spectroscopy (XRF, ICP, AAS)
DIN EN 5814 (G 22) (2013-02) DIN EN ISO 5814 (G 22) Spectroscopy (XRF, ICP, AAS)
DIN EN 6878 (D 11) (2004-09) DIN EN ISO 6878 (D 11) Spectroscopy (XRF, ICP, AAS)
DIN EN ISO 11885 (E 22) (2009-09) DIN EN ISO 11885 (E 22) Spectroscopy (XRF, ICP, AAS)
DIN 38404- C 4 (1976-12) DIN 38404-C 4 Temperature / Pressure
DIN 38402- A 11 (2009-02) DIN 38402-A 11 Wastewater / Effluent Testing
DIN 38414-S 8 (1985-06) DIN 38414-S 8 Wastewater / Effluent Testing
DIN EN ISO 9888 (L 25) (1999-11) DIN EN ISO 9888 (L 25) Wastewater / Effluent Testing

Send an Enquiry

Request a quote, ask about capacity, or discuss your testing requirements directly with this lab.

Please select a test method from the list
Report incorrect or outdated information
0 labs selected
Compare