VDA Band 19.1
Technical cleanliness and particle contamination analysis
VDA Band 19.1 is a German automotive industry standard that defines cleanliness requirements and testing procedures for functionally relevant components in fluid circuits. It specifies sampling methods, particle extraction techniques, and contamination classification compatible with ISO 4406 codes. This standard is widely used by Tier 1 suppliers and OEMs in Germany and central Europe to verify component integrity before assembly. Accreditation to this standard demonstrates laboratory competence in precise particle quantification and adherence to stringent German automotive quality expectations.
What it measures
- Particle count and size classification (ISO 4406 compatible)
- Cleanliness class of functional components
- Surface contamination of injectors, valves, and pumps
- Acceptable contamination thresholds per application
- Particle morphology and composition
🇩🇪
DIN EN ISO 16232
🇬🇧
BS EN ISO 16232
🇫🇷
NF EN ISO 16232
🇮🇹
UNI EN ISO 16232
🇪🇸
UNE EN ISO 16232
🇳🇱
NEN EN ISO 16232
🇩🇪
DIN EN ISO 4406
🇬🇧
BS EN ISO 4406
🇫🇷
NF EN ISO 4406
🇮🇹
UNI EN ISO 4406
🇪🇸
UNE EN ISO 4406
🇳🇱
NEN EN ISO 4406
1,865
Accredited labs
17
Countries
Showing 1,801–1,825 of 1,865 labs
Winkhaus (UK)
Active
DIN EN 12046-2
DIN EN 12094-8
DIN EN 949
BS 6375-2:2009
DIN EN 950
+ 3 more
Wocken Industriepartner
Active
Parallelendmaße aus 0,5 mm
DIN EN ISO 3650:1999
Einstelldorne
Durchmesser 3 mm
Durchmesser 5 mm
+ 3 more
Wood Group UK
Active
IEC 61400-12-1
IEC 61400-12-3
IEC 61400-50
IEC 61400-12
IEC 61400-50-2
+ 3 more
Charpy impact test (ISO 148-1)
nichtselbsttätigen
elektronischen
Ersatzlastverfahren
(Staffelverfahren)
+ 1 more
WÄGETECHNIK WEHLE
Active
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
1) In den CMC sind die erweiterten Messu
Yadav Measurements Private
Active
DIN EN 55022: 2011
CISPR 22 (1997/2006/2008)
IEC/CISPR 16-2-1
CISPR 32 (2015) + A1 (2019)
AS/NZS CISPR 11:2004
+ 3 more
Z LAB Srl
Active
DIN EN ISO 11546-1
UNI EN ISO 9295
DIN EN ISO 11957
ISO 354
ISO 3741
+ 3 more
ZENTRAL-LABOR Lübecker Ärzte
Active
HbA1c
Basophile
Eosinophile
Thrombozyten
Lymphozyten
+ 3 more
ZERA GmbH Kalibrierlabor
Active
0,05 V
- Gleichstromstärke
dreiphasig 60 V; 120 V; 240 V
> 240 V
einphasig 0,002 V
+ 3 more
Wechselstromstärke 5 mA
5 mA, 10 mA, 20 mA
40 mA, 80 mA, 150 mA
240 mA, 300 mA, 480 mA
600 mA, 720 mA, 960 mA
+ 3 more
ZF Automotive UK
Active
ISO 7637-3: 2016
ISO 11452-4: 2020
ISO 11452-2: 2019
IEC/CISPR 25
ISO 11452-5: 2002
+ 3 more
Außengewinde Nenndurchmesser
zylindrische Innengewinde
− Längenmessgeräte
Längenmessmittel
Länge
+ 3 more
DIN EN ISO 4210-1
DIN EN ISO 11243
ISO 5775-1
DIN EN 16054
DIN EN 1371-1
+ 3 more
Thrombozytenfunktion
Ristocetin)
Thrombozytenaggregation
Arachidonsäure, Epinephrin, Kollagen, Ri
17-alpha-Hydroxy-Progesteron
+ 3 more
angeborener Chromosomensatz
22q11.2-Mikrodeletionssyndrom
(22q11.2)
Kopienzahlveränderungen
(Regionen laut MLPA-Kit)
+ 3 more
- Gleichspannung
Railway vehicles — specific test require
Quellen
- Gleichstromstärke
/ Messgeräte
+ 3 more
Masse oder
Konventioneller
Wägewert/
Massenormale*
Massenormale* > 100 g
+ 3 more
Angelmann-Syndrom (15q11-q13
Region)
Prader-Willi-Syndrom (15q11-q13
Ausschluss/ Nachweis mütterlicher
Zellen im pränatalen
+ 3 more
Parallelendmaße 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße * 0,5 mm
Parallelendmaße
Parallelendmaße > 100 mm
+ 3 more
Railway brake — anti-slide device (UIC 5
Messgeräte im Kraftfahrwesen
− Rollenbremsprüfstände
− Plattenbremsprüfstände
− Scheinwerfer-Einstell-Prüfsystem
+ 3 more
DIN ISO 5667-5
DIN EN ISO 19458
ISO 5667-5
ISO 19458
DIN 38402-A 13
DIN ISO 5667-5 (A 14)
DIN EN ISO 5667-3 (A 21)
DIN EN ISO 19458 (K 19)
DIN EN 1622 (B 3)
+ 3 more
ZwickRoell
Active
Absolutdruck p *
Kraftmesseinrichtungen von
Werkstoffprüfmaschinen
Acoustics — tonality assessment (DIN 456
Auflagekraft von Fallmassen
+ 3 more
aescuLabor Hamburg
Active
Thombozyten-Funktionstest
10-OH-Carbazepin
11-Deoxycorticosteron
11-Deoxycortisol
21-Deoxycortisol
+ 3 more
amedes MVZ MEDLAB Würzburg
Active
Automatisches Blutbild
Erythrozytenzahl
Hämatokrit
Hämoglobin
Hb im einzelnen Erythrozyten
+ 3 more
No matching labs found.