EN ISO 17640
Ultrasonic Non-Destructive Testing
Ultrasonic testing (UT) detects internal flaws, wall thickness, and material discontinuities in metallic and composite components without damaging them. EN ISO 17640 covers manual UT of fusion-welded joints; phased-array (PAUT) and time-of-flight diffraction (TOFD) extend the technique to automated flaw sizing. UT is essential for pressure equipment, pipelines, and structural welds.
What it measures
- Internal flaw detection (cracks, inclusions, porosity)
- Flaw location, size, and orientation
- Wall thickness measurement
- Bond integrity in bonded structures
- Weld root and fusion defects
🇧🇪
NBN EN ISO 17640
🇩🇪
DIN EN ISO 17640
🇬🇧
BS EN ISO 17640
🇫🇷
NF EN ISO 17640
🇮🇹
UNI EN ISO 17640
🇪🇸
UNE EN ISO 17640
🇳🇱
NEN EN ISO 17640
🇧🇪
NBN EN ISO 16810
🇩🇪
DIN EN ISO 16810
🇬🇧
BS EN ISO 16810
🇫🇷
NF EN ISO 16810
🇮🇹
UNI EN ISO 16810
2,943
Accredited labs
20
Countries
Showing 1–25 of 2,943 labs
1A CAL
Active
Gleichstrom- und Niederfrequenzmessgröße
- Gleichspannung
- Gleichstromstärke
- Gleichstromwiderstand
- Wechselspannung
+ 3 more
20/30 Labs
Active
DIN EN 1650
DIN EN 1656
DIN EN 1657
DIN EN 13624
DIN EN 14348
+ 3 more
21st Century Pathology
Active
Whole Blood Full blood count | 520
Whole Blood Full blood count | SOP LAB 1
A, B, O, Rh (D) | SOP LAB 11
Blood Phlebotomy | SOP LAB 03
Biochemistry examination activities | Ro
+ 3 more
29 Fleet Street
Active
Nasopharyngeal (Nose) swab Detection of
19) virus RNA specifically RdRp | SARS-C
19) virus RNA specifically RdRp | 645
Combined Nasopharyngeal & Detection of S
Oropharyngeal (Nose & Throat) (COVID19)
3-Rath Kalibrier+Prüftechnik
Active
Sound intensity — scanning method (ISO 9
Hand-arm vibration — measurement (ISO 53
Railway testing reference handbook part
messeinrichtungen von
Pendelschlagwerke und
+ 3 more
3D Service
Active
Railway braking — adhesion under braking
Koordinatenmessgeräte geräte mit einem
DEA Hexagon Metrology
Polyworks, Software von
Metrologic, Software von
+ 3 more
4-RAIL Services
Active
BS 7976-2
(HSG 248) – 2021
(PCM) based on HSG 248
E203 based on HSG 248
E200 based on HSG 248
+ 1 more
(Härteskalen HV0,01
8tree Scanner / 0 mm bis 100 mm
Laterale Größe von
Tiefenmaß/
-unterstand
+ 2 more
9 Harley Street
Active
HUMAN BODY FLUIDS Clinical Biochemistry
Alkaline Phosphatase (ALP) | Phosphate
Alkaline Phosphatase (ALP) | SOP: LAB-SO
Alanine Aminotransferase (ALT) | Absorba
Alanine Aminotransferase (ALT) | SOP: LA
+ 3 more
NF X 43-050
ISO 16000-7
FD T 90-522
FD X 46-033
DIN EN ISO 659
DIN EN ISO 10863
DIN ISO 1817
ISO 37
DIN EN ISO 3741
+ 3 more
A.Q.C. SRL
Active
DIN EN ISO 7438
DIN EN ISO 4136
DIN EN ISO 5173
DIN EN ISO 9016
DIN EN ISO 9017
+ 3 more
A.W.V. - Busse
Active
DIN EN ISO 2719
DIN EN 12879
DIN EN 12880
DIN EN ISO 19458
DIN EN 932-1
+ 3 more
-95 kPa ≤ P < -1 kPa -1 kPa ≤ P < -100 P
5 kPa ≤ P < 80 kPa 80 kPa ≤ P ≤ 120 kPa
0 MPa ≤ P ≤ 2 MPa 2 MPa < P ≤ 20 MPa 20
Punto triple del agua (0,01 °C)
Punto de fusión del hielo (0,00 °C) -80
+ 3 more
Railway overhead lines — pantograph head
- Direktanzeigende Thermometer
- Thermopaare, Thermoelemente
abs
positiver Überdruck
+ 3 more
ABLE Calibration Services
Active
PRESSURE
Hydraulic pressure (gauge)
TEMPERATURE
DC VOLTAGE
INDUCTANCE
+ 3 more
ABP Associates
Active
(HSG 248) – 2021
staining based on HSG 248
(PCM) based on HSG 248
QP23 based on HSG 248
DIN EN 932-1
DIN EN ISO 17892-4
DIN 19682-1
DIN 19682-2
DIN EN ISO 14688-2
+ 3 more
No matching labs found.