DIN 45681

Acoustics Tonality Assessment for Noise Annoyance

DIN 45681 establishes methods for detecting and assessing the tonal audibility of noise immissions, which is essential for determining noise annoyance potential and regulatory compliance. Tonal noise components (pure tones or narrow-band frequencies) are perceived as more annoying than broadband noise at equivalent sound pressure levels, making tonality assessment critical for environmental noise evaluation. The standard defines objective procedures to quantify tonality and adjust noise exposure assessments accordingly. Accreditation for this test method enables laboratories to conduct accurate environmental noise impact assessments, particularly for industrial operations, mechanical systems, and wind energy projects where tonal characteristics significantly influence regulatory requirements and resident protection.

What it measures

  • Presence and audibility of tonal components in noise
  • Frequency and sound pressure level of pure tones
  • Prominence of tonal components relative to background noise
  • Tonality-adjusted noise rating and regulatory impact
  • Narrow-band spectral analysis and tone identification
🇩🇪 DIN EN ISO 1996-1 🇬🇧 BS EN ISO 1996-1 🇫🇷 NF EN ISO 1996-1 🇮🇹 UNI EN ISO 1996-1 🇪🇸 UNE EN ISO 1996-1 🇳🇱 NEN EN ISO 1996-1
1,670 Accredited labs
18 Countries

Showing 176–200 of 1,670 labs

DAkkS D-PL-19253-01-00 Hamburg, DE
DIN 52186 ISO 21527-1 DIN EN ISO 527-3 IEC 61924-2 DIN EN 62233 + 3 more
View Profile
ACCREDIA 00518 Guarene, IT
0,2 0,003 bis 0,006 (HLA DQ8 (HLA DQB*03:02) ISO 18787 BS EN 15662 DIN EN ISO 6888-1 + 3 more
View Profile

BIOTECNAL

Active
ENAC LE582 Sant Quirze del Valles, ES
UNE-EN ISO 6579-1 UNE-EN ISO 6222 UNE-EN 26777 UNE-EN ISO 7027-1 en 31-7-79 (BOE 29-08-79) + 3 more
View Profile

BIOXAL

Active
COFRAC 1-7423 Chalon-Sur-Saône, FR
DIN EN 17387 DIN EN 13697
View Profile
DAkkS D-PL-18867-01-02 Eching am Ammersee, DE
ISO 10381-8 DIN ISO 10381-1 DIN ISO 10381-2 DIN ISO 10381-3 DIN ISO 10381-4 + 3 more
View Profile
DAkkS D-PL-19572-01-01 Bochum, DE
DIN EN ISO 6246 DIN 53160-1 DIN EN ISO 22854 (LBLS) (OMIM 611105) (c.228- DIN EN 13016-1 + 3 more
View Profile
UKAS 0578 Garston, GB
BS EN ISO 10140-2:2021 BS EN ISO 10140-3:2021 BS EN ISO 717-2:2020 ISO 7171 BS EN ISO140-3:1995 (withdrawn) + 3 more
View Profile
ACCREDIA 00662 Palermo, IT
DIN EN ISO 7730 ISO 5667-5 ISO 17604 DIN EN ISO 6888-1 ISO 8573-4 + 3 more
View Profile
UKAS 0823 Reykjavik 104, IS
Nominal value TEMPERATURE See Notes 1 to 3 TORQUE Case Manager: BC4 + 1 more
View Profile

BSRIA

Active
UKAS 1053 Bracknell, GB
ISO 11451-1 IEC 62442-1 DIN EN 16147 DIN EN 12101-3 DIN EN 14825 + 3 more
View Profile
ENAC LE378 Sant Cugat del Vallès, ES
UNE-EN 13284-2 UNE-EN 15259 UNE-EN 16911-2 UNE-EN 13284-1 UNE EN 1911 + 3 more
View Profile
UKAS 0757 Dunfermline, GB
(HSG 248) – 2021 14B based on HSG 248 DIN EN 12021 14A based on HSG 248 (PCM) based on HSG 248 + 2 more
View Profile

Balis Micro

Active
RvA L581 Boven-Leeuwen, NL
AM09 based on BS ISO 21527-1: DIN EN ISO 21528-2 DIN EN ISO 4833-2 BS ISO 15214:1998 0.95) based on BS ISO 21527-2:2008
View Profile
DAkkS D-K-15206-01-00 Oberdischingen, DE
Sound intensity — scanning method (ISO 9 Messgeräte für die Härteskale Shore A* Analoge Anzeige Railway freight wagon brake system requi + 3 more
View Profile
DAkkS D-K-20341-02-00 Bad Nenndorf, DE
Temperaturanzeigegeräte –100 °C bis - Direktanzeigende Thermometer - Thermopaare, Thermoelemente verwendete Abkürzungen:
View Profile
DAkkS D-ML-19082-01-00 Oberschleißheim, DE
Salmonella spp. Antikörper) Treponema pallidum (Lues) Thrombozytäre Antikörper dysenteriae), Vibrio cholerae + 3 more
View Profile
DAkkS D-ML-13090-01-00 Hamburg, DE
Echinococcus granulosus Echinococcus multilocularis Paragonimus uterobilateralis Ascaris lumbricoides (IgG) Brucella spp. (IgG, IgM) + 3 more
View Profile
DAkkS D-ML-13452-02-00 Berlin, DE
Hämoglobin Differentialblutbild Erythrozyten Großes Blutbild Kleines Blutbild + 3 more
View Profile
DAkkS D-ML-13452-10-00 Freiburg, DE
Okkultes Blut Großes Blutbild Kleines Blutbild Retikulozyten Thrombozyten + 3 more
View Profile
DAkkS D-ML-13452-01-01 Ingelheim, DE
2C-B 2C-I 3-Hydroxy-Bromazepam 5-Hydroxyindolessigsäure 6-Acetylcodein + 3 more
View Profile
DAkkS D-ML-13452-05-00 Jena, DE
Zelldifferenzierung Erythrozyten Großes Blutbild Hämoglobin Kleines Blutbild + 3 more
View Profile
DAkkS D-ML-13452-07-00 Mainz, DE
Hämoglobin (immunologisch) CA 125 CA 15-3 CA 19-9 CA 72-4 + 3 more
View Profile
DAkkS D-ML-13452-06-00 Moers, DE
Hämoglobin Natriumchlorid Kalium Natrium Eiweißelektrophorese: Albumin, Alpha-1-G + 3 more
View Profile
DAkkS D-ML-13322-01-00 Karlsruhe, DE
10-OH-Carbazepin 11-Deoxycortisol 17-OH-Progesteron 21-Deoxycortisol 25-OH Vitamin D2 + 3 more
View Profile
DAkkS D-ML-19774-01-01 Gießen, DE
Thrombozytenfunktion 5-Hydroxyindolessigsäure Adrenalin Amiodaron, Desmethylamiodaron Carbohydrate-deficient + 3 more
View Profile

No matching labs found.

Industries

Environmental noise assessment and regulation Renewable energy and wind turbine development Industrial operations and manufacturing HVAC and building systems acoustics Transportation and infrastructure noise control

Related Standards

  • DIN 45680 Low-frequency noise measurement and assessment
  • ISO 1996-1 Acoustics — Description, measurement and assessment of environmental noise — Part 1: Basic quantities and assessment procedures
  • DIN 45645-2 Beurteilung von Musikdarbietungen durch ihre Umgebung — Teil 2: Meßtechnik und Beurteilung

Other Test Methods