ISO 9614-1:2023
Sound Power โ Intensity Method (Discrete Points)
This test uses a sound intensity probe to measure acoustic intensity at discrete points on a measurement surface, allowing determination of sound power levels without requiring a fully anechoic environment. The intensity-based approach is effective for characterizing noise sources in semi-reverberant or field conditions where traditional pressure-based methods are unreliable. It provides directional acoustic information and is valuable for source localization and acoustic modification assessment. Accreditation ensures proper probe calibration, measurement procedures, and data processing are maintained to standards.
What it measures
- Sound intensity magnitude and direction (vector)
- Sound power level by surface integration
- A-weighted and frequency-weighted acoustic power
- Sound radiation patterns from complex sources
๐ฉ๐ช
DIN EN ISO 9614-2
๐ฌ๐ง
BS EN ISO 9614-2
๐ซ๐ท
NF EN ISO 9614-2
๐ฎ๐น
UNI EN ISO 9614-2
๐ช๐ธ
UNE EN ISO 9614-2
๐ณ๐ฑ
NEN EN ISO 9614-2
๐ฉ๐ช
DIN EN ISO 3744
๐ฌ๐ง
BS EN ISO 3744
๐ซ๐ท
NF EN ISO 3744
๐ฎ๐น
UNI EN ISO 3744
๐ช๐ธ
UNE EN ISO 3744
๐ณ๐ฑ
NEN EN ISO 3744
1,868
Accredited labs
20
Countries
Showing 126โ150 of 1,868 labs
Air Surveys
Active
(HSG 248) โ 2021
APP 7 based on HSG 248
(PCM) based on HSG 248
(PCM) based on HSG 248)
APP 15 based on HSG 248
+ 2 more
BS EN ISO 16283-1:2014+A1:2017BS EN ISO
BS EN ISO 140-4:1998
ISO 1407
ISO 7171
BS EN ISO 9972:2015
+ 1 more
(HSG 248) โ 2021
AEC 1 based on HSG 248
(PCM) based on HSG 248
AEC 6 based on HSG 248
Airbus Defence and Space
Active
- Gleichspannung
/ Messgerรคte
1 ยตV
Quellen
> 1 V
+ 3 more
Airtech Analysis
Active
(HSG 248) โ 2021
(PCM) based on HSG 248
staining based on HSG 248
(HSG 264, 2012)
Appendix 5 of HSG 227 (2004))
ISO 23351-1
ASTM E 1354
DIN EN ISO 717-1
DIN EN ISO 717-2
DIN EN ISO 3382-1
+ 3 more
BS ISO 18283:2022
ASTM D2234 (location E)
ASTM D2013 (location B)
BS ISO 5074:2015; and
ASTM D409:2016
+ 3 more
Alkali Environmental
Active
BS EN ISO 16911-1:2013 using
DIN EN 14181
DIN EN 13126-19
DIN EN 15058
DIN EN 14789
+ 3 more
Alleima
Active
DIN EN ISO 6506-1
ASTM E 10-18
DIN EN ISO 6508-1
ASTM E 18-22
DIN EN ISO 6507-1
+ 3 more
Allgรคuer Messzentrum
Active
Durchmesser 1 mm
510 mm
Rundheitsabweichung 1 mm
Parallelitรคtsabweichung
Rundheitsabweichung
+ 3 more
Allied Aerosystems
Active
DC Resistance
2.92 mm systems (continued)
DC VOLTAGE
AC CURRENT
DC Power
+ 3 more
5-Fluorouracil-Toxizitรคt (DPYD)
Cowden-Syndrom (PTEN)
Diffuses Magenkarzinom (CDH1)
Hereditรคrer Brust- und
Eierstockkrebs (HBOC), (BRCA1, BRCA2, CH
+ 3 more
Cyclosporin A
Everolimus
FK 506 (Tacrolimus)
Sirolimus
6-Methylmercaptopurin
+ 3 more
Fra(X)-Syndrom, FXTAS (FMR1)
Friedreich Ataxie (FXN)
DRPLA (ATN1)
Huntington Krankheit (HTT)
Huntington-like (TBP, JPH3)
+ 3 more
Aldosteron
11-Desoxycorticosteron
11-Desoxycortisol
17-Hydroxypregnenolon
17-Hydroxyprogesteron
+ 3 more
Amentum Clean Energy
Active
OM H-3 based on ISO 9698:2019
ISO 9696:2017 and ISO
(HSG 248) โ 2021
(PCM) based on HSG 248
staining based on HSG 248.
No matching labs found.