ISO 3740

Sound power level determination — general measurement guidelines

ISO 3740 provides overarching principles and guidelines for selecting appropriate methods to determine sound power levels of noise sources across diverse industrial and consumer applications. It establishes the framework for choosing between precision, engineering, and survey methods based on application requirements and environmental conditions. Sound power determination is essential for manufacturers complying with noise emission directives, environmental impact assessments, and product labeling regulations across the EU. ISO 17025 accreditation ensures laboratories apply correct methodologies, maintain calibrated instrumentation, and report results with documented uncertainty traceable to primary standards.

What it measures

  • Sound power level (Lw) in decibels
  • Frequency-weighted sound power (A-weighted)
  • Octave or one-third-octave band sound power
  • Sound energy levels
  • Noise source classification and categorization
🇩🇪 DIN EN ISO 3743-1 🇬🇧 BS EN ISO 3743-1 🇫🇷 NF EN ISO 3743-1 🇮🇹 UNI EN ISO 3743-1 🇪🇸 UNE EN ISO 3743-1 🇳🇱 NEN EN ISO 3743-1 🇩🇪 DIN EN ISO 3744 🇬🇧 BS EN ISO 3744 🇫🇷 NF EN ISO 3744 🇮🇹 UNI EN ISO 3744 🇪🇸 UNE EN ISO 3744 🇳🇱 NEN EN ISO 3744
1,670 Accredited labs
18 Countries

Showing 251–275 of 834 labs

DAkkS D-K-21494-01-00 Weiden i. d. OPf., DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO elektronische Waagen Innen- und Tiefenmaße Konventioneller + 2 more
View Profile
DAkkS D-K-18423-01-00 Aschaffenburg, DE
Ebenheitsabweichung verkörperungen z.B. platten nach DIN 876:1984 Geradheitsabweichung ebener Flächen, z.B. + 3 more
View Profile

Johs. Boss

Active
DAkkS D-K-21417-01-01 Albstadt, DE
Außengewinde Flankendurchmesser 3 mm bis 100 mm 0,5 mm bis 6 mm) unsymmetrischem Profil schiedlichen Ausgabeständen gestattet. + 3 more
View Profile
DAkkS D-ML-13135-03-01 Würzburg, DE
CD45 Percp+CD16+56+CD3 CD4 CD45 Percp+CD4+CD8 Adalimumab Anti-Adalimumab Antikörper + 3 more
View Profile

Jurjanz

Active
DAkkS D-K-15085-01-01 Schkeuditz, DE
Parallelendmaße aus 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße aus > 100 mm Messschieber für 1350 mm + 3 more
View Profile
DAkkS D-K-17233-01-00 Hochdorf-Assenheim, DE
Härteprüfmaschinen nach 100 HBW Brinell- und 226 HBW messeinrichtungen von Härteprüfmaschinen + 3 more
View Profile
DAkkS D-ML-13391-01-00 Frankfurt am Main, DE
basophile, eosinophile, Granulozyten Differenzialblutbild Erythrozyten Erythrozytenverteilungsbreite (RDW) + 3 more
View Profile
DAkkS D-PL-22093-01-00 Ratingen, DE
IEC 61000-4-2: 2008 VDE 0847-4-2 IEC 61000-4-4: 2012 VDE 0847-4-4 IEC 61000-4-5: 2005 + 3 more
View Profile
DAkkS D-PL-12091-01-01 Forchtenberg, DE
IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile
DAkkS D-K-21779-01-00 Berlin, DE
Gleichspannung 100 µV Messgeräte 220 mV > 2,2 V > 11 V > 22 V + 3 more
View Profile
DAkkS D-K-20795-01-01 Waldaschaff, DE
Railway brake — magnetic track brakes (U − Ebenheit − Geradheit − Winkelnormale auch als Vor-Ort-Kalibrierung + 3 more
View Profile
DAkkS D-PL-11068-09-00 Karlsruhe, DE
DIN EN 60034-15 VDE 0530-15 IEC 60034-15 DIN EN 60044-7 VDE 0414-44-7 + 3 more
View Profile
DAkkS D-K-11068-01-00 Eggenstein-Leopoldshafen, DE
Luftkerma/-leistung Dosis Dosisleistung
View Profile

Kern & Sohn

Active
DAkkS D-K-19408-01-01 Balingen, DE
nichtselbsttätige − Waagen Festkörpervolumen Wägewert/ Masse oder + 3 more
View Profile

Kessler QMP

Active
DAkkS D-K-15118-01-01 Friedewald, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße * Einstelldorne * 1 mm Railway maintenance — track geometry (EN + 3 more
View Profile
DAkkS D-K-22363-01-01 Wiesbaden, DE
- Gleichspannung / Messgeräte Spannungsquellen - Gleichstromstärke - Gleichstromwiderstand + 3 more
View Profile
DAkkS D-K-15127-01-01 Sindelfingen, DE
Beschleunigung* Beschleunigungsmessketten (Bezugsfrequenzen) (Mittelfrequenzbereich) Beschleunigungsaufnehmer, 0,1 m/s + 3 more
View Profile
DAkkS D-K-15181-01-01 Boxberg-Unterschüpf, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 Lehrdorne Durchmesser * 1 mm Prüfstifte + 3 more
View Profile

Kiwa

Active
DAkkS D-PL-11217-01-02 Berlin, DE
DIN EN ISO 7438 DIN 50100 ISO 9352 DIN ISO 48-4 DIN EN ISO 1675 + 3 more
View Profile

Kiwa Primara

Active
DAkkS D-PL-12089-01-01 Kaufbeuren, DE
BS 1363 DIN VDE 0620-2 DIN VDE 0620-2-1 ISO 12100: 2010 DIN EN 50124-1 + 3 more
View Profile

Klingelnberg

Active
DAkkS D-K-21339-01-00 Hückeswagen, DE
Verzahnungsmesstechnik Die nachgewiesene Verzahnung und rotationssymmetrische abgedeckten Prüfkörper mit taktiler + 3 more
View Profile
DAkkS D-PL-13430-01-00 Köln, DE
DIN EN ISO 11138-3 DIN EN ISO 11138-4 DIN EN 13959 DIN 1946-4 DIN EN ISO 19458 (K 19) + 3 more
View Profile
DAkkS D-ML-13430-01-00 Köln, DE
Thrombozytenaggregation Adrenalin, Kollagen, Ristocetin, Arachid Partielle Thromboplastinzeit Fibrinogenaktivität (derived) Lupusantikoagulantien + 3 more
View Profile
DAkkS D-ML-19856-01-00 Ingolstadt, DE
Liste aller Untersuchungsverfahren Webpräsenz des Medizinischen Laboratoriu Thrombozytenaggregation Trizyklische Antidepressiva Neuroleptika (Clozapin, Norclozapin, Ola + 3 more
View Profile
DAkkS D-ML-13265-01-00 Nürnberg, DE
Antidepressiva 1: Metabolit, Paroxetin, Fluvoxamin Antidepressiva 2: Antiepileptika: Carbazepin, Sultiam, Lamotrigin + 3 more
View Profile

No matching labs found.

Industries

Machinery and equipment manufacturing HVAC and ventilation systems Power generation equipment Construction and demolition equipment Consumer appliance manufacturers

Related Standards

  • ISO 3743-1 Acoustics — Determination of sound power levels of noise sources — Part 1: Reverberation room method
  • ISO 3744 Acoustics — Determination of sound power levels of noise sources — Engineering method using an enveloping surface
  • ISO 3745 Acoustics — Determination of sound power levels of noise sources — Precision method using an enveloping surface

Other Test Methods

0 labs selected
Compare