ISO 3747:2010
Sound Power Level — In-Situ Reference Source Method
This engineering/survey method determines sound power levels using a calibrated reference sound source to account for acoustic environmental conditions during in-situ measurements. It is particularly useful for large or immobile equipment where laboratory testing is impractical, and for on-site verification of noise compliance. The reference source approach compensates for acoustic environmental effects, improving accuracy compared to basic survey methods. Accreditation ensures proper reference source maintenance and measurement protocols are followed. This method is essential for field acceptance testing and environmental noise assessments.
What it measures
- Sound power level (Lw) referenced to 1 pW
- A-weighted and frequency-weighted sound power
- Environmental acoustic correction factors
- In-situ acoustic performance
🇩🇪
DIN EN ISO 3746
🇬🇧
BS EN ISO 3746
🇫🇷
NF EN ISO 3746
🇮🇹
UNI EN ISO 3746
🇪🇸
UNE EN ISO 3746
🇳🇱
NEN EN ISO 3746
🇩🇪
DIN EN ISO 9614-1
🇬🇧
BS EN ISO 9614-1
🇫🇷
NF EN ISO 9614-1
🇮🇹
UNI EN ISO 9614-1
🇪🇸
UNE EN ISO 9614-1
🇳🇱
NEN EN ISO 9614-1
1,670
Accredited labs
18
Countries
Showing 351–375 of 834 labs
ME-Meßsysteme
Active
Kraft 50 N
Sound power — survey method (ISO 3746)
> 200 N
Railway brake — automatic variable load
0,2 kN
+ 1 more
Temperaturmessgrößen
auch direktanzeigend 35 °C
direktanzeigende > 200 °C
auch direktanzeigend
Temperaturmessgrößen −35 °C
+ 3 more
MK-Kalibrierlabor
Active
1350 mm
Innen- und Tiefenmaße *
> 300 mm
Tiefenmessschieber * 0 mm
Höhenmessschieber * 0 mm
+ 3 more
MLL MVZ
Active
Berliner-Blau-Reaktion
Naphthylacetat-Esterase
Pappenheim-Färbung
Peroxidase-Reaktion
Schnellfärbung (Diff-Quick)
+ 3 more
DIN EN 50178: 1998
DIN EN ISO 2813
DIN EN ISO 4628-4
DIN EN ISO 10456
DIN EN ISO 12572
+ 3 more
MPA Kalibrierdienst
Active
Drehmoment * 0,2 N∙m
> 10 N∙m bis
Kalibriereinrichtungen
> 100 N∙m
Drehmomentschlüssel, 0,2 N∙m
+ 3 more
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Taupunkttemperatur
direktanzeigende > 200 °C
Widerstandssensor > 300 °C
+ 3 more
MTS Systems (Germany)
Active
Kraft (WPM)
Vibration measuring instruments — test m
nen nach DIN 51220
Länge (WPM) *)
Vibration and shock — experimental modal
+ 3 more
Großes Blutbild
Kleines Blutbild
Erythrozyten
Hämoglobin
Hämatokrit
+ 3 more
Blutzellen
Basophile Granulozyten
Basophile Granulozyten, Eosinophile Gran
Eosinophile Granulozyten, Erythrozyten,
Basophile Leukozyten, absolut
+ 3 more
Antiepileptika:
(Flecainid)
Arginin, ADMA, SDMA, Homoarginin
Bupropion / Hydroxybupropion
Cotinin, Nicotin
+ 3 more
Thrombozytenaggregation
(Multiplate)
Spezifisches Gewicht
Aceton
Benzol
+ 3 more
MVZ Düsseldorf-Centrum
Active
Vitamin A
Vitamin A, Vitamin E
Vitamin C
Vitamin B2 (FAD)
Vitamin B1
+ 3 more
MVZ GANZIMMUN
Active
16-Hydroxyestron
17-Hydroxypregnenolon
17-Hydroxyprogesteron
2-Hydroxyestron
2-Methoxyestron
+ 3 more
Homocystein
Katecholamine
Vitamin A
Vitamin B1
Vitamin B6
+ 3 more
MVZ Labor Bochum MLB
Active
MN (mononukleare Zellen)
Blutbild klein
Thrombozyten
Hämoglobin
Natriumchlorid
+ 3 more
Basophile
Eosinophile
Erythrozyten
Hämatokrit
Hämoglobin
+ 3 more
Hämoglobin
11-Desoxycorticosteron
11-Desoxycortisol
17-Hydroxyprogesteron
17-OH-Pregnenolon
+ 3 more
MVZ Labor Quade & Kollegen
Active
Thrombozytenfunktion
Carbamazepin-epoxid
Levetiracetam
Phenytoin
Pregabalin
+ 3 more
Hämoglobin, frei
Thrombozytenaggregation
Thrombozytenfunktion
(Verschlusszeit)
3-Methoxytyramin
+ 3 more
5-Hydroxyindolessigsäure, linsäure, Vani
Adrenalin
Amiodaron, Desmethylamiodaron
Clozapin, Norclozapin
Dopamin
+ 3 more
MVZ Labor Greifswald
Active
HbA1c
Retikulozyten
Leukozytendifferenzierung, Leukozyten
Blutbild (Hämatokrit, Erythrozyten, Thro
Natrium
+ 3 more
MVZ Labor Krone
Active
4-Hydroxy-Tamoxifen
4-Methyl-Aminoantipyrin
6-MAM
7-amino-Clonazepam
7-amino-Flunitrazepam
+ 3 more
No matching labs found.