ISO 3747:2010
Sound Power Level — In-Situ Reference Source Method
This engineering/survey method determines sound power levels using a calibrated reference sound source to account for acoustic environmental conditions during in-situ measurements. It is particularly useful for large or immobile equipment where laboratory testing is impractical, and for on-site verification of noise compliance. The reference source approach compensates for acoustic environmental effects, improving accuracy compared to basic survey methods. Accreditation ensures proper reference source maintenance and measurement protocols are followed. This method is essential for field acceptance testing and environmental noise assessments.
What it measures
- Sound power level (Lw) referenced to 1 pW
- A-weighted and frequency-weighted sound power
- Environmental acoustic correction factors
- In-situ acoustic performance
🇩🇪
DIN EN ISO 3746
🇬🇧
BS EN ISO 3746
🇫🇷
NF EN ISO 3746
🇮🇹
UNI EN ISO 3746
🇪🇸
UNE EN ISO 3746
🇳🇱
NEN EN ISO 3746
🇩🇪
DIN EN ISO 9614-1
🇬🇧
BS EN ISO 9614-1
🇫🇷
NF EN ISO 9614-1
🇮🇹
UNI EN ISO 9614-1
🇪🇸
UNE EN ISO 9614-1
🇳🇱
NEN EN ISO 9614-1
1,670
Accredited labs
18
Countries
Showing 576–600 of 834 labs
SysKal
Active
Hexagon Metrology Raumdiagonale von
GmbH, Wetzlar, D ≤ 1500 mm
Polyworks, Software von
InnovMetric, Lindau, D
PowerINSPECT, Software
+ 3 more
ISO 5-3
ISO 12647-1
ISO 13655
ISO 3074
DIN EN ISO 1833-4
DIN EN ISO 1833-5
DIN EN ISO 1833-6
DIN EN ISO 1833-7
+ 3 more
T&H Ingenieure
Active
DIN EN 61400-11
IEC 61400-11, Edition 2.1
DIN 45645-1
DIN 45680 Bbl. 1
TAK CERT
Active
− Scheinwerfer-Einstell-Prüfsystem
− Abgasmessgeräte für Fremdzündungsmotor
− Abgasmessgeräte für Kompressionszündun
Railway brake — magnetic track brakes (U
nur Vor-Ort-Kalibrierungen
+ 3 more
- Gleichspannung
/ Messgeräte
0,1 mV
> 220 mV
> 2,2 V
+ 3 more
TES Time Elektronik Struck
Active
Elektrische Messgrößen
Gleichstrom- und Niederfrequenzmessgröße
Railway brake — magnetic track brakes (U
− Gleichspannung
− Gleichstromstärke
+ 3 more
TESTING Bluhm & Feuerherdt
Active
Tensile testing of metallic materials (I
Kraft (WPM) 0,1 kN
Werkstoffprüfmaschinen
Kraftmessgeräte 0,1 kN
Acoustics — tonality assessment (DIN 456
+ 1 more
TFI Aachen
Active
ISO 7176-16
ISO 8191-1
ISO 8191-2
EN ISO 11925-2
DIN EN 1021-1
+ 3 more
TIRA
Active
Kraft (WPM)
Kraftmesseinrichtungen von
Werkstoffprüfmaschinen
Acoustics — tonality assessment (DIN 456
Länge (WPM)
+ 3 more
DIN EN IEC 60068-2-13
DIN EN IEC 60068-2-52
DIN EN 60068-2-64
DIN EN 60068-2-78
DIN 53505
+ 3 more
Technische Universität Darmstadt Staatliche Materialprüfungsanstalt Mess- und Kalibriertechnik
Active
Railway braking — thermal analysis (EN 1
Railway — traction effort and braking fo
Railway vehicle dynamics — on-track test
Railway brake disc acoustic emissions (E
Railway wheel squeal and curve noise (EN
+ 3 more
Technische Universität München Institut für Medizinische Mikrobiologie, Immunologie und Hygiene
Active
Staphylokokken
Treponema pallidum (Cardiolipin
Antikörper)
Legionella spp.
Salmonellen, Shigellen, Yersinia
+ 3 more
TechnoTeam Bildverarbeitung
Active
& 2: 2008
Leuchtdichte L /
vom Typ L3 Standard
Normfarbwertanteile x , y /
LED-basierte Farb- und
+ 3 more
Taupunkttemperatur
Railway braking — urban guided transport
Widerstandssensor
–40 °C bis
> 5 °C bis
+ 3 more
TesT
Active
Kraftaufnehmer und
Kraft (WPM) *
Vibration measuring instruments — test m
maschinen nach DIN
Acoustics — tonality assessment (DIN 456
+ 3 more
Gleichspannung 0 mV
Messgeräte 10 mV
Wechselspannung 0,22 mV
> 220 mV
> 2,2 V
+ 3 more
Test-Fuchs, Fritz Fuchs Gesellschaft mit beschränkter Haftung Kalibrierlaboratorium Deutschland
Active
Positiver Überdruck p e
> 70 bar
Überdruck p
(ein- oder mehrgängige
Testo Industrial Services
Active
- Gleichspannung
/ Messgeräte
Quellen
Hochspannung
- Gleichstromstärke
+ 3 more
Testzentrum Baden
Active
DIN EN 60068-2-67
UNE-EN 60068-2-52
IEC/EN 60068-2-38:2009 Part 2-38:
ISO 16750-4
DIN EN 60529
+ 3 more
TetraTec Instruments
Active
Railway brakes — disc brake pads (UIC 54
Volumendurchfluss bzw.
0,01 m
Railway pantographs — requirements for m
39 mL/h
+ 3 more
Thermo Electron LED
Active
- Gleichspannung
Messgeräte 0,001 V bis
0,33 V bis
3,3 V bis
330 V bis
+ 3 more
Masse oder
Konventioneller
Wägewert/
Massenormal *)
> 1 mg
+ 3 more
No matching labs found.