ISO 3747:2010

Sound Power Level — In-Situ Reference Source Method

This engineering/survey method determines sound power levels using a calibrated reference sound source to account for acoustic environmental conditions during in-situ measurements. It is particularly useful for large or immobile equipment where laboratory testing is impractical, and for on-site verification of noise compliance. The reference source approach compensates for acoustic environmental effects, improving accuracy compared to basic survey methods. Accreditation ensures proper reference source maintenance and measurement protocols are followed. This method is essential for field acceptance testing and environmental noise assessments.

What it measures

  • Sound power level (Lw) referenced to 1 pW
  • A-weighted and frequency-weighted sound power
  • Environmental acoustic correction factors
  • In-situ acoustic performance
🇩🇪 DIN EN ISO 3746 🇬🇧 BS EN ISO 3746 🇫🇷 NF EN ISO 3746 🇮🇹 UNI EN ISO 3746 🇪🇸 UNE EN ISO 3746 🇳🇱 NEN EN ISO 3746 🇩🇪 DIN EN ISO 9614-1 🇬🇧 BS EN ISO 9614-1 🇫🇷 NF EN ISO 9614-1 🇮🇹 UNI EN ISO 9614-1 🇪🇸 UNE EN ISO 9614-1 🇳🇱 NEN EN ISO 9614-1
1,670 Accredited labs
18 Countries

Showing 151–175 of 183 labs

ENAC LC10.264 Sant Martí Sarroca, ES
(2,2 ± 0,1) ⋅ 10-2 mol/mol (99,5 ± 0,5) (15 ± 5) ⋅ 10-6 mol/mol (100 ± 5) ⋅ 10-6 (7,5 ± 0,2) ⋅ 10-2 mol/mol (15 ± 0,5) ⋅
View Profile
ENAC LC10.120 Tres Cantos, ES
5 mV ≤ U ≤ 10 V 10 V < U ≤ 1000 V 45 Hz ≤ f ≤ 60 Hz 10 mV ≤ U ≤ 10 V 10 V 100 µA ≤ I ≤ 400 mA 400 mA < I ≤ 10 A 10 300 mA ≤ I ≤ 15 A 45 Hz ≤ f ≤ 60 Hz 100 µA ≤ I ≤ 400 mA 40 + 2 more
View Profile
ENAC LC10.178 Madrid, ES
CEM Ed
View Profile
ENAC LC10.069 Sant Celoni, ES
0,03 · 10-2 mol/mol  C < 0,3 · 10-2 mol 0,3 · 10-2 mol/mol  C  1,1 · 10-2 mol/ 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 9 · 10-6 mol/mol  C < 75 · 10-6 mol/mol + 3 more
View Profile
ENAC LC10.221 Terrassa, ES
(15 ± 1) ⋅ 10-6 mol/mol (1000 ± 50) ⋅ 10 (8 ± 0,5) ⋅ 10-2 mol/mol (1,4 ± 0,1) ⋅ 1 (3000 ± 150) ⋅ 10-6 mol/mol (9 ± 1) ⋅ 10 (80 ± 8) ⋅ 10-6 mol/mol (100 ± 8) ⋅ 10-6 mol/mol
View Profile

SEQUOPRO

Active
ENAC LC10.166 Tres Cantos, ES
0,015 l/min ≤ Q ≤ 40 l/min 0,0 · 10-9 mol/mol 20 ⋅ 10-9 mol/mol ≤ C ≤ 500 ⋅ 10-9 mol/m 0,00 · 10-6 mol/mol 0,5 ⋅10-6 mol/mol ≤ C ≤ 10 ⋅10-6 mol/mol + 3 more
View Profile
ENAC LC10.216 Palmas de Gran Canaria, ES
1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 .1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg
View Profile
ENAC LC10.191 Puerto de Santa María, ES
CEM DI-021 CEM DI-004 CEM EL-007 CEM DI-003 CEM DI-008 + 3 more
View Profile
ENAC LC10.192 Sevilla, ES
EURAMET CG-6 CEM DI-021 CEM DI-004 CEM DI-013 CEM DI-012 + 3 more
View Profile
ENAC LE011 Madrid, ES
DIN EN 61010-2-010: 2015 DIN EN 60335-2-9 IEC 61000-4-8: 2009 IEC 61010-2-010: 2014 DIN EN 61010-2-101 + 3 more
View Profile
ENAC LE1992 Valladolid, ES
UNE-EN 13032-1 UNE-EN 13032-4 UNE-EN 62722-2-1 IEC 62722-2-1 IEC 62717 + 1 more
View Profile
ENAC LE1591 Valencia, ES
UNE-EN ISO 16283-1 UNE-EN ISO 16283-3 UNE-EN ISO 16283-2
View Profile
ENAC LC10.203 Zaragoza, ES
-95 kPa ≤ P < 0 kPa 0 kPa ≤ P ≤ 1 kPa 1 -95 kPa ≤ P ≤ -5 kPa - 5 kPa < P < -1 kP
View Profile
ENAC LC10.210 Cornellà de Llobregat, ES
(5 ± 0,2) · 10-2 mol/mol (1000 ± 50) · 10-6 mol/mol (15 ± 2) · 10-6 mol/mol
View Profile
ENAC LE2749 Zaragoza, ES
UNE-EN 12341 0,015 l/min ≤ Q ≤ 50 l/min 20 ⋅ 10-9 mol/mol ≤ C ≤ 500 ⋅ 10-9 mol/m 20 ⋅10-9 mol/mol ≤ C ≤ 100 ⋅ 10-9 mol/mo 100 ⋅ 10-9 mol/mol ≤ C ≤ 1000 ⋅ 10-9 mol + 3 more
View Profile
ENAC LE110 Ripoll, ES
ISO 13347-3 BS EN ISO 5801:2008 method ISO 14695
View Profile
ENAC LE1615 Gandia, ES
UNE-EN ISO 140-5 UNE-EN ISO 16283-3 UNE-EN ISO 16283-2 UNE-EN ISO 140-7 UNE-EN ISO 16283-1 + 1 more
View Profile

TECYGES

Active
ENAC LC10.232 Zaragoza, ES
CEM Procedimiento
View Profile
ENAC LE1242 Valencia, ES
UNE-EN ISO 16283-3 DIN EN ISO 16283-1 UNE-EN ISO 3382-2 BS EN ISO 16283-2:2020
View Profile
ENAC LE2333 Castellgalí, ES
DIN EN 16615 DIN EN 17658 DIN EN 13697 IEC 60127-6 DIN EN 13727 + 3 more
View Profile
ENAC LC10.184 Montmeló, ES
UNE-EN 60942 UNE-EN 61672-3 UNE-EN 60804 UNE-EN 60651 UNE-EN 61252 + 3 more
View Profile
ENAC LC10.078 Illescas, ES
UNE-EN ISO 868 ASTM D 2240 ISO 48-9 UNE 7050-3 UNE-EN ISO 10360-2 + 3 more
View Profile
ENAC LC10.182 Zamudio, ES
UNE-EN 61672-3 UNE-EN 60651 UNE-EN 60804 UNE-EN 61252 (Técnica calibrador acústic UNE-EN 60942 + 3 more
View Profile
ENAC LE2354 Noáin, ES
UNE-EN 60903 UNE-EN IEC 61243-1 UNE-EN 50508 UNE 204001 UNE-EN 61111 + 2 more
View Profile

UNIMETRIK

Active
ENAC LC10.082 Legutiano, ES
CEM DI-007 CEM DI-021 CEM DI-004 CEM DI-018 CEM DI-002 + 3 more
View Profile

No matching labs found.

Industries

Large industrial machinery and installation testing Environmental noise assessment and monitoring Building and construction equipment Transportation and railway noise evaluation Ventilation and HVAC system commissioning

Related Standards

  • ISO 3746 Determination of sound power levels of noise sources using sound pressure — Survey method
  • ISO 9614-1 Determination of sound power levels of noise sources by sound intensity — Part 1: Measurement at discrete points
  • ISO 12639 Acoustics — Reference sound sources for in-situ calibration of sound pressure and sound intensity measurement apparatus

Other Test Methods

0 labs selected
Compare