ISO 3747:2010
Sound Power Level โ In-Situ Reference Source Method
This engineering/survey method determines sound power levels using a calibrated reference sound source to account for acoustic environmental conditions during in-situ measurements. It is particularly useful for large or immobile equipment where laboratory testing is impractical, and for on-site verification of noise compliance. The reference source approach compensates for acoustic environmental effects, improving accuracy compared to basic survey methods. Accreditation ensures proper reference source maintenance and measurement protocols are followed. This method is essential for field acceptance testing and environmental noise assessments.
What it measures
- Sound power level (Lw) referenced to 1 pW
- A-weighted and frequency-weighted sound power
- Environmental acoustic correction factors
- In-situ acoustic performance
๐ฉ๐ช
DIN EN ISO 3746
๐ฌ๐ง
BS EN ISO 3746
๐ซ๐ท
NF EN ISO 3746
๐ฎ๐น
UNI EN ISO 3746
๐ช๐ธ
UNE EN ISO 3746
๐ณ๐ฑ
NEN EN ISO 3746
๐ฉ๐ช
DIN EN ISO 9614-1
๐ฌ๐ง
BS EN ISO 9614-1
๐ซ๐ท
NF EN ISO 9614-1
๐ฎ๐น
UNI EN ISO 9614-1
๐ช๐ธ
UNE EN ISO 9614-1
๐ณ๐ฑ
NEN EN ISO 9614-1
1,868
Accredited labs
20
Countries
Showing 76โ100 of 393 labs
Babcock Marine [Rosyth]
Active
(HSG 248) โ 2021
14B based on HSG 248
DIN EN 12021
14A based on HSG 248
(PCM) based on HSG 248
+ 2 more
BeckProsper
Active
ASTM A370-24
ASTM E23-24
ASTM E 384-22
ASTM E8/E8M-24
ISO 6507-1
+ 3 more
Birmingham City Council
Active
(HSG 248) โ 2021 )
(PCM) based on HSG 248)
(PCM) based on HSG 248
staining based on HSG 248
(HSG 264, 2012)
staining based on HSG 248
(HSG 248) โ 2021
(PCM) based on HSG 248
(HSG 264:2012)
Bridgend Asbestos Services
Active
(HSG 248) โ 2021
P10.2 based on HSG 248
(PCM) based on HSG 248
British Engineering Services
Active
รNORM EN ISO 3452-1
BS 3923-1:1986(Withdrawn)
ASTM E165-23
BS 4124:1991(Withdrawn)
DIN EN 10228-3
+ 3 more
Based on ISO 10312:2019 and ISO
SOP 16 by XRD (ISO BS EN
Building Analysis & Testing
Active
BS EN ISO 16283-1:2014+A1:2017BS EN ISO
BS EN ISO 16283-2:2020
BS EN ISO 140-4:1998
BS EN ISO 717-2:2020
ISO 1407
+ 2 more
C G C Laboratory
Active
(HSG 248) โ 2021
(PCM) based on HSG 248
SOP 5, based on HSG 248
SOP 4, based on HSG 248
C.W.E. Services
Active
(HSG 264, 2012)
HSG 227 (2004))
Safety Executive guides HSG 264
(2012) and App 3 of HSG 227
(HSG 248) โ 2021
+ 3 more
DIN EN 13284-1
BS ISO 9096:2017
requirements of BS EN 15259:2007
Standard and BS EN 15259:2007
DIN EN ISO 16911-1
+ 3 more
DC VOLTAGE
DC Resistance
DC CURRENT
AC Current Generation
Generation (continued)
+ 3 more
Campbell Associates
Active
Sound Calibrators
FREQUENCY
Microphones
based:
ยฝโ & ยผโ microphones @ 250 Hz
+ 3 more
BS ISO 488:2008, 2446:2008 and
on BS 4401:Part 3:1970(1986)
BS 696-2:1989 (superseded and
BS ISO 6731:2010
ISO BS EN 3727-1:2002
+ 3 more
Electrolytes in blood serum:
Enzymes in blood serum:
(Chlamydia pneumoniae, Mycoplasma
urine:
Hormones in blood serum:
+ 1 more
Cavendish Laboratories
Active
(cdt), Deletion an Pos 117
(HSG 248) โ 2021
(PCM) based on HSG 248
BS 6068-4.12:1998 (withdrawn)
No matching labs found.