ISO 3747:2010

Sound Power Level — In-Situ Reference Source Method

This engineering/survey method determines sound power levels using a calibrated reference sound source to account for acoustic environmental conditions during in-situ measurements. It is particularly useful for large or immobile equipment where laboratory testing is impractical, and for on-site verification of noise compliance. The reference source approach compensates for acoustic environmental effects, improving accuracy compared to basic survey methods. Accreditation ensures proper reference source maintenance and measurement protocols are followed. This method is essential for field acceptance testing and environmental noise assessments.

What it measures

  • Sound power level (Lw) referenced to 1 pW
  • A-weighted and frequency-weighted sound power
  • Environmental acoustic correction factors
  • In-situ acoustic performance
🇩🇪 DIN EN ISO 3746 🇬🇧 BS EN ISO 3746 🇫🇷 NF EN ISO 3746 🇮🇹 UNI EN ISO 3746 🇪🇸 UNE EN ISO 3746 🇳🇱 NEN EN ISO 3746 🇩🇪 DIN EN ISO 9614-1 🇬🇧 BS EN ISO 9614-1 🇫🇷 NF EN ISO 9614-1 🇮🇹 UNI EN ISO 9614-1 🇪🇸 UNE EN ISO 9614-1 🇳🇱 NEN EN ISO 9614-1
1,670 Accredited labs
18 Countries

Showing 401–425 of 1,670 labs

ACCREDIA 02194 Rivoli Cascine Vica, IT
DIN EN 14790 ISO 5667-5 DIN EN 14181 DIN EN ISO 16911-1 ISO 5667-11 + 3 more
View Profile
UKAS 2546 Coventry, GB
BS EN ISO 16283-1:2014+A1:2017BS EN ISO BS EN ISO 16283-2:2020 BS EN ISO 140-4:1998 ISO 1407 BS EN ISO 9972:2015 + 1 more
View Profile
UKAS 9982 Waterside Court, GB
and Appx. 3 of HSG 227 (2004)) in Appendix 5 of HSG 227 (2004) guides HSG 264 (2012) and (HSG 264, 2012)
View Profile
COFRAC 1-7175 Oullins-Pierre-Bénite, FR
NF ISO 21438-3 NF X 43-264 NF ISO 21438-1 NF X 43-259 NF ISO 21438-2 + 3 more
View Profile

ELANOVA LAB

Active
COFRAC 1-0076 Vitry-Sur-Seine, FR
DIN ISO 1817 DIN EN 15188 DIN ISO 1431-1 DIN EN 14671 DIN EN ISO 10140-2 + 3 more
View Profile

ELLAB

Active
DAkkS D-K-20746-01-00 Bockel, DE
Taupunkttemperatur Widerstandssensor –100 °C bis > 140 °C bis > 240 °C bis + 3 more
View Profile
DAkkS D-K-15099-01-01 Königslutter am Elm, DE
- Gleichspannung Messgeräte > 0,004 V > 0,33 V > 33 V > 330 V + 3 more
View Profile

EMCCons RASEK

Active
DAkkS D-K-12067-01-01 Unterleinleiter, DE
- Gleichspannung > 0,12 V Vorverstärker > 1,2 V > 12 V > 120 V + 3 more
View Profile
ENAC LC10.206 Sant Cugat del Vallès, ES
200 kg/h ≤ m ≤ 60000 kg/h 200 l/h ≤ Q ≤ 60000 l/h 200 kg/h ≤ m ≤ 30000 kg/h 200 l/h ≤ Q ≤ 30000 l/h 700 Pa ≤ P ≤ 2 MPa + 3 more
View Profile
ENAC LE634 Navarrete, ES
UNE-EN 12211 UNE-EN 12210 UNE-EN 1026 UNE-EN 12207 UNE-EN 14608 + 3 more
View Profile

ENV Surveys

Active
UKAS 2794 Brighton, GB
staining based on HSG 248 (HSG 248) – 2021 (PCM) based on HSG 248
View Profile
ENAC LE1999 San Sebastián de los Reyes, ES
Environmental noise — determination of s ISO 20906 : 2009-12 :
View Profile
DAkkS D-K-21444-01-01 Niederstetten, DE
Railway brake — anti-slide device (UIC 5 Railway brake — magnetic track brakes (U Railway brakes — conditions for homologa Railway brakes — disc brake pads (UIC 54 − Durchfluss von Gasen + 3 more
View Profile

EPTA NORD

Active
ACCREDIA 00253 Conselve, IT
DIN CEN ISO 15216-2 ISO 19250 AOAC 2012.01 2016 DIN EN ISO 15587-1 EPA 300.1 1997 + 3 more
View Profile
ENAC LE1450 Basauri, ES
UNE-EN 12350-2 UNE-EN 12504-1 UNE-EN 12390-2 UNE-EN 12390-3 UNE-EN 12350-1 + 3 more
View Profile
ENAC LE2757 Madrid, ES
UNE-EN ISO 16283-1 UNE-EN ISO 16283-2 UNE-EN ISO 16283-3 UNE 74201 UNE-EN ISO 3382-2
View Profile
ENAC LE1853 Maliaño, ES
UNE-EN ISO 6892-1 DIN EN 10002-1 ASTM E 8 ASTM E 208 ASTM E208-06 + 3 more
View Profile

ERC Testing

Active
UKAS 23361 Leigh, GB
DIN EN 1863-1 BS EN ISO 10077-1:2006 published 2024) for BS EN DIN EN 1863-2 BS EN ISO 10077-2:2017 + 3 more
View Profile
DAkkS D-PL-14613-01-03 Dresden, DE
DIN ISO 10381-5 DIN ISO 18400-102 DIN ISO 18400-104 DIN ISO 18400-105 DIN ISO 18400-203 + 3 more
View Profile
DAkkS D-K-18808-01-01 Wendlingen, DE
Sound intensity — scanning method (ISO 9 Härteprüfmaschinen Kraft einrichtungen * Vibration measuring instruments — test m + 3 more
View Profile

ESIA

Active
ACCREDIA 00691 Napoli, IT
EPA 3005 DIN EN 12457-2 EPA 3630 EPA 3050 UNI 9432 + 3 more
View Profile

ETAS

Active
DAkkS D-K-19158-01-00 Stuttgart, DE
- Gleichspannung Quellen und Messgeräte > 1 mV bis > 10 mV bis > 100 mV bis > 10 V bis + 3 more
View Profile
COFRAC 1-1147 Sainte-Croix-En-Plaine, FR
DIN EN ISO 6888-1 0.95) based on BS ISO 21527-2:2008 DIN EN ISO 6888-2 DIN ISO 16649-2 DIN EN ISO 19020 + 3 more
View Profile
ENAC LE2182 Coslada, ES
UNE 64106 BS ISO 6731:2010 UNE-EN ISO 712 UNE-EN ISO 5534 ISO 13580 + 3 more
View Profile
COFRAC 1-1488 Saverne, FR
DIN EN ISO 14403-2 DIN ISO 11464 DIN ISO 11465 NF T90-105-2 NF T90-004 + 3 more
View Profile

No matching labs found.

Industries

Large industrial machinery and installation testing Environmental noise assessment and monitoring Building and construction equipment Transportation and railway noise evaluation Ventilation and HVAC system commissioning

Related Standards

  • ISO 3746 Determination of sound power levels of noise sources using sound pressure — Survey method
  • ISO 9614-1 Determination of sound power levels of noise sources by sound intensity — Part 1: Measurement at discrete points
  • ISO 12639 Acoustics — Reference sound sources for in-situ calibration of sound pressure and sound intensity measurement apparatus

Other Test Methods

0 labs selected
Compare