ISO 3747:2010

Sound Power Level — In-Situ Reference Source Method

This engineering/survey method determines sound power levels using a calibrated reference sound source to account for acoustic environmental conditions during in-situ measurements. It is particularly useful for large or immobile equipment where laboratory testing is impractical, and for on-site verification of noise compliance. The reference source approach compensates for acoustic environmental effects, improving accuracy compared to basic survey methods. Accreditation ensures proper reference source maintenance and measurement protocols are followed. This method is essential for field acceptance testing and environmental noise assessments.

What it measures

  • Sound power level (Lw) referenced to 1 pW
  • A-weighted and frequency-weighted sound power
  • Environmental acoustic correction factors
  • In-situ acoustic performance
🇩🇪 DIN EN ISO 3746 🇬🇧 BS EN ISO 3746 🇫🇷 NF EN ISO 3746 🇮🇹 UNI EN ISO 3746 🇪🇸 UNE EN ISO 3746 🇳🇱 NEN EN ISO 3746 🇩🇪 DIN EN ISO 9614-1 🇬🇧 BS EN ISO 9614-1 🇫🇷 NF EN ISO 9614-1 🇮🇹 UNI EN ISO 9614-1 🇪🇸 UNE EN ISO 9614-1 🇳🇱 NEN EN ISO 9614-1
1,670 Accredited labs
18 Countries

Showing 901–925 of 1,670 labs

DAkkS D-K-21443-01-00 Schmalkalden, DE
(ein- und mehrgängige zylindrische Außen- und symmetrischem und unsymmetrischem Profil) Außengewinde + 3 more
View Profile
DAkkS D-PL-11240-01-01 Bremen, DE
DIN EN 60601-2-4 IEC 60512-4-1 DIN EN 124-2 IEC 60512-4-3 DIN EN 60601-2-44 + 3 more
View Profile
UKAS 0610 Bishop's Stortford, GB
(HSG 248) – 2021 QSOP 01 based on HSG 248 (PCM) based on HSG 248 QSOP 03 based on HSG 248
View Profile
UKAS 0340 Bishop's Stortford, GB
(HSG 264, 2012) Appendix 5 of HSG 227 (2004)
View Profile
DAkkS D-ML-21457-02-00 Lehrte, DE
Aluminium Blei Eisen, Kupfer Ampicillin Cefepim + 3 more
View Profile
DAkkS D-K-21622-01-00 Unterschleißheim, DE
anteile Kohlenstoffmonoxid Kohlenstoffdioxid Methan Ethan + 3 more
View Profile
UKAS 2432 Newport, GB
(HSG 248) – 2021 staining based on HSG 248
View Profile
UKAS 9656 70 Pembroke Place, GB
accordance with (EN ISO 14644- BS EN ISO 14644-1:2015
View Profile
UKAS 29622 Chelmsford, GB
(HSG 264, 2012)
View Profile
UKAS 1119 Enfield, GB
staining based on HSG 248 (HSG 248) – 2021 (PCM) based on HSG 248
View Profile
UKAS 9681 Hextable, GB
(HSG 248) – 2021 ASB04 based on HSG 248 (PCM) based on HSG 248
View Profile
UKAS 2569 Gateshead, GB
staining based on HSG 248 (HSG 248) – 2021 (PCM) based on HSG 248 3492, ISO14966 and HSG 248 DIN EN 14629 + 3 more
View Profile
DAkkS D-K-15223-01-00 Wertheim, DE
Taupunkttemperatur Fixpunktzellen *) thermometer (SPRT) *) meter, direkt anzeigende thermometer und + 3 more
View Profile
DAkkS D-ML-14413-03-01 München, DE
Cryptococcus neoformans Cardiolipin AK Escherichia coli K1-AG Haemophilus influenzae Metromec Software AG + 3 more
View Profile
UKAS 0227 Poole, GB
Plain ring gauges (taper) Plain gap gauges (parallel) Plain plug gauges (taper) LENGTH ANGLE + 3 more
View Profile
COFRAC 1-1678 Etupes, FR
NF X43-551 ETSI EN 301 489-1 V2.2.3 2019-11 NF X 44-052 DIN EN 13284-1 DIN EN 14385 + 3 more
View Profile
COFRAC 1-6837 Lievin, FR
DIN EN 14385 NF X43-551 ETSI EN 301 489-1 V2.2.3 2019-11 IS EN 1948-1:2006 2006 DIN EN 14789 + 3 more
View Profile
ENAC LE441 Madrid, ES
UNE-EN ISO 16283-1 UNE-EN ISO 16283-2 UNE-EN ISO 16283-3 UNE-EN ISO 140-7 UNE-EN ISO 140-4 + 2 more
View Profile

MATED

Active
ACCREDIA 01130 Trento, IT
DIN EN 13180 ISO 11357-1 DIN EN IEC 62631-3-1 DIN EN IEC 62631-3-2 DIN EN IEC 60068-2-11 + 3 more
View Profile

MBS

Active
DAkkS D-PL-12159-01-00 Krefeld, DE
DIN EN ISO 16484-5 DIN EN ISO 16484-6 IEC 62386-101 IEC 62386-102 IEC 62386-103 + 3 more
View Profile

MCV

Active
ENAC LC10.124 Collbató, ES
0,005 l/min ≤ Q ≤ 50 l/min 0,5 m3/h≤ Q ≤ 2,8 m3/h 0,6 m3/h  Q  2,8 m3/h 20 m3/h  Q  30 m3/h 30 m3/h < Q  70 m3/h + 3 more
View Profile
DAkkS D-PL-19548-01-03 Waldkraiburg, DE
DIN EN 13018 DIN EN 50289-1-2 DIN EN 50289-1-3 DIN EN 50289-1-4 DIN EN 50289-1-5 + 3 more
View Profile
DAkkS D-ML-13341-01-01 Berlin, DE
17-OH-Carbazepin Amiodaron, Desmethylamiodaron Amitriptylin Clobazam Clomipramin + 3 more
View Profile
DAkkS D-K-21980-02-01 Hennigsdorf, DE
Kraft 50 N Sound power — survey method (ISO 3746) > 200 N Railway brake — automatic variable load 0,2 kN + 1 more
View Profile
DAkkS D-K-20515-01-00 Filderstadt, DE
Temperaturmessgrößen auch direktanzeigend 35 °C direktanzeigende > 200 °C auch direktanzeigend Temperaturmessgrößen −35 °C + 3 more
View Profile

No matching labs found.

Industries

Large industrial machinery and installation testing Environmental noise assessment and monitoring Building and construction equipment Transportation and railway noise evaluation Ventilation and HVAC system commissioning

Related Standards

  • ISO 3746 Determination of sound power levels of noise sources using sound pressure — Survey method
  • ISO 9614-1 Determination of sound power levels of noise sources by sound intensity — Part 1: Measurement at discrete points
  • ISO 12639 Acoustics — Reference sound sources for in-situ calibration of sound pressure and sound intensity measurement apparatus

Other Test Methods

0 labs selected
Compare