IEC 60268-16:2011
Speech Transmission Index Measurement
This test method provides an objective measure of speech intelligibility in acoustic environments using the Speech Transmission Index (STI) method. STI quantifies how well speech is transmitted through an acoustic space, accounting for noise, reverberation, and frequency distortion. The measurement is critical for evaluating communication effectiveness in public address systems, conference rooms, classrooms, and other speech-critical environments. Venues with high standards for speech clarity use this method to verify system performance and acoustic suitability. ISO 17025 accreditation ensures reliable assessment of speech intelligibility compliance with design standards.
What it measures
- Speech Transmission Index (STI) value (0-1 scale)
- Modulation transfer function across frequency bands
- Speech intelligibility rating and quality assessment
- Impact of noise and reverberation on speech clarity
- Communication effectiveness and auditory conditions
🇩🇪
DIN EN ISO 3382-2
🇬🇧
BS EN ISO 3382-2
🇫🇷
NF EN ISO 3382-2
🇮🇹
UNI EN ISO 3382-2
🇪🇸
UNE EN ISO 3382-2
🇳🇱
NEN EN ISO 3382-2
🇩🇪
DIN EN ISO 1996-2
🇬🇧
BS EN ISO 1996-2
🇫🇷
NF EN ISO 1996-2
🇮🇹
UNI EN ISO 1996-2
🇪🇸
UNE EN ISO 1996-2
🇳🇱
NEN EN ISO 1996-2
1,868
Accredited labs
20
Countries
Showing 651–675 of 906 labs
TetraTec Instruments
Active
Railway brakes — disc brake pads (UIC 54
Volumendurchfluss bzw.
0,01 m
Railway pantographs — requirements for m
39 mL/h
+ 3 more
Thermo Electron LED
Active
- Gleichspannung
Messgeräte 0,001 V bis
0,33 V bis
3,3 V bis
330 V bis
+ 3 more
Masse oder
Konventioneller
Wägewert/
Massenormal *)
> 1 mg
+ 3 more
Railway brake — magnetic track brakes (U
Kraft (WPM)
Länge (WPM)
a) nur Vor-Ort-Kalibrierungen
Vickers hardness test (ISO 6507)
+ 3 more
Trescal
Active
- Gleichspannung
/ Messgeräte
10 V; 100 V; 1000 V
> 100 mV
> 0,22 V
+ 3 more
TÜV NORD CERT
Active
IEC 61000-4-39
IEC 61000-4-3: 2006
VDE 0847-4-3
IEC 61000-4-4: 2012
VDE 0847-4-4
+ 3 more
TÜV NORD Mobilität
Active
positiven Überdruck
positiver Überdruck
- Gleichstromstärke
Kraft
Schließ- und
+ 3 more
ISO 26262-2
ISO 26262-3:
ISO 26262-4
ISO 26262-5
ISO 26262-6
+ 3 more
DIN EN 12102-1
DIN EN 12237
DIN EN 13053
DIN EN 13180
DIN EN 10306
DIN EN 1048
DIN EN 1216
DIN EN 14511-3
DIN EN 14825
+ 3 more
TÜV NORD Umweltschutz
Active
DIN ISO 16000-3
DIN ISO 16000-6
DIN ISO 16000-13
DIN ISO 16000-18
DIN ISO 16000-20
+ 3 more
TÜV Rheinland Energy & Environment GmbH Messstelle für Immissionsschutz (Environmental Protection)
Active
DIN CEN/TS 17021 (DIN SPEC 33976)
DIN EN ISO 3745
DIN EN 12102-1
DIN EN 12102-2
DIN 45635-1
+ 3 more
DIN EN 12897
DIN EN 15332
DIN SPEC 1101
DIN EN 303-5
DIN EN 13126-19
+ 3 more
TÜV Rheinland Industrie Service GmbH Prüflaboratorium Safety & Security for Automation & Grid
Active
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-6
IEC 60068-2-14
DIN EN 60068-2-14
+ 3 more
DIN EN 50178: 1998
DIN EN ISO 179-1
ISO 21527-1
ISO 21527-2
DIN EN ISO 527-3
+ 3 more
TÜV Rheinland Kraftfahrt
Active
motoren
Gaskonzentration
Kohlenstoffmonoxid CO
Kohlenstoffdioxid
Kohlenstoffdioxid CO2
+ 3 more
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-14
DIN EN 60068-2-14
IEC 60068-2-30
+ 3 more
TÜV Rheinland LGA Products
Active
DIN EN 71-10
DIN EN 62321-2*VDE 0042-1-2
DIN EN 1264-5
DIN EN 13647
DIN EN 16889
+ 3 more
TÜV SÜD Auto Service
Active
Railway wheelset design forces (UIC 519)
Rollenbremsprüfstände
Kraft
Prüfsystem
Prüfgeräte (SEP)
+ 3 more
TÜV SÜD Industrie Service
Active
DIN EN ISO 4136
DIN EN ISO 5178
DIN EN ISO 6892-2
DIN EN ISO 14273
DIN EN ISO 5173
+ 3 more
DIN 13094-1
DIN 53160
DIN EN ISO 7971-3
DIN EN 1264-5
DIN EN 61646
+ 3 more
DIN 18032-7
DIN EN 1328
DIN EN 61378-2
DIN EN ISO 16810
DIN EN 1048
+ 3 more
TÜV SÜD Product Service
Active
DIN EN 50178: 1998
IEC 62040-1
VDE 0558-510
DIN VDE 0620-1
DIN VDE 0620-2-1
+ 3 more
TÜV SÜD Product Service
Active
IEC 60335-1: 2010
VDE 0700-1
DIN EN 60335-2-2
VDE 0700-2
IEC 60335-2-2
+ 3 more
TÜV SÜD Product Service
Active
DIN EN IEC 61851
DIN EN ISO 6185-3
DIN EN 61854
DIN EN 16083
DIN EN 16051-1
+ 3 more