DIN 45669-2

Vibration Measuring Instruments Test Methods

DIN 45669-2 specifies test methods for evaluating the performance, accuracy, and reliability of vibration measuring instruments used in environmental and occupational monitoring. These tests verify that vibration meters meet metrological requirements and provide consistent, traceable measurements across different operating conditions. The standard covers calibration procedures, frequency response testing, and signal handling verification. Accreditation for this test method ensures that laboratories can validate vibration measurement equipment used in workplace assessments, structural monitoring, and machinery diagnostics. Proper instrument verification is critical for occupational health and safety compliance across industrial sectors.

What it measures

  • Frequency response accuracy of vibration sensors
  • Calibration traceability and metrological performance
  • Signal linearity and dynamic range
  • Temperature stability and environmental robustness
  • Sensor sensitivity and transducer characteristics
🇩🇪 DIN EN ISO 20816-1 🇬🇧 BS EN ISO 20816-1 🇫🇷 NF EN ISO 20816-1 🇮🇹 UNI EN ISO 20816-1 🇪🇸 UNE EN ISO 20816-1 🇳🇱 NEN EN ISO 20816-1 🇩🇪 DIN EN ISO 16063-41 🇬🇧 BS EN ISO 16063-41 🇫🇷 NF EN ISO 16063-41 🇮🇹 UNI EN ISO 16063-41 🇪🇸 UNE EN ISO 16063-41 🇳🇱 NEN EN ISO 16063-41
1,670 Accredited labs
18 Countries

Showing 151–175 of 183 labs

ENAC LC10.264 Sant Martí Sarroca, ES
(2,2 ± 0,1) ⋅ 10-2 mol/mol (99,5 ± 0,5) (15 ± 5) ⋅ 10-6 mol/mol (100 ± 5) ⋅ 10-6 (7,5 ± 0,2) ⋅ 10-2 mol/mol (15 ± 0,5) ⋅
View Profile
ENAC LC10.120 Tres Cantos, ES
5 mV ≤ U ≤ 10 V 10 V < U ≤ 1000 V 45 Hz ≤ f ≤ 60 Hz 10 mV ≤ U ≤ 10 V 10 V 100 µA ≤ I ≤ 400 mA 400 mA < I ≤ 10 A 10 300 mA ≤ I ≤ 15 A 45 Hz ≤ f ≤ 60 Hz 100 µA ≤ I ≤ 400 mA 40 + 2 more
View Profile
ENAC LC10.178 Madrid, ES
CEM Ed
View Profile
ENAC LC10.069 Sant Celoni, ES
0,03 · 10-2 mol/mol  C < 0,3 · 10-2 mol 0,3 · 10-2 mol/mol  C  1,1 · 10-2 mol/ 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 9 · 10-6 mol/mol  C < 75 · 10-6 mol/mol + 3 more
View Profile
ENAC LC10.221 Terrassa, ES
(15 ± 1) ⋅ 10-6 mol/mol (1000 ± 50) ⋅ 10 (8 ± 0,5) ⋅ 10-2 mol/mol (1,4 ± 0,1) ⋅ 1 (3000 ± 150) ⋅ 10-6 mol/mol (9 ± 1) ⋅ 10 (80 ± 8) ⋅ 10-6 mol/mol (100 ± 8) ⋅ 10-6 mol/mol
View Profile

SEQUOPRO

Active
ENAC LC10.166 Tres Cantos, ES
0,015 l/min ≤ Q ≤ 40 l/min 0,0 · 10-9 mol/mol 20 ⋅ 10-9 mol/mol ≤ C ≤ 500 ⋅ 10-9 mol/m 0,00 · 10-6 mol/mol 0,5 ⋅10-6 mol/mol ≤ C ≤ 10 ⋅10-6 mol/mol + 3 more
View Profile
ENAC LC10.216 Palmas de Gran Canaria, ES
1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 .1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg
View Profile

SAICA

Active
ENAC LC10.191 Puerto de Santa María, ES
CEM DI-021 CEM DI-004 CEM EL-007 CEM DI-003 CEM DI-008 + 3 more
View Profile

SIMETRYCAL

Active
ENAC LC10.192 Sevilla, ES
EURAMET CG-6 CEM DI-021 CEM DI-004 CEM DI-013 CEM DI-012 + 3 more
View Profile
ENAC LE011 Madrid, ES
DIN EN 61010-2-010: 2015 DIN EN 60335-2-9 IEC 61000-4-8: 2009 IEC 61010-2-010: 2014 DIN EN 61010-2-101 + 3 more
View Profile
ENAC LE1992 Valladolid, ES
UNE-EN 13032-1 UNE-EN 13032-4 UNE-EN 62722-2-1 IEC 62722-2-1 IEC 62717 + 1 more
View Profile
ENAC LE1591 Valencia, ES
UNE-EN ISO 16283-1 UNE-EN ISO 16283-3 UNE-EN ISO 16283-2
View Profile
ENAC LC10.203 Zaragoza, ES
-95 kPa ≤ P < 0 kPa 0 kPa ≤ P ≤ 1 kPa 1 -95 kPa ≤ P ≤ -5 kPa - 5 kPa < P < -1 kP
View Profile
ENAC LC10.210 Cornellà de Llobregat, ES
(5 ± 0,2) · 10-2 mol/mol (1000 ± 50) · 10-6 mol/mol (15 ± 2) · 10-6 mol/mol
View Profile
ENAC LE2749 Zaragoza, ES
UNE-EN 12341 0,015 l/min ≤ Q ≤ 50 l/min 20 ⋅ 10-9 mol/mol ≤ C ≤ 500 ⋅ 10-9 mol/m 20 ⋅10-9 mol/mol ≤ C ≤ 100 ⋅ 10-9 mol/mo 100 ⋅ 10-9 mol/mol ≤ C ≤ 1000 ⋅ 10-9 mol + 3 more
View Profile
ENAC LE110 Ripoll, ES
ISO 13347-3 BS EN ISO 5801:2008 method ISO 14695
View Profile
ENAC LE1615 Gandia, ES
UNE-EN ISO 140-5 UNE-EN ISO 16283-3 UNE-EN ISO 16283-2 UNE-EN ISO 140-7 UNE-EN ISO 16283-1 + 1 more
View Profile

TECYGES

Active
ENAC LC10.232 Zaragoza, ES
CEM Procedimiento
View Profile
ENAC LE1242 Valencia, ES
UNE-EN ISO 16283-3 DIN EN ISO 16283-1 UNE-EN ISO 3382-2 BS EN ISO 16283-2:2020
View Profile
ENAC LE2333 Castellgalí, ES
DIN EN 16615 DIN EN 17658 DIN EN 13697 IEC 60127-6 DIN EN 13727 + 3 more
View Profile
ENAC LC10.184 Montmeló, ES
UNE-EN 60942 UNE-EN 61672-3 UNE-EN 60804 UNE-EN 60651 UNE-EN 61252 + 3 more
View Profile
ENAC LC10.078 Illescas, ES
UNE-EN ISO 868 ASTM D 2240 ISO 48-9 UNE 7050-3 UNE-EN ISO 10360-2 + 3 more
View Profile
ENAC LC10.182 Zamudio, ES
UNE-EN 61672-3 UNE-EN 60651 UNE-EN 60804 UNE-EN 61252 (Técnica calibrador acústic UNE-EN 60942 + 3 more
View Profile

TESICNOR

Active
ENAC LE2354 Noáin, ES
UNE-EN 60903 UNE-EN IEC 61243-1 UNE-EN 50508 UNE 204001 UNE-EN 61111 + 2 more
View Profile

UNIMETRIK

Active
ENAC LC10.082 Legutiano, ES
CEM DI-007 CEM DI-021 CEM DI-004 CEM DI-018 CEM DI-002 + 3 more
View Profile

No matching labs found.

Industries

Occupational health and safety Manufacturing and machinery maintenance Structural engineering and civil infrastructure Environmental monitoring Calibration and metrology service providers

Related Standards

  • DIN 45669-1 Vibration measuring instruments — Part 1: Specifications for instruments
  • ISO 20816-1 Mechanical vibration — Measurement and evaluation of machine vibration — Part 1: General guidance
  • ISO 16063-41 Methods for the calibration of vibration and shock transducers — Part 41: Calibration of non-resonant accelerometers

Other Test Methods

0 labs selected
Compare