EN 13452-1:2018
Urban Guided Transport Brake Systems Performance
This test evaluates the performance requirements and safety criteria for braking systems installed on urban guided transport vehicles such as trams, light rail, and metro systems. The standard specifies maximum braking distances, deceleration rates, and reliability requirements under various operating conditions and environmental factors. Accreditation for these tests is critical as brake system failures on urban transit can result in passenger safety hazards and service disruptions affecting thousands of daily commuters.
What it measures
- Braking distance and deceleration performance
- Emergency brake response time and effectiveness
- Fade resistance and thermal stability
- Reliability and mean distance between failures
- Compatibility with vehicle control systems
🇩🇪
DIN EN 13452-2
🇬🇧
BS EN 13452-2
🇫🇷
NF EN 13452-2
🇮🇹
UNI EN 13452-2
🇪🇸
UNE EN 13452-2
🇳🇱
NEN EN 13452-2
🇩🇪
DIN EN 12663-1
🇬🇧
BS EN 12663-1
🇫🇷
NF EN 12663-1
🇮🇹
UNI EN 12663-1
🇪🇸
UNE EN 12663-1
🇳🇱
NEN EN 12663-1
1,323
Accredited labs
15
Countries
Showing 801–825 of 1,323 labs
Metrolution
Active
Metrosoft CM, Software einer Raumdiagona
AG, Chur, CH ≤ 3333 mm
Oberkochen, D
GmbH, Wetzlar, D
AG, Chur, CH ≤ 7500 mm
Mettler-Toledo
Active
Flüssigkeitsvolumen *
Kolbenhubpipetten
Manuell betätigte
spritzen
Mehrfachdispenser
+ 3 more
MeßTechnikNord
Active
- Gleichspannung
Messverstärker > 120 mV
> 1 V
> 12 V
> 1000 V
+ 3 more
Microtech Services (Wessex)
Active
ISO 7251
# = 100 A
ISO 6888-3
1) A:2b based on ISO 4833-2:2013 Amd 1:2
2) A:6c based on ISO 21528-1:2017 by mos
+ 1 more
Mimete Srl Unipersonale
Active
ASTM B212-21
ASTM E1019-24
ASTM B527-24
BS EN ISO 3923-1
ASTM B417-22
+ 3 more
Minebea Intec Bovenden
Active
Konventioneller
Wägewert/
Massenormale
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
+ 3 more
Bacillus cereus Toxin
Clostridium perfringens
Salmonella spp.
Shigella spp.
Staphylococcus aureus Toxin
+ 3 more
ETSI EN 319 412
ETSI EN 319 401
ETSI EN 319 411-2
ETSI EN 319 411-1
Railway brake — magnetic track brakes (U
auch Vor-Ort Kalibrierung
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
Mitutoyo Deutschland
Active
Parallelendmaße 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße
> 10 mm
Parallelendmaße > 100 mm
+ 3 more
Mobiler Kalibrierdienst Fini
Active
Gleichspannung 3 mV
Messgeräte 10 mV
> 100 mV
> 220 mV
> 11 V
+ 3 more
Temperatur 50 °C
Railway brake handbooks (UIC 547)
1) In den CMC sind die erweiterten Messu
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-3: 2006
VDE 0847-4-3
IEC 61000-4-4: 2012
+ 3 more
Mühlenkreiskliniken AöR Institut für Laboratoriumsmedizin, Transfusionsmedizin und Mikrobiologie
Suspended
Differentialblutbild
Kleines Blutbild (maschinell)
Thrombozyten
Unreife Thrombozyten (IPF)
Urinsediment (maschinell)
+ 3 more
München Klinik gGmbH Medizet - Institut für Laboratoriumsmedizin und medizinische Mikrobiologie
Active
Hämoglobin A1c
Hämoglobin-Differenzierung
Erythrozyten
Basophile Granolozyten
Eosinophile Granulozyten
+ 3 more
NATEC Sensors
Active
Railway brakes — conditions for homologa
− Durchfluss von Flüssigkeiten
Gleichspannung U
(Simulation des Signals
generators)
+ 3 more
2 · 10–6 mol/mol C 100 · 10–6 mol/mo
0,1 · 10–2 mol/mol < C 2,5 · 10–2 mol/
1 · 10–6 mol/mol C 100 · 10–6 mol/mo
5 · 10–6 mol/mol C 20 · 10–6 mol/mol
0,15 · 10–2 mol/mol C 20 · 10–2 mol/
+ 3 more
NMi TESTLAB
Active
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
NORMEC QS
Active
NEN-EN 13361
ISO 13362
NEN-EN 13491
DIN EN 13493
NEN-EN 13492
+ 3 more
NSF Wales Limited
Active
BS EN ISO 7686:2005
DIN EN 997
DIN EN 13079
DIN ISO 10381-7
DIN EN 14622
+ 3 more
Narda Safety Test Solutions
Active
Elektrische Feldstärke /
2 V/m
2,5 V/m
1 V/m
Magnetische Feldstärke /
+ 3 more
No matching labs found.