EN 15734-2

High-Speed Railway Braking System Performance Testing

This test method establishes performance criteria and evaluation procedures for braking systems installed on high-speed rolling stock operating at speeds exceeding 200 km/h. It assesses braking distances, deceleration rates, emergency brake effectiveness, and thermal capacity under various operational scenarios and environmental conditions. The test is essential for ensuring passenger safety and operational reliability on high-speed rail networks across Europe. Accreditation guarantees that testing laboratories can verify compliance with Technical Specifications for Interoperability (TSI) and validate that braking systems meet stringent European safety requirements.

What it measures

  • Braking distance and deceleration rates
  • Emergency brake effectiveness and response time
  • Thermal stability and fade characteristics
  • Braking system energy dissipation capacity
  • Performance consistency across repeated brake applications
🇩🇪 DIN EN 15152 🇬🇧 BS EN 15152 🇫🇷 NF EN 15152 🇮🇹 UNI EN 15152 🇪🇸 UNE EN 15152 🇳🇱 NEN EN 15152 🇩🇪 DIN EN 13571 🇬🇧 BS EN 13571 🇫🇷 NF EN 13571 🇮🇹 UNI EN 13571 🇪🇸 UNE EN 13571 🇳🇱 NEN EN 13571
1,323 Accredited labs
15 Countries

Showing 101–125 of 128 labs

ENAC LC10.077 Madrid, ES
2 · 10–6 mol/mol  C  100 · 10–6 mol/mo 0,1 · 10–2 mol/mol < C  2,5 · 10–2 mol/ 1 · 10–6 mol/mol  C  100 · 10–6 mol/mo 5 · 10–6 mol/mol  C  20 · 10–6 mol/mol 0,15 · 10–2 mol/mol  C  20 · 10–2 mol/ + 3 more
View Profile

OCA GLOBAL

Active
ENAC LE2316 Pozuelo de Alarcón, ES
UNE-EN 14385 UNE-EN 15259 UNE-EN 13211 BS ISO 9096:2017 UNE 77216 + 3 more
View Profile
ENAC LE2092 Alcázar de San Juan, ES
UNE-EN ISO/IEC 17025
View Profile
ENAC LE2055 Nigrán, ES
UNE-EN 1789
View Profile
ENAC LC10.264 Sant Martí Sarroca, ES
(2,2 ± 0,1) ⋅ 10-2 mol/mol (99,5 ± 0,5) (15 ± 5) ⋅ 10-6 mol/mol (100 ± 5) ⋅ 10-6 (7,5 ± 0,2) ⋅ 10-2 mol/mol (15 ± 0,5) ⋅
View Profile
ENAC LC10.120 Tres Cantos, ES
5 mV ≤ U ≤ 10 V 10 V < U ≤ 1000 V 45 Hz ≤ f ≤ 60 Hz 10 mV ≤ U ≤ 10 V 10 V 100 µA ≤ I ≤ 400 mA 400 mA < I ≤ 10 A 10 300 mA ≤ I ≤ 15 A 45 Hz ≤ f ≤ 60 Hz 100 µA ≤ I ≤ 400 mA 40 + 2 more
View Profile
ENAC LC10.178 Madrid, ES
CEM Ed
View Profile
ENAC LC10.069 Sant Celoni, ES
0,03 · 10-2 mol/mol  C < 0,3 · 10-2 mol 0,3 · 10-2 mol/mol  C  1,1 · 10-2 mol/ 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 9 · 10-6 mol/mol  C < 75 · 10-6 mol/mol + 3 more
View Profile
ENAC LC10.221 Terrassa, ES
(15 ± 1) ⋅ 10-6 mol/mol (1000 ± 50) ⋅ 10 (8 ± 0,5) ⋅ 10-2 mol/mol (1,4 ± 0,1) ⋅ 1 (3000 ± 150) ⋅ 10-6 mol/mol (9 ± 1) ⋅ 10 (80 ± 8) ⋅ 10-6 mol/mol (100 ± 8) ⋅ 10-6 mol/mol
View Profile

SEQUOPRO

Active
ENAC LC10.166 Tres Cantos, ES
0,015 l/min ≤ Q ≤ 40 l/min 0,0 · 10-9 mol/mol 20 ⋅ 10-9 mol/mol ≤ C ≤ 500 ⋅ 10-9 mol/m 0,00 · 10-6 mol/mol 0,5 ⋅10-6 mol/mol ≤ C ≤ 10 ⋅10-6 mol/mol + 3 more
View Profile
ENAC LC10.216 Palmas de Gran Canaria, ES
1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 .1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg
View Profile

SAICA

Active
ENAC LC10.191 Puerto de Santa María, ES
CEM DI-021 CEM DI-004 CEM EL-007 CEM DI-003 CEM DI-008 + 3 more
View Profile

SIMETRYCAL

Active
ENAC LC10.192 Sevilla, ES
EURAMET CG-6 CEM DI-021 CEM DI-004 CEM DI-013 CEM DI-012 + 3 more
View Profile
ENAC LE011 Madrid, ES
DIN EN 61010-2-010: 2015 DIN EN 60335-2-9 IEC 61000-4-8: 2009 IEC 61010-2-010: 2014 DIN EN 61010-2-101 + 3 more
View Profile
ENAC LC10.203 Zaragoza, ES
-95 kPa ≤ P < 0 kPa 0 kPa ≤ P ≤ 1 kPa 1 -95 kPa ≤ P ≤ -5 kPa - 5 kPa < P < -1 kP
View Profile
ENAC LC10.210 Cornellà de Llobregat, ES
(5 ± 0,2) · 10-2 mol/mol (1000 ± 50) · 10-6 mol/mol (15 ± 2) · 10-6 mol/mol
View Profile
ENAC LE2749 Zaragoza, ES
UNE-EN 12341 0,015 l/min ≤ Q ≤ 50 l/min 20 ⋅ 10-9 mol/mol ≤ C ≤ 500 ⋅ 10-9 mol/m 20 ⋅10-9 mol/mol ≤ C ≤ 100 ⋅ 10-9 mol/mo 100 ⋅ 10-9 mol/mol ≤ C ≤ 1000 ⋅ 10-9 mol + 3 more
View Profile

TECYGES

Active
ENAC LC10.232 Zaragoza, ES
CEM Procedimiento
View Profile
ENAC LE2333 Castellgalí, ES
DIN EN 16615 DIN EN 17658 DIN EN 13697 IEC 60127-6 DIN EN 13727 + 3 more
View Profile
ENAC LC10.078 Illescas, ES
UNE-EN ISO 868 ASTM D 2240 ISO 48-9 UNE 7050-3 UNE-EN ISO 10360-2 + 3 more
View Profile

TESICNOR

Active
ENAC LE2354 Noáin, ES
UNE-EN 60903 UNE-EN IEC 61243-1 UNE-EN 50508 UNE 204001 UNE-EN 61111 + 2 more
View Profile

UNIMETRIK

Active
ENAC LC10.082 Legutiano, ES
CEM DI-007 CEM DI-021 CEM DI-004 CEM DI-018 CEM DI-002 + 3 more
View Profile
ENAC LE178 Madrid, ES
UNE-EN 81-1 UNE-EN 81-2 UNE-EN 81-50 UNE-EN 81-20 UNE-EN 60947-4-1 + 3 more
View Profile
ENAC LE2485 Girona, ES
UNE-EN 25663 UNE-EN 872 UNE-EN ISO 6878 UNE EN 27888 UNE-EN ISO 10523 + 3 more
View Profile

URIKER

Active
ENAC LE775 Zamudio, ES
UNE 77061 SM 4500-NO-3 E UNE-EN ISO 7027-1 ISO 15923-1 UNE-EN ISO 7393-2 + 3 more
View Profile

No matching labs found.

Industries

High-speed rail manufacturers Railway infrastructure operators Braking system component suppliers Rolling stock maintenance facilities Rail safety regulatory bodies

Related Standards

  • EN 15152 Railway applications - Braking systems on rail vehicles - General requirements and definitions
  • EN 13571 Railway applications - Brakes - Disc brake pads - Specifications and approval
  • TSI HS RST (OJ 2008/217/EC) Technical Specification for Interoperability - High Speed Rolling Stock

Other Test Methods

0 labs selected