UIC 651

Railway Driver Cab Design and Layout

This standard specifies ergonomic and functional requirements for the layout and design of driver cabs in locomotives, railcars, and driving trailers to ensure operator safety, efficiency, and comfort during long operational shifts. It covers positioning of controls, displays, seats, visibility requirements, access, and environmental conditions within the cab environment. Compliance is essential for vehicle manufacturers, railway operators, and occupational health specialists to reduce driver fatigue, prevent errors, and meet modern safety and human factors standards. Accredited evaluation ensures systematic verification that cab designs meet ergonomic criteria and regulatory requirements for safe, sustainable railway operations.

What it measures

  • Control positioning and reach distances from driver seat
  • Visibility zones and sight lines to track ahead and sides
  • Display and instrument panel layout and readability
  • Driver seat dimensions, adjustment, and comfort properties
  • Access doorway dimensions, handholds, and ingress/egress safety
🇩🇪 DIN EN 12096 🇬🇧 BS EN 12096 🇫🇷 NF EN 12096 🇮🇹 UNI EN 12096 🇪🇸 UNE EN 12096 🇳🇱 NEN EN 12096 🇩🇪 DIN EN ISO 6682 🇬🇧 BS EN ISO 6682 🇫🇷 NF EN ISO 6682 🇮🇹 UNI EN ISO 6682 🇪🇸 UNE EN ISO 6682 🇳🇱 NEN EN ISO 6682
1,632 Accredited labs
19 Countries

Showing 101–125 of 875 labs

DIAL

Active
DAkkS D-PL-17358-02-00 Lüdenscheid, DE
DIN 5032-1 DIN 5032-2 DIN 5032-4 DIN 5033-8 DIN 5036-3 + 3 more
View Profile

DIANOVIS

Active
DAkkS D-ML-21243-01-01 Gera, DE
Kleines Blutbild (maschinell) Differentialblutbild (maschinell) Thrombozyten Retikulozyten Natriumchlorid + 3 more
View Profile
DAkkS D-K-15034-01-01 Gevelsberg, DE
Gleichspannung 10 mV Quellen > 100 mV > 1 V > 10 V > 100 V + 3 more
View Profile
DAkkS D-PL-11125-01-00 Nürnberg, DE
ASTM C 1166 IEC 60512-16-7 ID168 IEC 60512-16-9 AK gegen Sc1-70 + 3 more
View Profile
DAkkS D-ML-22411-01-00 Dresden, DE
Antikörper FILA-Klasse I Lymphozytäre Kreuzprobe E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1, KIR MICA, MICB, CCR5832 + 3 more
View Profile
DAkkS D-PL-11035-01-02 Essen, DE
ID136 > 140 DIN EN 143 DIN EN ISO 21149 DIN EN 13274-1 + 3 more
View Profile
DAkkS D-ML-21979-01-00 Hamburg, DE
HLA-Typsierung (HLA-B*27) Azoospermiefaktor (AZFa/AZFb/AZFc) Chorea Huntington (HTT) OMIM# 143100 + 3 more
View Profile
DAkkS D-K-11134-03-00 Kaiser-Wilhelm-Koog, DE
− Stromstärkeverhältnis - Gleichspannung / Messgeräte - Wechselspannung Gleichstromstärke > 100 µA + 3 more
View Profile
DAkkS D-ML-17345-01-01 Frankfurt, DE
Faktor-V-Mangel (F5 inklusive Thrombozyten, PAC-1 Bindung CASQ2, KCNJ2, CALM2, CALM3, TECRL ) dbSNP r6027 ) Kardiomyopathie (PKP2, DSG2, SCN5A ) + 3 more
View Profile
DAkkS D-ML-17345-01-00 Frankfurt, DE
aller Untersuchungsverfahren im flexible Webpräsenz des Medizinischen Laboratoriu (VWF:CB) vWF-Multimere Erythrozyten + 3 more
View Profile
DAkkS D-ML-13219-01-01 Dresden, DE
CD34+ Stammzellen Erythrozyten Hämoglobin Leukozyten Bakterien- und Hefezellen + 3 more
View Profile
DAkkS D-ML-13219-01-00 Dresden, DE
Akkreditierungsbereich. Die Liste ist Erythrozyten Leukozyten Hämatokrit Thrombozyten + 3 more
View Profile
DAkkS D-ML-13461-01-01 Bad Kreuznach, DE
AB0-System Isoagglutinine (Serumeigenschaften) Rh-Merkmal D Rh-Untergruppen + 3 more
View Profile
DAkkS D-ML-13327-01-00 Hagen, DE
AB0-Blutgruppen-Merkmale Isoagglutinine (Serumeigenschaften) Rhesusmerkmale K-Merkmale + 3 more
View Profile
DAkkS D-K-20506-01-01 Aachen, DE
am Standort DSA Daten- und Systemtechnik Schreibendes Bremsmessgerät (HU-Adapter) Beschleunigung + 1 more
View Profile
DAkkS D-K-15152-01-01 Aalen, DE
- Gleichspannung > 0,01 V - Gleichstromstärke 0,1 mV/V > 2 mV/V + 3 more
View Profile
DAkkS D-PL-18858-01-02 Krefeld, DE
DIN EN ISO 11357-2 DIN EN ISO 11357-3 DIN EN ISO 3071 DIN 54278-1 ISO 11890-2 + 3 more
View Profile
DAkkS D-PL-14555-02-01 Karlsruhe, DE
ASTM D 3227 DIN 3500 EN 14350-2 DIN EN 12350-9 DIN 53512 + 3 more
View Profile
DAkkS D-PL-12098-01-01 Karlsruhe, DE
(SPG42), SPAST (SPG4), SPG11, SPG7, VAMP DIN EN 30-1-1 DIN EN 30-1-2 DIN 13013 DIN 13014 + 3 more
View Profile
DAkkS D-K-23327-01-01 Bad Camberg, DE
Metrologic Group GmbH, nalen von: Wernau, D Neuss, D ≤ 1515 mm Wetzlar, D S.p.A., Turin, I + 3 more
View Profile
DAkkS D-PL-17009-06-00 Wiesbaden, DE
DIN EN 60950-1 EN IEC 62368-1 DIN EN 60204-1 DIN EN 60825-1 DIN EN 61010-1 + 3 more
View Profile
DAkkS D-PL-17009-02-00 Mainz, DE
DIN 31051 DIN EN 1005-1 DIN EN 1993-1-1 DIN EN 1993-1 DIN EN 1993-6 + 3 more
View Profile
DAkkS D-PL-17009-07-02 Köln, DE
IEC 60335-1: 2010 IEC 60335-2-29 DIN EN 60335-2-29 IEC 60335-2-65 DIN EN 60335-2-65 + 3 more
View Profile
DAkkS D-PL-17009-09-01 München, DE
DIN 4420-1 DIN 4420-3 DIN EN 61347-1 ISO 12117-2 DIN 53449 + 3 more
View Profile
DAkkS D-PL-17009-02-01 Mainz, DE
VDE 0113-201 VDE 0113-202 DIN EN 60204-1 EN 61508-1: VDE 0803-1 + 3 more
View Profile

No matching labs found.

Industries

Locomotive and railcar manufacturers Rolling stock modernization and refurbishment Railway operators and driver training Occupational health and ergonomics consulting Vehicle certification and type approval authorities

Related Standards

  • EN 12096 Railway applications — Passenger and freight rolling stock — Requirements for on-board safety
  • ISO 6682 Railway vehicles — Operator's cabs — Arrangement of controls and displays
  • EN 15898 Railway applications — Methods for evaluation of electromechanical switches — Guide to use

Other Test Methods

0 labs selected
Compare