ISO 3381:2013 / EN ISO 3381

Railway Interior Noise Measurement

ISO 3381 specifies standardized measurement procedures for determining sound pressure levels inside railbound passenger and freight vehicles under operating conditions. This test assesses passenger comfort, crew exposure, and compliance with occupational and environmental noise limits within train cabins and compartments. Manufacturers, operators, and occupational health consultants use these measurements to evaluate cabin acoustic quality, design noise control improvements, and ensure regulatory compliance. Accreditation guarantees consistent, defensible interior noise assessments that support both passenger safety and worker health protection.

What it measures

  • A-weighted sound pressure level inside vehicle (dB(A))
  • Noise levels at driver/operator positions
  • Frequency analysis of interior noise (1/3 octave bands)
  • Sound exposure level during typical operation
  • Noise at passenger seating areas
🇩🇪 DIN EN ISO 3095 🇬🇧 BS EN ISO 3095 🇫🇷 NF EN ISO 3095 🇮🇹 UNI EN ISO 3095 🇪🇸 UNE EN ISO 3095 🇳🇱 NEN EN ISO 3095 🇩🇪 DIN EN ISO 14837-1 🇬🇧 BS EN ISO 14837-1 🇫🇷 NF EN ISO 14837-1 🇮🇹 UNI EN ISO 14837-1 🇪🇸 UNE EN ISO 14837-1 🇳🇱 NEN EN ISO 14837-1
1,516 Accredited labs
17 Countries

Showing 326–350 of 799 labs

DAkkS D-ML-18493-01-00 Darmstadt, DE
HbA1c Großes Blutbild Kleines Blutbild Retikulocyten Natriumchlorid + 3 more
View Profile
DAkkS D-ML-13247-01-01 Sindelfingen, DE
Ristocetin Kofactor Aktivität Willibrand Faktors a-Hydroxy-Alprazolam Amilsulprid 7-amino-Flunitrazepam + 3 more
View Profile
DAkkS D-PL-18547-02-03 Neumünster, DE
DIN EN 16174 DIN CEN ISO/TS 16179 DIN EN 15933 DIN ISO 15178 DIN EN 15936 + 3 more
View Profile
DAkkS D-ML-18515-01-00 Dresden, DE
GPT GOT GGT Salmonellen Shigellen + 3 more
View Profile

Leadec BV &

Active
DAkkS D-K-21171-01-01 Chemnitz, DE
Gleichspannung 33 mV Messgeräte 0,33 V 330 V Gleichstromstärke 33 µA Messgeräte 0,33 mA + 3 more
View Profile
DAkkS D-K-21443-01-00 Schmalkalden, DE
(ein- und mehrgängige zylindrische Außen- und symmetrischem und unsymmetrischem Profil) Außengewinde + 3 more
View Profile
DAkkS D-PL-11240-01-01 Bremen, DE
DIN EN 60601-2-4 IEC 60512-4-1 DIN EN 124-2 IEC 60512-4-3 DIN EN 60601-2-44 + 3 more
View Profile
DAkkS D-ML-21457-02-00 Lehrte, DE
Aluminium Blei Eisen, Kupfer Ampicillin Cefepim + 3 more
View Profile
DAkkS D-K-21622-01-00 Unterschleißheim, DE
anteile Kohlenstoffmonoxid Kohlenstoffdioxid Methan Ethan + 3 more
View Profile
DAkkS D-K-15223-01-00 Wertheim, DE
Taupunkttemperatur Fixpunktzellen *) thermometer (SPRT) *) meter, direkt anzeigende thermometer und + 3 more
View Profile
DAkkS D-ML-14413-03-01 München, DE
Cryptococcus neoformans Cardiolipin AK Escherichia coli K1-AG Haemophilus influenzae Metromec Software AG + 3 more
View Profile
DAkkS D-ML-14413-01-01 München, DE
Gesamt IgG Albumin Treponema pallidum (Lues) Thrombozytäre Antikörper Treponema pallidum (Lues + 3 more
View Profile

MBS

Active
DAkkS D-PL-12159-01-00 Krefeld, DE
DIN EN ISO 16484-5 DIN EN ISO 16484-6 IEC 62386-101 IEC 62386-102 IEC 62386-103 + 3 more
View Profile
DAkkS D-PL-19548-01-03 Waldkraiburg, DE
DIN EN 13018 DIN EN 50289-1-2 DIN EN 50289-1-3 DIN EN 50289-1-4 DIN EN 50289-1-5 + 3 more
View Profile
DAkkS D-ML-13341-01-01 Berlin, DE
17-OH-Carbazepin Amiodaron, Desmethylamiodaron Amitriptylin Clobazam Clomipramin + 3 more
View Profile
DAkkS D-K-20515-01-00 Filderstadt, DE
Temperaturmessgrößen auch direktanzeigend 35 °C direktanzeigende > 200 °C auch direktanzeigend Temperaturmessgrößen −35 °C + 3 more
View Profile
DAkkS D-K-18366-01-01 Schweinfurt, DE
1350 mm Innen- und Tiefenmaße * > 300 mm Tiefenmessschieber * 0 mm Höhenmessschieber * 0 mm + 3 more
View Profile
DAkkS D-PL-13398-01-00 Berlin, DE
DIN ISO 16000-18 DIN 10113-3 ISO 11731 BS EN ISO 14644-1:2015 ISO 14644-3 + 1 more
View Profile

MLL MVZ

Active
DAkkS D-ML-13228-01-00 München, DE
Berliner-Blau-Reaktion Naphthylacetat-Esterase Pappenheim-Färbung Peroxidase-Reaktion Schnellfärbung (Diff-Quick) + 3 more
View Profile
DAkkS D-ML-13178-01-01 Mönchengladbach, DE
CRP Cystatin C HbA1c Großes Blutbild Kleines Blutbild + 3 more
View Profile
DAkkS D-PL-11241-01-01 Eberswalde, DE
DIN EN 50178: 1998 DIN EN ISO 2813 DIN EN ISO 4628-4 DIN EN ISO 10456 DIN EN ISO 12572 + 3 more
View Profile
DAkkS D-K-17552-01-01 Berlin, DE
Drehmoment * 0,2 N∙m > 10 N∙m bis Kalibriereinrichtungen > 100 N∙m Drehmomentschlüssel, 0,2 N∙m + 3 more
View Profile

MR COMP

Active
DAkkS D-PL-13383-01-00 Gelsenkirchen, DE
IEC 62570 DIN 13273-7
View Profile
DAkkS D-K-20595-01-00 Kirchheim unter Teck, DE
Tensile testing of metallic materials (I Vickers hardness test (ISO 6507) Taupunkttemperatur direktanzeigende > 200 °C Widerstandssensor > 300 °C + 3 more
View Profile
DAkkS D-ML-22373-01-00 Passau, DE
Großes Blutbild Kleines Blutbild Erythrozyten Hämoglobin Hämatokrit + 3 more
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturers Railway operators and fleet managers Occupational health and safety consultants Acoustic and noise control engineering Passenger transport and commuter rail

Related Standards

  • EN ISO 3095 Acoustics — Measurement of noise emitted by railbound vehicles
  • ISO 14837-1 Vibration from rail systems — Part 1: Fundamentals and measurement of vibration in free-field
  • EN 50160 Voltage characteristics of electricity supplied by public electricity networks

Other Test Methods

0 labs selected
Compare