ISO 3095:2013 / EN ISO 3095
Railway Pass-By Noise Measurement
ISO 3095 defines the standardized method for measuring and reporting noise emitted by railbound vehicles during pass-by at a fixed observer position. This is the primary standard used to assess compliance with European TSI Noise limits and national environmental regulations for passenger and freight trains. Manufacturers, railway operators, and regulatory authorities depend on this test to demonstrate noise performance, support fleet certification, and document compliance with noise reduction requirements. Accredited laboratories provide the independent, traceable measurements required for regulatory approval and public confidence in noise impact assessments.
What it measures
- Sound pressure level during pass-by (LAmax, dB(A))
- Noise emission per axle or per vehicle
- Frequency spectrum of pass-by noise
- Time-weighted sound exposure level
- Noise contribution by vehicle type and condition
🇩🇪
DIN EN ISO 3381
🇬🇧
BS EN ISO 3381
🇫🇷
NF EN ISO 3381
🇮🇹
UNI EN ISO 3381
🇪🇸
UNE EN ISO 3381
🇳🇱
NEN EN ISO 3381
🇩🇪
DIN EN ISO 14837-1
🇬🇧
BS EN ISO 14837-1
🇫🇷
NF EN ISO 14837-1
🇮🇹
UNI EN ISO 14837-1
🇪🇸
UNE EN ISO 14837-1
🇳🇱
NEN EN ISO 14837-1
1,273
Accredited labs
15
Countries
Showing 401–425 of 1,273 labs
DIN 51757
DIN EN ISO 12185
DIN EN ISO 3405
DIN EN 13016-1
DIN EN 237
+ 3 more
GMA-Werkstoffprüfung
Active
Koordinatenmesstechnik
Lasertracker*
0,5 m
1) In den CMC sind die erweiterten Messu
Bügelmessschrauben* 0 mm
+ 3 more
GMC-I Service
Active
- Gleichspannung
Messgeräte > 0,22 V
> 2,2 V
> 11 V
> 22 V
+ 3 more
GPR Gesundheits- und Pflegezentrum Rüsselsheim gemeinnützige GmbH Institut für Laboratoriumsmedizin
Active
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
Innen- und Tiefenmaße
Wägewert/
+ 3 more
GRAVICAL
Active
Innen- und Tiefenmaße
Konventioneller
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
+ 1 more
GTM Testing and Metrology
Active
Vickers hardness test (ISO 6507)
Kraft
Kraftaufnehmer und
Sound power — survey method (ISO 3746)
0,2 MN
+ 3 more
9,8 L ≤ V ≤ 10,2 L (25 L/h ≤ Q ≤ 500 L/h
98 L ≤ V ≤ 104 L (250 L/h ≤ Q ≤ 5000 L/h
970 L ≤ V ≤ 1005 L (2500 L/h ≤ Q ≤ 20000
1305 L ≤ V ≤ 1350 L (5000 L/h ≤ Q ≤ 8000
2660 L ≤ V ≤ 2700 L (5000 L/h ≤ Q ≤ 1000
DIN 30655-1
DIN 30655-2
DIN 3590-1
DIN 3590-2
DIN 30652-2
+ 3 more
Anti-Müller-Hormon
Androstendion
CA 125
Cortisol
DHEA-S
+ 3 more
Azoospermie (AZF-Mikrodeletionen)
Fragiles X-Syndrom (FMR1)
Chorea Huntington (HTT)
Spinocerebelläre Ataxie Typ1
(ATXN1); Typ 2 (ATXN2); Typ 3
+ 3 more
Gerico Lab Srl
Active
ETSI EN 319 412
ETSI EN 319 401
ETSI EN 319 411-2
ETSI EN 319 411-1
Gerinnungszentrum Rhein-Ruhr
Active
Thrombozytenaggregation
Epinephrin-Ristocetin) nach
Verschlusszeitbestimmung
Kollagen / ADP, PFA-Kollagen
Epinephrin, PFA-P2Y)
+ 3 more
Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen Leipzig mbH - MFPA Leipzig
Active
ISO 1920-4
DIN EN 480-11
DIN EN 12350-1
DIN EN 12350-3
DIN EN 12350-6
+ 3 more
Aktivator ADP / Epinephrin
Thrombozytenfunktionstest
Basophile Leukozyten, absolut
Basophile Leukozyten
Eosinophile Leukozyten
+ 3 more
Gigahertz Optik
Active
spektrale
Mikrofonempfindlichkeit
Photodioden
1 µA/W
Bestrahlungsstärke
+ 3 more
Glasgow City Council
Active
(HSG 248) – 2021
staining based on HSG 248
F2011 (BS 696:Part 2:1989)
F0131 (BS 1741:10-1:1989) using
F0008 (BS 696:Part 2:1989) using
+ 3 more
Gully Howard Technical
Active
HSG 227 (2004))
(HSG 264, 2012)
HSG 264 (2012) and Appx. 3 of
Appendix 5 of HSG 227 (2004))
ASTM D3835-16
ASTM D6204-19a
ASTM D6601-19
ISO 11443
ASTM D1238-13
+ 3 more
No matching labs found.