ISO 3095:2013 / EN ISO 3095
Railway Pass-By Noise Measurement
ISO 3095 defines the standardized method for measuring and reporting noise emitted by railbound vehicles during pass-by at a fixed observer position. This is the primary standard used to assess compliance with European TSI Noise limits and national environmental regulations for passenger and freight trains. Manufacturers, railway operators, and regulatory authorities depend on this test to demonstrate noise performance, support fleet certification, and document compliance with noise reduction requirements. Accredited laboratories provide the independent, traceable measurements required for regulatory approval and public confidence in noise impact assessments.
What it measures
- Sound pressure level during pass-by (LAmax, dB(A))
- Noise emission per axle or per vehicle
- Frequency spectrum of pass-by noise
- Time-weighted sound exposure level
- Noise contribution by vehicle type and condition
๐ฉ๐ช
DIN EN ISO 3381
๐ฌ๐ง
BS EN ISO 3381
๐ซ๐ท
NF EN ISO 3381
๐ฎ๐น
UNI EN ISO 3381
๐ช๐ธ
UNE EN ISO 3381
๐ณ๐ฑ
NEN EN ISO 3381
๐ฉ๐ช
DIN EN ISO 14837-1
๐ฌ๐ง
BS EN ISO 14837-1
๐ซ๐ท
NF EN ISO 14837-1
๐ฎ๐น
UNI EN ISO 14837-1
๐ช๐ธ
UNE EN ISO 14837-1
๐ณ๐ฑ
NEN EN ISO 14837-1
1,516
Accredited labs
17
Countries
Showing 1,226โ1,250 of 1,516 labs
Tetra Tech Consulting
Active
(HSG 248) โ 2021
RPSCA1 based on HSG 248
(PCM) based on HSG 248
RPSCA2 based on HSG 248
BS 7592:2008, BS 8554:2015
+ 2 more
TetraTec Instruments
Active
Railway brakes โ disc brake pads (UIC 54
Volumendurchfluss bzw.
0,01 m
Railway pantographs โ requirements for m
39 mL/h
+ 3 more
The Auditing Company
Active
#EN ISO 5164:14
# EN 116-97
# ISO 13736
NEN 4400-1
#ISO 6618
DC CURRENT
DC Resistance
Measurement
DC VOLTAGE
CAPACITANCE
+ 3 more
(HSG 248) โ 2021
03 based on HSG 248)
QOP01 based on HSG 248
(PCM) based on HSG 248
The Original Gauge Company
Active
LENGTH
Screw ring gauges (parallel)
LENGTH cont.
As for Involute Spline Gauges
See Note 2
+ 3 more
The Testing Lab
Active
DIN EN 933-11
BS EN ISO 17892-1:2014+A1:2022
BS EN ISO 17892-10:2018
BS EN ISO 17892-11:2019
BS EN ISO 17892-2:2014
+ 3 more
Thermo Electron LED
Active
- Gleichspannung
Messgerรคte 0,001 V bis
0,33 V bis
3,3 V bis
330 V bis
+ 3 more
Thomas Dudley
Active
BS 1212-2:1990 Clause 4
BS 1212-3:1990 Clause 4
DIN EN 997
Laktoseintoleranz (LCT -14055
BS 1212-4:1991 Clause 4, 13, 14
Masse oder
Konventioneller
Wรคgewert/
Massenormal *)
> 1 mg
+ 3 more
Railway brake โ magnetic track brakes (U
Kraft (WPM)
Lรคnge (WPM)
a) nur Vor-Ort-Kalibrierungen
Vickers hardness test (ISO 6507)
+ 3 more
Total Clean Air
Active
ISO 14644-3
BS EN ISO 14644-2:2015:Part 2
DIN EN 12469
BS EN ISO 14644-1:2015
BS EN ISO 14644-4:2022
+ 3 more
Trescal
Active
- Gleichspannung
/ Messgerรคte
10 V; 100 V; 1000 V
> 100 mV
> 0,22 V
+ 3 more
Tru-Cal Metrology
Active
including dial and digital
LENGTH (contโd)
Plain plug gauges (taper)
ANCILLARY MEASUREMENTS
Plain ring gauges (taper)
+ 3 more
Tyneside Standards
Active
Micrometers
See Notes 3 and 5
See Note 6
Caliper
length bars) โ See Note 5
+ 3 more
UNE-EN 60903
UNE-EN IEC 61243-1
UNE-EN 50508
UNE 204001
UNE-EN 61111
+ 2 more
TรV NORD CERT
Active
IEC 61000-4-39
IEC 61000-4-3: 2006
VDE 0847-4-3
IEC 61000-4-4: 2012
VDE 0847-4-4
+ 3 more
No matching labs found.