ISO 11820:2019

In-Situ Sound Attenuation Measurement of Silencers

ISO 11820 specifies the in-situ measurement method for determining the acoustic attenuation performance of silencers installed in railway ventilation ducts, brake systems, and exhaust lines. This test is critical for validating noise control equipment on operating trains and stationary installations where laboratory testing is impractical. Railway manufacturers, maintenance operators, and acoustic engineers use these measurements to verify compliance with noise regulations and to optimize silencer design. Accreditation ensures that attenuation claims are reliable and that performance targets for noise reduction are consistently achieved in real-world applications.

What it measures

  • Sound pressure level reduction across silencer (dB)
  • Attenuation performance by frequency band
  • Insertion loss of silencer in situ
  • Acoustic performance under operating conditions
  • Noise transmission loss through silencer element
🇩🇪 DIN EN ISO 11821 🇬🇧 BS EN ISO 11821 🇫🇷 NF EN ISO 11821 🇮🇹 UNI EN ISO 11821 🇪🇸 UNE EN ISO 11821 🇳🇱 NEN EN ISO 11821 🇩🇪 DIN EN ISO 3095 🇬🇧 BS EN ISO 3095 🇫🇷 NF EN ISO 3095 🇮🇹 UNI EN ISO 3095 🇪🇸 UNE EN ISO 3095 🇳🇱 NEN EN ISO 3095
1,516 Accredited labs
17 Countries

Showing 276–300 of 799 labs

DAkkS D-ML-13295-01-01 München, DE
Kleines Blutbild Differentialblutbild maschinell C-reaktives Protein (CRP) Differentialblutbild manuell Urinstatus + 3 more
View Profile
DAkkS D-ML-13295-03-00 München, DE
17-OH-Progesteron ACTH Androstendion Aldosteron Anti-TG Antikörper + 3 more
View Profile
DAkkS D-ML-13421-01-00 Ludwigshafen, DE
Liste aller Untersuchungsverfahren Webpräsenz des Medizinischen Laboratoriu CDT Ampicilin Cefepim + 3 more
View Profile
DAkkS D-ML-13400-01-00 Groß Grönau, DE
AMA M2-3E IgG Anti-CCP (Cyclische Citrullin Antikörper) IgG Anti-dsDNS-NCX IgG Anti- Transglutaminase + 3 more
View Profile
DAkkS D-K-15098-01-00 Leonberg, DE
Koordinatenmessgeräte geräte mit einem Messprojektoren einer Raumdiagonalen Messmikroskope ≤ 600 mm verwendete Abkürzungen:
View Profile
DAkkS D-K-15077-01-00 Aschaffenburg, DE
Parallelendmaße 0,5 mm bis DIN EN ISO 3650:1999 Parallelendmaße aus 0,5 mm bis Keramik oder Wolframkarbid nach + 3 more
View Profile
DAkkS D-K-22877-01-01 Eschweiler, DE
(ein- und mehrgängige zylindrische Außen- und geradlinigen Flanken und symmetrischem Profil sowie positiven Flankenwinkeln) + 3 more
View Profile
DAkkS D-ML-13173-01-00 Bad Oeynhausen, DE
Thrombozytenfunktion Amiodaron/Desethylamiodaron Cotinin Cyclosporin A Everolimus + 3 more
View Profile
DAkkS D-ML-21357-01-00 Heppenheim, DE
Albumin Alkohol ALP Anti-Faktor Xa (Fragmin) AT3 + 3 more
View Profile
DAkkS D-K-15082-01-00 Hamburg, DE
Durchfluss von Gasen 17 mL/s transferstandards Strömungswiderstand 5 mL/min 15,0 mL/min Laminar Flow Elemente 17 mL/min + 3 more
View Profile
DAkkS D-K-17059-02-01 Dresden, DE
Messschieber für Außen-, 0 mm Innen- und Tiefenmaße > 300 mm Tiefenmessschieber 0 mm Höhenmessschieber 0 mm + 3 more
View Profile
DAkkS D-ML-13087-01-00 Schüttorf, DE
10-Hydroxycarbazepin (MHD) Amiodaron, Desmethylamiodaron Clozapin, Norclozapin Cyclosporin A Amiodaron, Desethylamiodaron + 3 more
View Profile
DAkkS D-ML-13087-02-00 Leer, DE
HbA1c Basophile Eosinophile Erythrozyten Hämatokrit + 3 more
View Profile
DAkkS D-ML-17171-01-01 Baden-Baden, DE
HbA1c HCG qualitativ Erythrozyten Granulozyten basophil Granulozyten eosinophil + 3 more
View Profile
DAkkS D-ML-20249-01-00 Braunschweig, DE
HbA1c Retikulozyten Leukozyten Kleines Blutbild Großes Blutbild = + 3 more
View Profile
DAkkS D-ML-13183-01-00 Bremen, DE
HbA1c Zellzahl Blutbild groß Blutbild klein Retikulozyten + 3 more
View Profile
DAkkS D-ML-13107-01-00 Geesthacht, DE
Thrombozytenfunktionstest 2-Desoxypipradol (2-DPMP) 2-oxo-3-hydroxy-LSD 3.4-DMMC 3-Fluormethcathinon + 3 more
View Profile
DAkkS D-ML-13109-01-01 Hannover, DE
HbA1c Basophile Granulozyten Eosinophile Granulozyten Erythrozyten Hämatokrit + 3 more
View Profile
DAkkS D-ML-13319-02-01 Neuruppin, DE
Liste aller Untersuchungsverfahren Webpräsenz des Medizinischen Laboratoriu HbA1c Basophile Eosinophile + 3 more
View Profile
DAkkS D-ML-13132-01-00 Flintbek, DE
HbA1c Retikulozyten Leukozyten Neutrophile Granulozyten Lymphozyten + 3 more
View Profile
DAkkS D-ML-13194-01-01 Recklinghausen, DE
Blutsenkung Benzol Ethylbenzol Aceton, Isopropanol, Methanol Ethanol + 3 more
View Profile
DAkkS D-ML-13194-01-00 Recklinghausen, DE
Blutsenkung Benzol Ethanol Ethylbenzol Aceton, Isopropanol, Methanol + 3 more
View Profile
DAkkS D-K-18673-01-01 Dresden, DE
Gleichspannung 1 mV bis 10 mV Messgeräte > 10 mV bis 100 mV > 100 mV bis 220 mV > 220 mV bis 2,2 V > 2,2 V bis 11 V + 3 more
View Profile
DAkkS D-PL-14165-01-00 Oldenburg, DE
DIN EN 13040 DIN EN 12580 DIN EN 13039 DIN EN 13037 DIN EN 13038 + 3 more
View Profile

Labor 28 MVZ

Active
DAkkS D-ML-17085-01-00 Berlin, DE
Thrombozytenfunktionstest 5-Hydroxyindolessigsäure Amiodaron, Desethylamiodaron Tricyclische Antidepressiva Kohlenhydratdefizientes + 3 more
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturing Train maintenance and depot operations Acoustic engineering and noise control HVAC and ventilation system design Brake system suppliers and integrators

Related Standards

  • ISO 11821 Acoustics — In-situ measurement of sound insulation of windows and façades
  • EN ISO 3095 Acoustics — Measurement of noise emitted by railbound vehicles
  • ISO 7235 Acoustics — Laboratory measurement of sound absorption coefficient of materials in impedance tubes

Other Test Methods

0 labs selected
Compare