IEC 60494-2

Railway Pantograph Head Type 2 Dimensions

This standard specifies dimensional and material requirements for Type 2 pantograph head contacts designed for metropolitan and urban railway systems with different electrical and mechanical demands than main line networks. It defines standardized contact strip profiles to ensure compatibility with metro and tram catenary systems and interoperability across urban transit networks. Manufacturers and transit operators require accreditation of this test to ensure product compliance and safe, reliable operation in metropolitan electrified rail systems. Standardized Type 2 heads reduce compatibility issues and maintenance costs across metro and tram networks.

What it measures

  • Type 2 pantograph head contact width and profile geometry
  • Carbon or composite strip material composition and thickness
  • Contact surface hardness and wear resistance
  • Electrical conductivity and contact resistance
  • Mechanical deflection under typical operating forces
🇩🇪 DIN EN IEC 60494-1 🇬🇧 BS EN IEC 60494-1 🇫🇷 NF EN IEC 60494-1 🇮🇹 UNI EN IEC 60494-1 🇪🇸 UNE EN IEC 60494-1 🇳🇱 NEN EN IEC 60494-1 🇩🇪 DIN EN 50206-2 🇬🇧 BS EN 50206-2 🇫🇷 NF EN 50206-2 🇮🇹 UNI EN 50206-2 🇪🇸 UNE EN 50206-2 🇳🇱 NEN EN 50206-2
1,632 Accredited labs
19 Countries

Showing 501–525 of 875 labs

DAkkS D-PL-17693-02-01 Hannover, DE
DIN EN ISO 15061 (D 34) DIN EN 27888 (C 8) DIN EN 1484 (H 3) ISO 5667-21 DIN 38404-C 10 + 3 more
View Profile
DAkkS D-K-18539-01-00 Falkensee, DE
Tensile testing of metallic materials (I positiver Überdruck -0,01 bar Absolutdruck p abs Taupunkttemperatur + 3 more
View Profile
DAkkS D-K-15132-01-00 Oelde, DE
Akustik Übertragungsmaß von Messmikrofonen Messmikrofonen mit Dämpfung eines + 3 more
View Profile
DAkkS D-K-15218-01-00 Friedrichsdorf (Taunus), DE
Druck 0,03 bar Absolutdruck Pabs > -0,3 bar > 3,0 bar > −0,02 bar + 3 more
View Profile
DAkkS D-K-20502-01-01 Leipzig, DE
Positiver und negativer Positiver Überdruck p e −0,95 bar > 2,5 bar > 25 bar + 3 more
View Profile
DAkkS D-K-20427-01-00 Lörrach, DE
− Wärmezähler Durchflusssensoren als Teilgeräte von Wärme- und Kältezählern: + 3 more
View Profile
DAkkS D-PL-12032-01-02 Hüllhorst, DE
IEC 61000-4-2: 2008 VDE 0847-4-2 IEC 61000-4-3: 2006 VDE 0847-4-3 IEC 61000-4-4: 2012 + 3 more
View Profile
DAkkS D-K-15148-01-00 Oberndorf am Neckar, DE
Lehrdorne Railway maintenance — track geometry (EN > 100 mm Lehrringe 10 mm Rundheitsabweichung + 2 more
View Profile
DAkkS D-K-15021-01-01 Aschaffenburg, DE
Railway brake — magnetic track brakes (U − Ebenheit − Geradheit − Winkelnormale auch als Vor-Ort-Kalibrierung + 3 more
View Profile
DAkkS D-PL-11118-01-01 Rudolstadt, DE
DIN EN 1264-5 DIN EN 13647 DIN EN 71-10 DIN EN 50642 DIN EN ISO 14184-2 + 3 more
View Profile

PAConsult

Active
DAkkS D-PL-11130-01-02 Hamburg, DE
DIN 55440-1 DIN EN 22248 DIN EN 868-5 DIN EN 22876 DIN EN ISO 2234 + 3 more
View Profile
DAkkS D-PL-14361-01-01 Speyer, DE
DIN EN ISO 12185 ASTM D 4052 DIN EN ISO 3405 ASTM D 86 DIN EN 13016-1 + 3 more
View Profile
DAkkS D-PL-17186-01-01 Blomberg, DE
IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile
DAkkS D-PL-21530-01-01 Sand am Main, DE
DIN EN IEC 60068-2-38 DIN EN IEC 60068-2-11 BS ISO 9227:2022 DIN EN 60068-2-14 IEC 60068-2-60 + 3 more
View Profile

PLANCO-TEC

Active
DAkkS D-PL-22217-01-00 Neu-Eichenberg, DE
DIN EN 12457-4 DIN EN 12579 DIN EN 13040 DIN EN ISO 10523 (C 5) DIN EN 12880 (S 2a) + 3 more
View Profile
DAkkS D-K-17519-01-01 Niestetal, DE
Parallelendmaße aus 0,5 mm Einstellringe aus Stahl * nach DIN EN ISO 3650:1999 Keramik * DIN EN ISO 3650:1999 + 3 more
View Profile
DAkkS D-PL-11296-01-01 Kassel, DE
DIN EN 16019 DIN 50100 DIN EN 61373 IEC 61373 DIN EN 60310 + 3 more
View Profile
DAkkS D-K-21209-02-00 Berlin, DE
Railway brake — magnetic track brakes (U − Kraft (WPM) nur Vor-Ort-Kalibrierungen Kraft (WPM) 0,1 kN Vibration measuring instruments — test m + 3 more
View Profile
DAkkS D-PL-23019-01-01 Heidenau, DE
rs11887534 HABP2-Gen (c.1601G>A) rs7080536 IEC 61924-2 DIN EN ISO 1974 DIN 53121 + 3 more
View Profile
DAkkS D-K-15059-01-00 Freiburg im Breisgau, DE
Dosimetrie Luftkerma 5 mGy 2 mGy 100 µGy + 3 more
View Profile

Pachmann

Active
DAkkS D-ML-13345-01-00 Bayreuth, DE
EpCAM-positive Zellen (CD326) EpCAM-positive Tumorsphären EpCAM-positive Zellen human epidermal growth receptor 2 (Her-2/neu) + 2 more
View Profile
DAkkS D-ML-13116-01-01 Hameln, DE
Hämoglobin Selen Lithium Zink Eisen, Kupfer + 3 more
View Profile
DAkkS D-K-15089-01-01 Braunschweig, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 > 100 mm Sonderquerschnitt (rund Parallelendmaße * > 100 mm + 3 more
View Profile
DAkkS D-K-18321-01-00 Marburg, DE
Temperaturmessgrößen Widerstandsnormal thermometer (IPRT) Zeiss Industrielle Temperaturmessgrößen −35 °C + 3 more
View Profile
DAkkS D-K-12161-01-01 Blomberg, DE
Messschieber für 0 mm Außen-, Innen- und Tiefenmessschieber 0 mm Bügelmessschrauben 0 mm Messuhren + 3 more
View Profile

No matching labs found.

Industries

Metro and tram pantograph head manufacturers Urban transit rolling stock manufacturers Contact material and strip suppliers Metro system operators and maintainers

Related Standards

  • IEC 60494-1 Railway overhead lines — pantograph heads
  • EN 50206-2 Railway pantographs — requirements for metro and tram pantographs
  • EN 50119 Railway applications — fixed installations — electric traction overhead contact lines

Other Test Methods

0 labs selected
Compare