IEC 60494-2
Railway Pantograph Head Type 2 Dimensions
This standard specifies dimensional and material requirements for Type 2 pantograph head contacts designed for metropolitan and urban railway systems with different electrical and mechanical demands than main line networks. It defines standardized contact strip profiles to ensure compatibility with metro and tram catenary systems and interoperability across urban transit networks. Manufacturers and transit operators require accreditation of this test to ensure product compliance and safe, reliable operation in metropolitan electrified rail systems. Standardized Type 2 heads reduce compatibility issues and maintenance costs across metro and tram networks.
What it measures
- Type 2 pantograph head contact width and profile geometry
- Carbon or composite strip material composition and thickness
- Contact surface hardness and wear resistance
- Electrical conductivity and contact resistance
- Mechanical deflection under typical operating forces
🇩🇪
DIN EN IEC 60494-1
🇬🇧
BS EN IEC 60494-1
🇫🇷
NF EN IEC 60494-1
🇮🇹
UNI EN IEC 60494-1
🇪🇸
UNE EN IEC 60494-1
🇳🇱
NEN EN IEC 60494-1
🇩🇪
DIN EN 50206-2
🇬🇧
BS EN 50206-2
🇫🇷
NF EN 50206-2
🇮🇹
UNI EN 50206-2
🇪🇸
UNE EN 50206-2
🇳🇱
NEN EN 50206-2
1,632
Accredited labs
19
Countries
Showing 151–175 of 875 labs
EXcorLab
Active
DIN EN ISO 1135-4
EN ISO 1135-5
DIN EN ISO 10993-1
DIN EN ISO 8637-1
DIN EN ISO 7199
+ 2 more
Eckert & Ziegler Nuclitec
Active
Aktivität
20 Bq
> 20 Bq
Spezifische Aktivität
radioaktiver Lösungen 20 Bq·g
+ 3 more
Elektro Struß
Active
Gleichspannung 30 mV
/ Messgeräte
> 0,33 V
> 3,3 V
> 33 V
+ 3 more
Elektro Wilhelm
Active
Taupunkttemperatur
für Widerstands- ˃ 500 °C
- Direktanzeigende Thermometer
Thermoelemente ˃ 500 °C
Widerstands- -50 °C
+ 3 more
Element Metech KDK
Active
Elektrische Messgrößen
Gleichstrom- und Niederfrequenzmessgröße
Railway brake — magnetic track brakes (U
− Gleichspannung
− Gleichstromstärke
+ 3 more
Elster
Active
Durchfluss von Gasen 0,5 m³/h
Volumendurchfluss
> 4 m³/h
Railway overhead lines — pantograph head
> 10 m³/h
+ 3 more
DIN EN ISO 14607
DIN EN 13687-2
DIN EN ISO 15912
ASTM E290-22
DIN EN ISO 19023
+ 3 more
Railway brake — magnetic track brakes (U
Railway brakes — conditions for homologa
− Durchfluss von Flüssigkeiten
Railway brakes — estimation of braking f
− Masse strömender Flüssigkeiten
+ 3 more
Endress+Hauser SE+
Active
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
CDC73
(NM_000384: c.1-c.82)
ID152
EN ISO 11925-2
DIN EN 350
+ 3 more
Innen- und Tiefenmaße
Konventioneller
0,11 G
> 2 G
> 5 g
+ 3 more
Thrombozytenfunktion
Agomelatin
Amisulprid (Psychopharmaka)
Amitriptylin (TZA)
Aripiprazol (Neuroleptika)
+ 3 more
Thrombozytenfunktion
Agomelatin
Amisulprid (Psychopharmaka)
Amitriptylin (TZA)
Aripiprazol (Neuroleptika)
+ 3 more
DIN EN 13141-4
DIN EN 13141-6
DIN EN 13141-7
DIN EN 13141-8
DIN EN 13141-11
+ 3 more
Glykohämoglobin A1C (HbA1c)
Basophile Granulozyten
Eosinophile Granulozyten
Erythrozytenverteilungsbreite
(RDW)
+ 3 more
Blutzellen
Basophile Granulozyten
Basophile Granulozyten, Eosinophile Gran
Eosinophile Granulozyten, Erythrozyten,
Basophile Leukozyten, absolut
+ 3 more
Evonik Operations
Active
Taupunkttemperatur
Railway braking — urban guided transport
Widerstandssensor *)
Edelmetall- und
standssensor
+ 3 more
F.S. Fehrer Automotive
Active
DIN EN ISO 1798
DIN EN ISO 1856
Myopathie, Nemaline (TyP1, 3-10:
DIN EN ISO 14125
DIN EN ISO 179-1
+ 3 more
ISO 16750-3
DIN EN 60068-2-53
DIN EN 60068-2-64
ISO 20653
ISO 16750-4
+ 3 more
FGH Engineering & Test
Active
IEC 62271-1: 2017-07
IEC 62271-100: 2021
IEC 62271-108
IEC 62271-110
VDE 0115
+ 3 more
Frequenz
- Gleichspannung
Spannungsquellen 5 µV
1 mV
Messgeräte > 10 mV
+ 3 more
FILK Freiberg Institute g
Active
DIN ISO 48-4
ISO 21527-1
ISO 21527-2
DIN EN ISO 527-3
rs2066844
+ 3 more
No matching labs found.