IEC 60494-2

Railway Pantograph Head Type 2 Dimensions

This standard specifies dimensional and material requirements for Type 2 pantograph head contacts designed for metropolitan and urban railway systems with different electrical and mechanical demands than main line networks. It defines standardized contact strip profiles to ensure compatibility with metro and tram catenary systems and interoperability across urban transit networks. Manufacturers and transit operators require accreditation of this test to ensure product compliance and safe, reliable operation in metropolitan electrified rail systems. Standardized Type 2 heads reduce compatibility issues and maintenance costs across metro and tram networks.

What it measures

  • Type 2 pantograph head contact width and profile geometry
  • Carbon or composite strip material composition and thickness
  • Contact surface hardness and wear resistance
  • Electrical conductivity and contact resistance
  • Mechanical deflection under typical operating forces
🇩🇪 DIN EN IEC 60494-1 🇬🇧 BS EN IEC 60494-1 🇫🇷 NF EN IEC 60494-1 🇮🇹 UNI EN IEC 60494-1 🇪🇸 UNE EN IEC 60494-1 🇳🇱 NEN EN IEC 60494-1 🇩🇪 DIN EN 50206-2 🇬🇧 BS EN 50206-2 🇫🇷 NF EN 50206-2 🇮🇹 UNI EN 50206-2 🇪🇸 UNE EN 50206-2 🇳🇱 NEN EN 50206-2
1,399 Accredited labs
17 Countries

Showing 426–450 of 1,399 labs

UKAS 10287 Chelmsford, GB
(HSG 264, 2012)
View Profile
UKAS 0580 Bexhill, GB
FLOW Gas pressure (absolute) Gas pressure (gauge) DC CURRENT TEMPERATURE + 3 more
View Profile
DAkkS D-K-15109-01-01 Titisee-Neustadt, DE
Druck * Absolutdruck Pabs 1 bar; 3 bar Negativer und positiver Überdruck + 3 more
View Profile
UKAS 2083 Wellington, GB
(HSG 248) – 2021 M4 based on HSG 248 (PCM) based on HSG 248 M3 based on HSG 248 (HSG 264, 2012) + 1 more
View Profile

G&M Procter

Active
UKAS 2727 Perth, GB
based on ISO 11133:2014+Amd dependent) based on BS EN based on BS EN 12322:1999
View Profile
UKAS 4037 Welwyn Garden City, GB
(HSG 248) – 2021 (PCM) based on HSG 248 PRO02 based on HSG 248
View Profile
ENAC LC10.116 Puerto de Santa María, ES
3 mV  U < 330 mV 0,33 V  U < 3,3 V 3,3 0 mV  U < 200 mV 200 mV  U < 2 V 2 V  0 mV  U  100 mV 0,1 V < U  1 V 1 V < 5 mV  U  30 V 10 mV  U < 33 mV 50 Hz  f  1 kHz 1 kH + 3 more
View Profile
ENAC LE2121 Llinars del Valles, ES
ISO 9994 ISO 22702 ASTM F400 ASTM F2201
View Profile

GHMT

Active
DAkkS D-PL-17559-01-01 Bexbach, DE
DIN EN 50173-1 DIN EN 50173-2 DIN EN 50173-3 DIN EN 50173-4 DIN EN 50173-5 + 3 more
View Profile
RvA C480 Ljubljana, NL
IEC 17025
View Profile
DAkkS D-PL-11085-01-00 Frankfurt am Main, DE
DIN 51757 DIN EN ISO 12185 DIN EN ISO 3405 DIN EN 13016-1 DIN EN 237 + 3 more
View Profile
DAkkS D-K-11243-01-00 Stade, DE
Koordinatenmesstechnik Lasertracker* 0,5 m 1) In den CMC sind die erweiterten Messu Bügelmessschrauben* 0 mm + 3 more
View Profile

GMC-I Service

Active
DAkkS D-K-20313-01-01 Nürnberg, DE
- Gleichspannung Messgeräte > 0,22 V > 2,2 V > 11 V > 22 V + 3 more
View Profile

GOMETRICS

Active
ENAC LC10.194 Palau-solità i Plegamans, ES
EURAMET cg-18 CEM cg-19 UNE-EN ISO 14644-3 UNE-EN ISO 14644-1
View Profile
DAkkS D-ML-13406-01-00 Rüsselsheim, DE
Erythrozytenzahl Hämatokrit Leucozytendifferenzierung Leucozytenzahl MCV + 3 more
View Profile
DAkkS D-ML-18202-01-00 Rüsselsheim, DE
Erythrozytenzahl Hämatokrit Leucozytendifferenzierung Leucozytenzahl MCV + 3 more
View Profile
DAkkS D-K-18186-01-00 Bitterfeld-Wolfen, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) Innen- und Tiefenmaße Wägewert/ + 3 more
View Profile

GRAVICAL

Active
DAkkS D-K-21136-01-00 Damme, DE
Innen- und Tiefenmaße Konventioneller Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) + 1 more
View Profile
DAkkS D-K-15106-01-02 Bickenbach, DE
Vickers hardness test (ISO 6507) Kraft Kraftaufnehmer und Sound power — survey method (ISO 3746) 0,2 MN + 3 more
View Profile
ENAC LC10.219 Galapagar, ES
9,8 L ≤ V ≤ 10,2 L (25 L/h ≤ Q ≤ 500 L/h 98 L ≤ V ≤ 104 L (250 L/h ≤ Q ≤ 5000 L/h 970 L ≤ V ≤ 1005 L (2500 L/h ≤ Q ≤ 20000 1305 L ≤ V ≤ 1350 L (5000 L/h ≤ Q ≤ 8000 2660 L ≤ V ≤ 2700 L (5000 L/h ≤ Q ≤ 1000
View Profile
DAkkS D-PL-18598-01-02 Essen, DE
DIN 30655-1 DIN 30655-2 DIN 3590-1 DIN 3590-2 DIN 30652-2 + 3 more
View Profile
DAkkS D-ML-17457-01-00 Minden, DE
Anti-Müller-Hormon Androstendion CA 125 Cortisol DHEA-S + 3 more
View Profile
DAkkS D-ML-22602-01-01 Berlin, DE
Azoospermie (AZF-Mikrodeletionen) Fragiles X-Syndrom (FMR1) Chorea Huntington (HTT) Spinocerebelläre Ataxie Typ1 (ATXN1); Typ 2 (ATXN2); Typ 3 + 3 more
View Profile
ACCREDIA 02192 Torino, IT
ETSI EN 319 412 ETSI EN 319 401 ETSI EN 319 411-2 ETSI EN 319 411-1
View Profile
DAkkS D-ML-18276-01-01 Duisburg, DE
Thrombozytenaggregation Epinephrin-Ristocetin) nach Verschlusszeitbestimmung Kollagen / ADP, PFA-Kollagen Epinephrin, PFA-P2Y) + 3 more
View Profile

No matching labs found.

Industries

Metro and tram pantograph head manufacturers Urban transit rolling stock manufacturers Contact material and strip suppliers Metro system operators and maintainers

Related Standards

  • IEC 60494-1 Railway overhead lines — pantograph heads
  • EN 50206-2 Railway pantographs — requirements for metro and tram pantographs
  • EN 50119 Railway applications — fixed installations — electric traction overhead contact lines

Other Test Methods