IEC 60494-2
Railway Pantograph Head Type 2 Dimensions
This standard specifies dimensional and material requirements for Type 2 pantograph head contacts designed for metropolitan and urban railway systems with different electrical and mechanical demands than main line networks. It defines standardized contact strip profiles to ensure compatibility with metro and tram catenary systems and interoperability across urban transit networks. Manufacturers and transit operators require accreditation of this test to ensure product compliance and safe, reliable operation in metropolitan electrified rail systems. Standardized Type 2 heads reduce compatibility issues and maintenance costs across metro and tram networks.
What it measures
- Type 2 pantograph head contact width and profile geometry
- Carbon or composite strip material composition and thickness
- Contact surface hardness and wear resistance
- Electrical conductivity and contact resistance
- Mechanical deflection under typical operating forces
🇩🇪
DIN EN IEC 60494-1
🇬🇧
BS EN IEC 60494-1
🇫🇷
NF EN IEC 60494-1
🇮🇹
UNI EN IEC 60494-1
🇪🇸
UNE EN IEC 60494-1
🇳🇱
NEN EN IEC 60494-1
🇩🇪
DIN EN 50206-2
🇬🇧
BS EN 50206-2
🇫🇷
NF EN 50206-2
🇮🇹
UNI EN 50206-2
🇪🇸
UNE EN 50206-2
🇳🇱
NEN EN 50206-2
1,632
Accredited labs
19
Countries
Showing 1,101–1,125 of 1,632 labs
Pennington Choices
Active
(HSG 264, 2012)
and Appx. 3 of HSG 227 (2004))
Executive guides HSG 264 (2012)
Perry Analytical
Active
(HSG 248) – 2021
(PCM) based on HSG 248
Manual based on HSG 248
Perschmann Calibration
Active
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
> 100 mm
Sonderquerschnitt (rund
Parallelendmaße * > 100 mm
+ 3 more
Temperaturmessgrößen
Widerstandsnormal
thermometer (IPRT)
Zeiss Industrielle
Temperaturmessgrößen −35 °C
+ 3 more
Phoenix Contact
Active
Messschieber für 0 mm
Außen-, Innen- und
Tiefenmessschieber 0 mm
Bügelmessschrauben 0 mm
Messuhren
+ 3 more
Polytest Ingenieure
Active
DIN EN ISO 9934-1
DIN ISO 815-1
DIN ISO 815-2
DIN ISO 4593
DIN EN 50178: 1998
+ 3 more
Poulten Selfe and Lee
Active
TEMPERATURE
Viscosity constant ‘C’
Reference viscometers:
ASTM D4052 (Digital density
Power Diagnostix Systems
Active
Impulsladung
Anstiegszeit
Impulsdauer
Wechselspannung 1 V
> 1,1 kV
+ 3 more
Differentialblutbild
Erythrozyten
Hämatokrit
Leukozyten
Retikulozyten
+ 3 more
External (Tip) Diameter
Helix (lead) total deviation (F
GEARS SPUR/HELICAL EXTERNAL (cont’d)
As for Involute Spline Gauges
HbA1c
Automatisches Blutbild
Leukozyten
Normoblasten
Retikulozyten
+ 3 more
Calcium
Bilirubin gesamt
Creatinkinase-Muscle-Brain
TPZ nach Quick
Immunglobulin A
+ 3 more
Vickers hardness test (ISO 6507)
Frost- / Taupunkt- –90 °C
Taupunkttemperatur
Taupunktspiegel, –80 °C
–60 °C
+ 3 more
ProfEC Ventus
Active
IEC 61400-12 Ed.1 *
IEC 61400-12-1 Ed.3 *
IEC 61400-12-3 Ed.1 *
IEC 61400-12-4 Ed.1 *
IEC 61400-12-5 Ed.1 *
+ 3 more
ISO 15835-2
UNE-EN 10002-1
BS EN ISO 15630-1:2019
UNE-EN 10080
BS EN ISO 15630-3:2019
+ 3 more
ISO 6579-1
ISO 15213-2
ISO 11290-1
ISO 7932
F100 based on BS EN ISO
+ 3 more
Pullman Instruments (UK)
Active
DC CURRENT
Measurement
DC VOLTAGE
AC Current Generation
DC RESISTANCE (cont’d)
+ 3 more
QIMA Testing (Germany)
Active
DIN EN 16711-2
DIN EN 16711-1
IEC 62321-2
DIN EN 12472
DIN CEN ISO/TS 16179
+ 3 more
QMK
Active
Gleichspannung 10 mV
Quellen > 120 mV
Vorverstärker > 1,2 V
> 12 V
> 120 V
+ 3 more
QS-Grimm
Active
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Zylindrische Normale 1 mm
Innenzylinder *
> 100 mm
+ 3 more
QUALILAB
Active
EN 12966: 2014 Section 4.5.4
DIN EN 55025: 2018
DIN EN 60068-2-30
(CISPR 25:2002) Section 6
ISO 11452-4: 2020
+ 3 more
ISO 13320
VDE 414-9-11
NF V08-250
ISO 19343
DIN EN ISO 7899-1
+ 3 more
No matching labs found.