EN 14253

Railway Track Geometry Calculation and Classification

EN 14253 establishes methods for measuring, calculating, and classifying geometric parameters of railway tracks including gauge, alignment, and longitudinal profile. This standard provides quality classifications that determine allowable operating speeds and maintenance priorities for railway lines across Europe. Railway infrastructure operators, maintenance contractors, and network authorities rely on accredited measurement and assessment to ensure safe train operations and optimize maintenance scheduling. Accreditation of testing laboratories guarantees consistent, reproducible measurement methodologies and impartial classification decisions. Proper track geometry monitoring prevents derailments, reduces component wear, and maintains passenger and freight service reliability.

What it measures

  • Track gauge (rail-to-rail distance)
  • Horizontal and vertical alignment deviations
  • Longitudinal profile and gradient parameters
  • Twist and cross-level of the track
  • Quality classification relative to speed limits
🇩🇪 DIN EN 14253:2019 🇬🇧 BS EN 14253:2019 🇫🇷 NF EN 14253:2019 🇮🇹 UNI EN 14253:2019 🇪🇸 UNE EN 14253:2019 🇳🇱 NEN EN 14253:2019 🇩🇪 DIN EN 13848-1 🇬🇧 BS EN 13848-1 🇫🇷 NF EN 13848-1 🇮🇹 UNI EN 13848-1 🇪🇸 UNE EN 13848-1 🇳🇱 NEN EN 13848-1
1,399 Accredited labs
17 Countries

Showing 101–125 of 133 labs

ENAC LC10.163 Badalona, ES
Rangos de caudal (m3/h): 1 m3/h ≤ Q < 25
View Profile
ENAC LC10.236 San Ginés, ES
1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 5 5 kg 10 kg 20 kg 100 kg 200 kg 500 kg 1000 kg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 5 + 2 more
View Profile
ENAC LC10.077 Madrid, ES
2 · 10–6 mol/mol  C  100 · 10–6 mol/mo 0,1 · 10–2 mol/mol < C  2,5 · 10–2 mol/ 1 · 10–6 mol/mol  C  100 · 10–6 mol/mo 5 · 10–6 mol/mol  C  20 · 10–6 mol/mol 0,15 · 10–2 mol/mol  C  20 · 10–2 mol/ + 3 more
View Profile

OCA GLOBAL

Active
ENAC LE2316 Pozuelo de Alarcón, ES
UNE-EN 14385 UNE-EN 15259 UNE-EN 13211 BS ISO 9096:2017 UNE 77216 + 3 more
View Profile
ENAC LE2504 Las Rozas de Madrid, ES
UNE-EN 14363 UNE-EN 50367 UNE-EN 50317 UNE-EN 12663-1
View Profile
ENAC LE2092 Alcázar de San Juan, ES
UNE-EN ISO/IEC 17025
View Profile
ENAC LE2055 Nigrán, ES
UNE-EN 1789
View Profile
ENAC LC10.264 Sant Martí Sarroca, ES
(2,2 ± 0,1) ⋅ 10-2 mol/mol (99,5 ± 0,5) (15 ± 5) ⋅ 10-6 mol/mol (100 ± 5) ⋅ 10-6 (7,5 ± 0,2) ⋅ 10-2 mol/mol (15 ± 0,5) ⋅
View Profile
ENAC LC10.120 Tres Cantos, ES
5 mV ≤ U ≤ 10 V 10 V < U ≤ 1000 V 45 Hz ≤ f ≤ 60 Hz 10 mV ≤ U ≤ 10 V 10 V 100 µA ≤ I ≤ 400 mA 400 mA < I ≤ 10 A 10 300 mA ≤ I ≤ 15 A 45 Hz ≤ f ≤ 60 Hz 100 µA ≤ I ≤ 400 mA 40 + 2 more
View Profile
ENAC LC10.178 Madrid, ES
CEM Ed
View Profile
ENAC LC10.069 Sant Celoni, ES
0,03 · 10-2 mol/mol  C < 0,3 · 10-2 mol 0,3 · 10-2 mol/mol  C  1,1 · 10-2 mol/ 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 9 · 10-6 mol/mol  C < 75 · 10-6 mol/mol + 3 more
View Profile
ENAC LC10.221 Terrassa, ES
(15 ± 1) ⋅ 10-6 mol/mol (1000 ± 50) ⋅ 10 (8 ± 0,5) ⋅ 10-2 mol/mol (1,4 ± 0,1) ⋅ 1 (3000 ± 150) ⋅ 10-6 mol/mol (9 ± 1) ⋅ 10 (80 ± 8) ⋅ 10-6 mol/mol (100 ± 8) ⋅ 10-6 mol/mol
View Profile

SEQUOPRO

Active
ENAC LC10.166 Tres Cantos, ES
0,015 l/min ≤ Q ≤ 40 l/min 0,0 · 10-9 mol/mol 20 ⋅ 10-9 mol/mol ≤ C ≤ 500 ⋅ 10-9 mol/m 0,00 · 10-6 mol/mol 0,5 ⋅10-6 mol/mol ≤ C ≤ 10 ⋅10-6 mol/mol + 3 more
View Profile
ENAC LC10.216 Palmas de Gran Canaria, ES
1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 .1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg
View Profile

SAICA

Active
ENAC LC10.191 Puerto de Santa María, ES
CEM DI-021 CEM DI-004 CEM EL-007 CEM DI-003 CEM DI-008 + 3 more
View Profile

SIMETRYCAL

Active
ENAC LC10.192 Sevilla, ES
EURAMET CG-6 CEM DI-021 CEM DI-004 CEM DI-013 CEM DI-012 + 3 more
View Profile
ENAC LE249 Bueu, ES
UNE-EN ISO 8754 ASTM D1298 UNE-EN ISO 12185 ASTM D1319 ASTM D 5291 + 3 more
View Profile
ENAC LE011 Madrid, ES
DIN EN 61010-2-010: 2015 DIN EN 60335-2-9 IEC 61000-4-8: 2009 IEC 61010-2-010: 2014 DIN EN 61010-2-101 + 3 more
View Profile
ENAC LC10.203 Zaragoza, ES
-95 kPa ≤ P < 0 kPa 0 kPa ≤ P ≤ 1 kPa 1 -95 kPa ≤ P ≤ -5 kPa - 5 kPa < P < -1 kP
View Profile
ENAC LC10.210 Cornellà de Llobregat, ES
(5 ± 0,2) · 10-2 mol/mol (1000 ± 50) · 10-6 mol/mol (15 ± 2) · 10-6 mol/mol
View Profile
ENAC LE2749 Zaragoza, ES
UNE-EN 12341 0,015 l/min ≤ Q ≤ 50 l/min 20 ⋅ 10-9 mol/mol ≤ C ≤ 500 ⋅ 10-9 mol/m 20 ⋅10-9 mol/mol ≤ C ≤ 100 ⋅ 10-9 mol/mo 100 ⋅ 10-9 mol/mol ≤ C ≤ 1000 ⋅ 10-9 mol + 3 more
View Profile

TECYGES

Active
ENAC LC10.232 Zaragoza, ES
CEM Procedimiento
View Profile
ENAC LE2333 Castellgalí, ES
DIN EN 16615 DIN EN 17658 DIN EN 13697 IEC 60127-6 DIN EN 13727 + 3 more
View Profile
ENAC LC10.078 Illescas, ES
UNE-EN ISO 868 ASTM D 2240 ISO 48-9 UNE 7050-3 UNE-EN ISO 10360-2 + 3 more
View Profile

TESICNOR

Active
ENAC LE2354 Noáin, ES
UNE-EN 60903 UNE-EN IEC 61243-1 UNE-EN 50508 UNE 204001 UNE-EN 61111 + 2 more
View Profile

No matching labs found.

Industries

Railway infrastructure maintenance and operations High-speed and conventional rail networks Railway engineering and design consultancy Track inspection and diagnostics services Urban transit and light rail systems

Related Standards

  • EN 14253:2019 Railway applications - Track geometry - Measuring the position of railway track - Specification and tolerances for track geometry quality
  • EN 13848-1 Railway applications - Track - Track geometry quality - Part 1: Characterisation of track geometry
  • EN 13848-5 Railway applications - Track - Track geometry quality - Part 5: Geometric quality assessment of a track section for maintenance

Other Test Methods

0 labs selected
Compare