ISO 5348

Accelerometer Mechanical Mounting Methods

ISO 5348 specifies the mechanical mounting requirements and installation methods for accelerometers used in vibration measurement and monitoring applications. Proper mounting is critical because accelerometer resonance and damping characteristics are strongly influenced by how the device is attached to the test structure. Industries including aerospace, automotive, mechanical engineering, and maintenance rely on this standard to ensure measurement accuracy and repeatability in vibration diagnostics. Accreditation to this standard demonstrates that a laboratory understands the physical factors affecting transducer performance and can provide traceable, reliable vibration data. Correct mounting practices are fundamental to valid vibration measurement across all frequency ranges.

What it measures

  • Transverse sensitivity effects of mounting
  • Frequency response accuracy with different mounting methods
  • Resonance frequency stability
  • Mechanical coupling effects
  • Temperature compensation for mounted accelerometers
🇩🇪 DIN EN ISO 16063-41 🇬🇧 BS EN ISO 16063-41 🇫🇷 NF EN ISO 16063-41 🇮🇹 UNI EN ISO 16063-41 🇪🇸 UNE EN ISO 16063-41 🇳🇱 NEN EN ISO 16063-41 🇩🇪 DIN EN ISO 6954 🇬🇧 BS EN ISO 6954 🇫🇷 NF EN ISO 6954 🇮🇹 UNI EN ISO 6954 🇪🇸 UNE EN ISO 6954 🇳🇱 NEN EN ISO 6954
1,817 Accredited labs
19 Countries

Showing 926–950 of 961 labs

DAkkS D-PL-19426-01-00 Dresden, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3 DIN EN 61400-11
View Profile
DAkkS D-PL-12047-01-01 Saarbrücken, DE
ISO 7637-1 ISO 7637-2 ISO 7637-3: 2016 ISO 10605 ISO 11452-2: 2019 + 3 more
View Profile
DAkkS D-PL-17359-01-00 Münster, DE
DIN EN 1317-1* DIN EN 1317-2* DIN EN 1317-3* DIN V ENV 1317-4* DIN CEN/TS 1317-7* + 3 more
View Profile
DAkkS D-PL-20957-01-00 Nürnberg, DE
IEC 61000-6-1 IEC 61000-6-2: 2005 DIN EN 50155 VDE 0115-200 DIN EN 50121-3-2 + 3 more
View Profile

enveon

Active
DAkkS D-PL-21616-01-01 München, DE
VDE 0468-2-1 IEC 60068-2-1 VDE 0468-2-2 IEC 60068-2-2 DIN EN 60068-2-14 + 3 more
View Profile
DAkkS D-K-15019-01-01 Landkreis Fürstenfeldbruck, DE
Hochspannung - Wechselspannung Bereiche Rechteckspannung Amplitudenparameter + 3 more
View Profile

eumetron

Active
DAkkS D-K-15151-01-01 Aalen, DE
− Durchmesser − Parallelendmaße − Formabweichung − Strichmaße, Abstände − Virtuelle Koordinatenmessgeräte + 3 more
View Profile
DAkkS D-PL-14078-01-03 Wesseling, DE
DIN 19698-1 DIN 19698-2 DIN ISO 11464 DIN EN ISO 54321 DIN EN 12457-4 + 3 more
View Profile

europascal

Active
DAkkS D-K-15055-01-01 Hanau, DE
- Gleichspannung / Messgeräte > 0 V > 0,22 V > 2,2 V + 3 more
View Profile
DAkkS D-K-21048-01-00 Kirchzarten, DE
Positiver und negativer Positiver Überdruck p e 1) In den CMC sind die erweiterten Messu
View Profile
DAkkS D-PL-19499-01-00 Kaufering, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3
View Profile

iKM Service

Active
DAkkS D-K-21115-01-00 Zwickau, DE
Industrielle Messtechnik ≤ 860 mm GmbH, Oberkochen, D
View Profile

iLF Magdeburg

Active
DAkkS D-PL-18869-01-01 Magdeburg, DE
DIN EN ISO 9117-3 DIN EN ISO 9117-5 DIN EN ISO 1463 DIN EN ISO 2808 DIN EN ISO 2178 + 3 more
View Profile
DAkkS D-K-17060-01-00 Tettnang, DE
Taupunkttemperatur –0,91 bar bis Positiver und negativer Überdruck p *) (ein- oder mehrgängige + 3 more
View Profile

ift Rosenheim

Active
DAkkS D-PL-11349-01-01 Rosenheim, DE
ASTM E 330/E 330M ASTM E 283/E283M DIN 4103-1 DIN 68706-1 UNE-EN 12211 + 3 more
View Profile
DAkkS D-PL-21129-01-03 Gießen, DE
DIN EN ISO 5667-1 (A 4) DIN ISO 5667-5 (A 14) DIN EN ISO 5667-3 (A 21) DIN EN ISO 19458 (K 19) DIN 19643-1 + 3 more
View Profile

imat-uve

Active
DAkkS D-PL-14052-01-01 Mönchengladbach, DE
ISO 3795 DIN 75200 VDA 675-130 DIN 53438-1 DIN 53438-2 + 3 more
View Profile
DAkkS D-PL-20493-01-00 Herrsching, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3
View Profile
DAkkS D-K-15219-01-02 Helmstadt, DE
Taupunkttemperatur fixpunktzellen Railway braking — urban guided transport Railway vehicle body structural requirem SPRT-Sensor + 3 more
View Profile
DAkkS D-K-19194-01-00 Idstein, DE
Absolutdruck p abs > 0,8 bar > 1,2 bar > 20 bar + 3 more
View Profile

iocto

Active
DAkkS D-K-21204-01-00 Hofheim am Taunus, DE
Taupunkttemperatur direktanzeigende −45 °C Railway vehicle body structural requirem Widerstandssensor direktanzeigende > 200 °C + 3 more
View Profile
DAkkS D-PL-23162-01-01 München, DE
VDE 0468-2-1 DIN EN IEC 60068-2-38 IEC 60068-2-2 DIN EN-60068-2-1 IEC 60068-2-30 + 3 more
View Profile
DAkkS D-ML-13309-01-00 Dresden, DE
Basophile Eosinophile Erythrozyten Hämatokrit Leukozyten + 3 more
View Profile
DAkkS D-ML-19652-01-00 Frankfurt, DE
Großes Blutbild TSH Immunglobulin E 25-OH-Vitamin D Vitamin B12 + 3 more
View Profile
DAkkS D-K-22604-01-01 Neumünster, DE
Kraft (WPM) Vibration measuring instruments — test m Werkstoffprüfmaschinen Acoustics — tonality assessment (DIN 456 Measurement of traffic noise immissions + 3 more
View Profile

No matching labs found.

Industries

Aerospace and aircraft maintenance Automotive and engine testing Machinery condition monitoring Mechanical engineering and R&D Vibration diagnostics and predictive maintenance

Related Standards

  • ISO 16063-41 Methods for the calibration of vibration and shock transducers – Calibration of accelerometers
  • ISO 6954 Mechanical vibration – Criteria for the evaluation of vibration on machines with nominal powers above 15 kW and nominal speeds between 120 and 15000 r/min
  • ISO 10816-1 Mechanical vibration – Evaluation of machine vibration by measurements on non-rotating parts

Other Test Methods

0 labs selected
Compare