ISO 5348

Accelerometer Mechanical Mounting Methods

ISO 5348 specifies the mechanical mounting requirements and installation methods for accelerometers used in vibration measurement and monitoring applications. Proper mounting is critical because accelerometer resonance and damping characteristics are strongly influenced by how the device is attached to the test structure. Industries including aerospace, automotive, mechanical engineering, and maintenance rely on this standard to ensure measurement accuracy and repeatability in vibration diagnostics. Accreditation to this standard demonstrates that a laboratory understands the physical factors affecting transducer performance and can provide traceable, reliable vibration data. Correct mounting practices are fundamental to valid vibration measurement across all frequency ranges.

What it measures

  • Transverse sensitivity effects of mounting
  • Frequency response accuracy with different mounting methods
  • Resonance frequency stability
  • Mechanical coupling effects
  • Temperature compensation for mounted accelerometers
🇩🇪 DIN EN ISO 16063-41 🇬🇧 BS EN ISO 16063-41 🇫🇷 NF EN ISO 16063-41 🇮🇹 UNI EN ISO 16063-41 🇪🇸 UNE EN ISO 16063-41 🇳🇱 NEN EN ISO 16063-41 🇩🇪 DIN EN ISO 6954 🇬🇧 BS EN ISO 6954 🇫🇷 NF EN ISO 6954 🇮🇹 UNI EN ISO 6954 🇪🇸 UNE EN ISO 6954 🇳🇱 NEN EN ISO 6954
1,591 Accredited labs
17 Countries

Showing 126–148 of 148 labs

ENAC LC10.069 Sant Celoni, ES
0,03 · 10-2 mol/mol  C < 0,3 · 10-2 mol 0,3 · 10-2 mol/mol  C  1,1 · 10-2 mol/ 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 9 · 10-6 mol/mol  C < 75 · 10-6 mol/mol + 3 more
View Profile
ENAC LC10.221 Terrassa, ES
(15 ± 1) ⋅ 10-6 mol/mol (1000 ± 50) ⋅ 10 (8 ± 0,5) ⋅ 10-2 mol/mol (1,4 ± 0,1) ⋅ 1 (3000 ± 150) ⋅ 10-6 mol/mol (9 ± 1) ⋅ 10 (80 ± 8) ⋅ 10-6 mol/mol (100 ± 8) ⋅ 10-6 mol/mol
View Profile

SEQUOPRO

Active
ENAC LC10.166 Tres Cantos, ES
0,015 l/min ≤ Q ≤ 40 l/min 0,0 · 10-9 mol/mol 20 ⋅ 10-9 mol/mol ≤ C ≤ 500 ⋅ 10-9 mol/m 0,00 · 10-6 mol/mol 0,5 ⋅10-6 mol/mol ≤ C ≤ 10 ⋅10-6 mol/mol + 3 more
View Profile
ENAC LC10.216 Palmas de Gran Canaria, ES
1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 .1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg
View Profile

SAICA

Active
ENAC LC10.191 Puerto de Santa María, ES
CEM DI-021 CEM DI-004 CEM EL-007 CEM DI-003 CEM DI-008 + 3 more
View Profile

SIMETRYCAL

Active
ENAC LC10.192 Sevilla, ES
EURAMET CG-6 CEM DI-021 CEM DI-004 CEM DI-013 CEM DI-012 + 3 more
View Profile
ENAC LE011 Madrid, ES
DIN EN 61010-2-010: 2015 DIN EN 60335-2-9 IEC 61000-4-8: 2009 IEC 61010-2-010: 2014 DIN EN 61010-2-101 + 3 more
View Profile
ENAC LC10.203 Zaragoza, ES
-95 kPa ≤ P < 0 kPa 0 kPa ≤ P ≤ 1 kPa 1 -95 kPa ≤ P ≤ -5 kPa - 5 kPa < P < -1 kP
View Profile
ENAC LC10.210 Cornellà de Llobregat, ES
(5 ± 0,2) · 10-2 mol/mol (1000 ± 50) · 10-6 mol/mol (15 ± 2) · 10-6 mol/mol
View Profile
ENAC LE2749 Zaragoza, ES
UNE-EN 12341 0,015 l/min ≤ Q ≤ 50 l/min 20 ⋅ 10-9 mol/mol ≤ C ≤ 500 ⋅ 10-9 mol/m 20 ⋅10-9 mol/mol ≤ C ≤ 100 ⋅ 10-9 mol/mo 100 ⋅ 10-9 mol/mol ≤ C ≤ 1000 ⋅ 10-9 mol + 3 more
View Profile

TECYGES

Active
ENAC LC10.232 Zaragoza, ES
CEM Procedimiento
View Profile
ENAC LE2333 Castellgalí, ES
DIN EN 16615 DIN EN 17658 DIN EN 13697 IEC 60127-6 DIN EN 13727 + 3 more
View Profile
ENAC LC10.078 Illescas, ES
UNE-EN ISO 868 ASTM D 2240 ISO 48-9 UNE 7050-3 UNE-EN ISO 10360-2 + 3 more
View Profile

TESICNOR

Active
ENAC LE2354 Noáin, ES
UNE-EN 60903 UNE-EN IEC 61243-1 UNE-EN 50508 UNE 204001 UNE-EN 61111 + 2 more
View Profile
ENAC LE1121 Tres Cantos, ES
UNE-EN 14181 UNE-EN 13284-2 UNE-EN 15259 UNE-EN 16911-2 UNE-EN 14385 + 3 more
View Profile

UNIMETRIK

Active
ENAC LC10.082 Legutiano, ES
CEM DI-007 CEM DI-021 CEM DI-004 CEM DI-018 CEM DI-002 + 3 more
View Profile
ENAC LE178 Madrid, ES
UNE-EN 81-1 UNE-EN 81-2 UNE-EN 81-50 UNE-EN 81-20 UNE-EN 60947-4-1 + 3 more
View Profile
ENAC LE2485 Girona, ES
UNE-EN 25663 UNE-EN 872 UNE-EN ISO 6878 UNE EN 27888 UNE-EN ISO 10523 + 3 more
View Profile

URIKER

Active
ENAC LE775 Zamudio, ES
UNE 77061 SM 4500-NO-3 E UNE-EN ISO 7027-1 ISO 15923-1 UNE-EN ISO 7393-2 + 3 more
View Profile
ENAC LC10.251 Hospitalet de Llobregat, ES
CEM ME009
View Profile
ENAC LC10.179 Pontevedra, ES
5 a 18 mm/s (Valor pico) (frecuencias en 5 a 12 mm/s (RMS) (frecuencias entre 8 H
View Profile

VIRLAB

Active
ENAC LE131 Asteasu, ES
IEC 60068-2-6 UNE-EN 60068-2-6 UNE-EN 60068-2-27 IEC 60068-2-27 UNE-EN 60068-2-57 + 3 more
View Profile
ENAC LE1474 San Sebastián de los Reyes, ES
UNE 73109 IEC 60780 (1998) UNE 73109 (2001) ISO 28218 ISO 27048
View Profile

No matching labs found.

Industries

Aerospace and aircraft maintenance Automotive and engine testing Machinery condition monitoring Mechanical engineering and R&D Vibration diagnostics and predictive maintenance

Related Standards

  • ISO 16063-41 Methods for the calibration of vibration and shock transducers – Calibration of accelerometers
  • ISO 6954 Mechanical vibration – Criteria for the evaluation of vibration on machines with nominal powers above 15 kW and nominal speeds between 120 and 15000 r/min
  • ISO 10816-1 Mechanical vibration – Evaluation of machine vibration by measurements on non-rotating parts

Other Test Methods

0 labs selected
Compare