ISO 5348

Accelerometer Mechanical Mounting Methods

ISO 5348 specifies the mechanical mounting requirements and installation methods for accelerometers used in vibration measurement and monitoring applications. Proper mounting is critical because accelerometer resonance and damping characteristics are strongly influenced by how the device is attached to the test structure. Industries including aerospace, automotive, mechanical engineering, and maintenance rely on this standard to ensure measurement accuracy and repeatability in vibration diagnostics. Accreditation to this standard demonstrates that a laboratory understands the physical factors affecting transducer performance and can provide traceable, reliable vibration data. Correct mounting practices are fundamental to valid vibration measurement across all frequency ranges.

What it measures

  • Transverse sensitivity effects of mounting
  • Frequency response accuracy with different mounting methods
  • Resonance frequency stability
  • Mechanical coupling effects
  • Temperature compensation for mounted accelerometers
🇧🇪 NBN EN ISO 16063-41 🇩🇪 DIN EN ISO 16063-41 🇬🇧 BS EN ISO 16063-41 🇫🇷 NF EN ISO 16063-41 🇮🇹 UNI EN ISO 16063-41 🇪🇸 UNE EN ISO 16063-41 🇳🇱 NEN EN ISO 16063-41 🇧🇪 NBN EN ISO 6954 🇩🇪 DIN EN ISO 6954 🇬🇧 BS EN ISO 6954 🇫🇷 NF EN ISO 6954 🇮🇹 UNI EN ISO 6954
3,021 Accredited labs
22 Countries

Showing 2,801–2,825 of 3,021 labs

Zentrallabor

Active
DAkkS D-ML-13220-01-01 Homburg, DE
(ein- oder mehrgängige Ethanol Absolutdruck tration von Harnsäure tration von Harnstoff + 3 more
View Profile
DAkkS D-ML-13161-02-00 Göttingen, DE
Komplex angeborener Chromosomensatz Glut1-Defizienz-Syndrom Familiärer Brust- und Eierstockkrebs ATP7B; Morbus Wilson + 3 more
View Profile
DAkkS D-ML-13161-01-00 Göttingen, DE
(ein- oder mehrgängige Ethanol Absolutdruck tration von Cholesterol tration von Harnsäure + 3 more
View Profile
DAkkS D-PL-13161-01-00 Göttingen, DE
Ethanol tration von Harnsäure Digitoxin Digoxin Aldosteron + 3 more
View Profile
DAkkS D-ML-13161-05-00 Göttingen, DE
(ein- oder mehrgängige Ethanol Absolutdruck tration von Cholesterol tration von Harnsäure + 3 more
View Profile
DAkkS D-ML-13161-06-00 Göttingen, DE
Komplex angeborener Chromosomensatz Glut1-Defizienz-Syndrom Familiärer Brust- und Eierstockkrebs ATP7B; Morbus Wilson + 3 more
View Profile
DAkkS D-ML-13193-04-00 Rostock, DE
Ethanol tration von Harnsäure tration von Harnstoff pH - Wert pH-Messgeräte 1,68 pH bis 10 pH + 3 more
View Profile
DAkkS D-ML-13193-01-00 Rostock, DE
ASCA IgA Staphylococcus aureus Cryptococcus neoformans MRSA Bakterien, Sprosspilze + 3 more
View Profile
DAkkS D-ML-13193-03-01 Rostock, DE
B-Streptokokken (Screening) Thrombozytäre Antikörper HLA spezifische Antikörper Serologische Verträglichkeitsprüfung (Cross-Match) + 3 more
View Profile
DAkkS D-PL-13258-03-01 Mainz, DE
DIN EN ISO 19458 DIN 1946-4 DIN EN ISO 10523 (C 5) DIN EN 27888 (C 8) DIN EN ISO 10304-1 (D 20) + 3 more
View Profile
DAkkS D-ML-13258-04-00 Mainz, DE
Anti-Thyreoglobulin-Antikörper [Anti-TG] Anti-Thyreoperoxidase Antikörper [Anti-TPO] Anti-TSH-Rezeptor Antikörper + 3 more
View Profile
DAkkS D-ML-13258-01-01 Mainz, DE
*) 1 bar; 2 bar Chorea Huntington (HD)-HTT PTPN11 angeborener Chromosomensatz BRCA-Panel; BRCA1, BRCA2 + 3 more
View Profile
DAkkS D-ML-13258-03-00 Mainz, DE
pH-Messgeräte 1,68 pH bis 10 pH Creatinin Digitoxin Cortisol Hämoglobin + 3 more
View Profile
DAkkS D-ML-13258-05-00 Mainz, DE
Thrombozytäre Antikörper HLA spezifische Antikörper Molekulargenetische Thrombozytenantigene low resolution + 3 more
View Profile
BELAC 639-TEST Louvain-La-Neuve, BE
Méthode interne développée par Panasonic
View Profile
COFRAC 1-6851 Marne-La-Vallee Cedex 2, FR
DIN EN 12431 DIN EN 1767 DIN EN ISO 3251 BS ISO 18771 DIN EN 480-6 + 3 more
View Profile
BELAC 666-TEST Liège, BE
Hämolysine Serum *HIV 1 / 2 Antibody/Antigen | Siem Tissue (Surgical and MH | Fibres with ab SHOCK
View Profile
COFRAC 1-6561 Sainte-Florine, FR
IEC 60068-2-2 IEC 60068-2-53 IEC 60068-2-64 ISO 16750-3 IEC 60068-2-80) + 3 more
View Profile
DAkkS D-PL-12061-01-01 Offenbach am Main, DE
Sound power — in-situ using reference so Sound intensity — scanning method (ISO 9 Hand-arm vibration — practical guidance Railway braking — urban guided transport Railway vehicle body structural requirem + 3 more
View Profile
DAkkS D-PL-11272-01-01 Dortmund, DE
DIN EN IEC 60068-2-13 DIN EN 60068-2-30 DIN EN IEC 60068-2-38 DIN EN 60068-2-64 DIN EN 60068-2-78 + 3 more
View Profile

VDZ Service

Active
DAkkS D-PL-16069-01-01 Düsseldorf, DE
EBM 11444/11445: ID022 DIN EN 27888 DIN EN 12350-3 DIN EN 12350-6 DIN EN 12390-3 + 3 more
View Profile
DAkkS D-PL-18403-01-01 Düsseldorf, DE
EBM 11444/11445: ID022 DIN EN 62196-1: 2015 DIN EN 480-11 DIN EN 12350-1 DIN EN 12350-6 + 3 more
View Profile
UKAS 1634 Whitley Bay, GB
ISO 14644-3 (HSG 264, 2012) Executive guides HSG 264 (2012) (HSG 248) – 2021 and Appendix 3 of HSG 227 (2004)) + 3 more
View Profile
ENAC LC10.251 Hospitalet de Llobregat, ES
CEM ME009
View Profile
DAkkS D-PL-19465-01-00 Darmstadt, DE
Toxizität UGT1A1-Gen rs3064744, rs414832 rs738409 Myopathie, Nemaline (TyP1, 3-10: DIN 53438-3 ASTM D 1322 + 3 more
View Profile

No matching labs found.

Industries

Aerospace and aircraft maintenance Automotive and engine testing Machinery condition monitoring Mechanical engineering and R&D Vibration diagnostics and predictive maintenance

Related Standards

  • ISO 16063-41 Methods for the calibration of vibration and shock transducers – Calibration of accelerometers
  • ISO 6954 Mechanical vibration – Criteria for the evaluation of vibration on machines with nominal powers above 15 kW and nominal speeds between 120 and 15000 r/min
  • ISO 10816-1 Mechanical vibration – Evaluation of machine vibration by measurements on non-rotating parts