ISO 5348

Accelerometer Mechanical Mounting Methods

ISO 5348 specifies the mechanical mounting requirements and installation methods for accelerometers used in vibration measurement and monitoring applications. Proper mounting is critical because accelerometer resonance and damping characteristics are strongly influenced by how the device is attached to the test structure. Industries including aerospace, automotive, mechanical engineering, and maintenance rely on this standard to ensure measurement accuracy and repeatability in vibration diagnostics. Accreditation to this standard demonstrates that a laboratory understands the physical factors affecting transducer performance and can provide traceable, reliable vibration data. Correct mounting practices are fundamental to valid vibration measurement across all frequency ranges.

What it measures

  • Transverse sensitivity effects of mounting
  • Frequency response accuracy with different mounting methods
  • Resonance frequency stability
  • Mechanical coupling effects
  • Temperature compensation for mounted accelerometers
🇩🇪 DIN EN ISO 16063-41 🇬🇧 BS EN ISO 16063-41 🇫🇷 NF EN ISO 16063-41 🇮🇹 UNI EN ISO 16063-41 🇪🇸 UNE EN ISO 16063-41 🇳🇱 NEN EN ISO 16063-41 🇩🇪 DIN EN ISO 6954 🇬🇧 BS EN ISO 6954 🇫🇷 NF EN ISO 6954 🇮🇹 UNI EN ISO 6954 🇪🇸 UNE EN ISO 6954 🇳🇱 NEN EN ISO 6954
1,817 Accredited labs
19 Countries

Showing 326–350 of 1,817 labs

UKAS 1079 Gloucestershire, GB
BS ISO 488:2008, 2446:2008 and on BS 4401:Part 3:1970(1986) BS 696-2:1989 (superseded and BS ISO 6731:2010 ISO BS EN 3727-1:2002 + 3 more
View Profile
UKAS 4301 Llanishen, GB
Electrolytes in blood serum: Enzymes in blood serum: (Chlamydia pneumoniae, Mycoplasma urine: Hormones in blood serum: + 1 more
View Profile

Carl Zeiss

Active
DAkkS D-PL-12125-01-01 Oberkochen, DE
DIN EN 60601-1 IEC 60601-1 DIN EN 60601-1-1 IEC 60601-1-1 IEC 80601-2-77 + 3 more
View Profile
DAkkS D-K-21703-01-00 Oberkochen, DE
Carl Zeiss Industrielle ≤ 3818 mm Oberkochen, D 1) In den CMC sind die erweiterten Messu Carl Zeiss Industrielle ≤ 20 m Auswertesoftware Messvolumen mit + 3 more
View Profile
DAkkS D-PL-12037-01-02 Jena, DE
DIN EN 61010-1 VDE 0411-1 IEC 61010-1 : 2010 DIN EN 60825-1 VDE 0837 + 3 more
View Profile
DAkkS D-K-12037-01-01 Jena, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße * 40 mm Parallelendmaße * ≥ 100 mm Strichmaßstäbe 0 mm + 3 more
View Profile
UKAS 27202 Paisley, GB
(HSG 264, 2012)
View Profile
UKAS 7914 Willsbridge, GB
5 of HSG 227 (2004)) (HSG 264, 2012)
View Profile
UKAS 1643 Chelmsford, GB
(cdt), Deletion an Pos 117 (HSG 248) – 2021 (PCM) based on HSG 248 BS 6068-4.12:1998 (withdrawn)
View Profile

CeGaT

Active
DAkkS D-ML-13206-01-01 Tübingen, DE
angeborener Chromosomensatz (Imbalancen im Genom, (Duplikationen/Del SNRPN-Region 15q11-13 UPD15 (UBE3A) SMN1; Spinale Muskelatrophie + 3 more
View Profile

Cenata

Active
DAkkS D-ML-21205-01-01 Tübingen, DE
Pränatales Screening auf Chromosomenstörungen (Trisomie 21, Trisomie 18, Trisomie 13, X0, XXX, XXY, XYY, XXYY, 22q11 (DiGe
View Profile
COFRAC 1-1970 Chateauneuf Sur Isere, FR
DIN EN 12207 DIN EN 12208 DIN EN 1026 DIN EN 12210 BS EN 14351-1:2006+A2:2016 + 3 more
View Profile

CevLab

Active
ACCREDIA 02206 Carpi, IT
DIN EN 60068-2-64 DIN EN-60068-2-6
View Profile
UKAS 0822 Southam, GB
Calibration of pressure Gas pressure (gauge) Gas Pressure (Differential) common mode pressure of 3.5 Hydraulic pressure (gauge) + 3 more
View Profile
DAkkS D-PL-20168-01-00 Jilin Province, CN
IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-14 IEC 60068-2-30 DIN EN 60068-2-30 + 3 more
View Profile
DAkkS D-ML-13008-09-01 Berlin, DE
Whole genome sequencing (WGS: SNV, CNV/SV)
View Profile
DAkkS D-ML-13008-01-00 Berlin, DE
Thyreoidea stimulierendes (TSH) 17-α-OH-Progesteron (17-OH-P) Immunreaktives Trypsin + 3 more
View Profile
UKAS 0513 Coalville, GB
Liquid-in-glass thermometers ASTM D4052 (Digital density
View Profile

CheckImmune

Active
DAkkS D-ML-21360-01-00 Berlin, DE
Leukozytenzahl B-Zellzahl (Immunstatus Rezeptor-Besatz HLA-DR Leukozytensubpopulationen + 3 more
View Profile

Chelab

Active
ACCREDIA 00051 Resana, IT
ISO 9308-1 ISO 7899-2 ISO 17410 ISO 16266 ISO 19250 + 3 more
View Profile
DAkkS D-PL-14010-01-04 Bensheim, DE
DIN 38402-A 13 DIN ISO 5667-5 (A 14) DIN 38402-A 30 DIN 19643-1 ISO 5667-11 + 3 more
View Profile
UKAS 2613 Salisbury, GB
IEC 60068-2-2 BS 2011:2.1 Ca:1977 IEC 60068-2-30 MIL-STD 331B: 1994: DIN EN 60068-2-78 + 3 more
View Profile
UKAS 10148 Humanby, GB
Sound Calibrators Sound Level Meters One-third octave band filters
View Profile
UKAS 6536 Leicester, GB
(HSG 264, 2012) Appendix 5 of HSG 227 (2004))
View Profile
UKAS 9102 Bellshill, GB
(HSG 248) – 2021 SRV-002 based on HSG 248 (PCM) based on HSG 248
View Profile

No matching labs found.

Industries

Aerospace and aircraft maintenance Automotive and engine testing Machinery condition monitoring Mechanical engineering and R&D Vibration diagnostics and predictive maintenance

Related Standards

  • ISO 16063-41 Methods for the calibration of vibration and shock transducers – Calibration of accelerometers
  • ISO 6954 Mechanical vibration – Criteria for the evaluation of vibration on machines with nominal powers above 15 kW and nominal speeds between 120 and 15000 r/min
  • ISO 10816-1 Mechanical vibration – Evaluation of machine vibration by measurements on non-rotating parts

Other Test Methods

0 labs selected
Compare