ISO 5348

Accelerometer Mechanical Mounting Methods

ISO 5348 specifies the mechanical mounting requirements and installation methods for accelerometers used in vibration measurement and monitoring applications. Proper mounting is critical because accelerometer resonance and damping characteristics are strongly influenced by how the device is attached to the test structure. Industries including aerospace, automotive, mechanical engineering, and maintenance rely on this standard to ensure measurement accuracy and repeatability in vibration diagnostics. Accreditation to this standard demonstrates that a laboratory understands the physical factors affecting transducer performance and can provide traceable, reliable vibration data. Correct mounting practices are fundamental to valid vibration measurement across all frequency ranges.

What it measures

  • Transverse sensitivity effects of mounting
  • Frequency response accuracy with different mounting methods
  • Resonance frequency stability
  • Mechanical coupling effects
  • Temperature compensation for mounted accelerometers
🇧🇪 NBN EN ISO 16063-41 🇩🇪 DIN EN ISO 16063-41 🇬🇧 BS EN ISO 16063-41 🇫🇷 NF EN ISO 16063-41 🇮🇹 UNI EN ISO 16063-41 🇪🇸 UNE EN ISO 16063-41 🇳🇱 NEN EN ISO 16063-41 🇧🇪 NBN EN ISO 6954 🇩🇪 DIN EN ISO 6954 🇬🇧 BS EN ISO 6954 🇫🇷 NF EN ISO 6954 🇮🇹 UNI EN ISO 6954
3,021 Accredited labs
22 Countries

Showing 2,076–2,100 of 3,021 labs

DAkkS D-PL-12104-04-01 Hildesheim, DE
ISO 3795 DIN 75200 ISO 16750-5 ISO 20653 VDE 0468-2-1 + 3 more
View Profile
DAkkS D-ML-13113-01-01 Berlin, DE
Salmonella enterica, Shigellen, Yersinie Cryptococcus neoformans Neisseria gonorrhoeae Enterovirus SARS-CoV-2 + 3 more
View Profile
DAkkS D-K-15195-01-01 Memmingen, DE
(Härteskalen HV0,01 bis HV3) - Gleichspannung - Gleichstromstärke - Gleichstromwiderstand - Wechselspannung + 3 more
View Profile
DAkkS D-K-21801-01-00 Lüdenscheid, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO 1) In den CMC sind die erweiterten Messu elektronische Waagen − Waagen + 1 more
View Profile
DAkkS D-PL-21397-01-01 Leinfelden-Echterdingen, DE
DIN EN ISO 6506-1 DIN EN ISO 6507-1 DIN EN ISO 6508-1 DIN EN 1191 DIN EN 1628 + 3 more
View Profile
DAkkS D-PL-17459-01-00 Münster, DE
P1433, P14-3-3 EBM 11444/11445: ID022 IEC 61850-3: 2014 DIN EN 62196-1: 2015 DIN EN 12350-1 + 3 more
View Profile
UKAS 7959 Reading, GB
Audiology | Adult Hearing Services: Audiology | Otoscopy Audiology | History Taking Audiology | Pure Tone Audiometry Audiology | Impression Taking + 3 more
View Profile
UKAS 8869 Truro, GB
T cells | CD3 Proliferating Cells | Ki67 Volume | Volume/weight Volume | Colorimetric strips Amyloid | Congo Red + 3 more
View Profile
UKAS 8123 Exeter, GB
parameters: Formalin fixed tissue | HIST/GEN-SOP 008 Sweat Sweat Chloride | Coulometry Serum/Plasma Transferrin | Immunoturbidi Sodium | Indirect ISE + 3 more
View Profile
UKAS 8399 Barnstable, GB
Audiology | Adult Hearing Services: Audiology | Otoscopy Audiology | History Taking Audiology | Pure Tone Audiometry Audiology | Impression Taking + 3 more
View Profile
UKAS 9100 Barnstaple, GB
Macrophages | CD68 Plasma cells | CD138 B-Cells | CD79a Lung adenocarcinoma | NAPSIN A Endothelial cells | CD31 + 3 more
View Profile
UKAS 8210 Exeter, GB
parameters: Sweat Sweat Chloride | Coulometry Serum/Plasma Transferrin | Immunoturbidi Sodium | Indirect ISE Serum Chloride | Indirect ISE + 3 more
View Profile
UKAS 9018 Exeter, GB
Escherichia coli | O157 Pus/ Swabs/ Tissues/ fluids, genital Iso Swabs, non-sterile tissues, fluids | – M Sterile tissues and fluids (including | Blood culture | M-BSOP- 8 Blood cultur + 3 more
View Profile
UKAS 8092 Exeter, GB
C. Saliva | 1. Polymerase Chain Reaction I. Cerebrospinal fluid (CSF) | (MG/S J. Blood spots | (MGSOP/MON045) K. Plasma | (MGSOP/MON054) K. Plasma | (MG/SOP/HAE019) + 3 more
View Profile
UKAS 8680 Stanmore, GB
T cells | CD3 Macrophages | CD68 Plasma cells | CD138 Squamous epithelium | P63 Thyroid Transcription Factor-1 | TTF1 + 3 more
View Profile
UKAS 9403 Bath, GB
T cells | CD3 Macrophages | CD68 Plasma cells | CD138 Proliferating Cells | Ki67 Germ cell tumours | PLAP + 3 more
View Profile
UKAS 8407 Lyndon, GB
Urine | Cocaine Urine | Methadone Urine | Amphetamine Urine | Spectrophotometer Urine | MDMA + 3 more
View Profile

Ruhr Lab

Active
DAkkS D-PL-21007-01-00 Gelsenkirchen, DE
EN ISO 1716 DIN EN 60950-1 DIN EN 196-2 DIN 18123 DIN EN 196-7 + 3 more
View Profile
DAkkS D-PL-19612-01-00 Gelsenkirchen, DE
ID116 (LBLS) (OMIM 611105) (c.228- ASTM D 4052 DIN EN ISO 12185 DIN EN ISO 3405 + 3 more
View Profile
DAkkS D-ML-13425-01-00 Bochum, DE
HD; Chorea Huntington Hereditäre spastische Paraplegie Spinocerebelläre Ataxien Whole Exome Sequencing SOD1-Gen, Amyotrophe Lateralsklerose + 3 more
View Profile
RvA L638 Kicukiro District, Kigali City, RW
ISO 4832 ISO 16649-2 ISO 6611 ISO 6579-1 ISO 6222 + 3 more
View Profile
DAkkS D-K-20577-01-00 Kigali, DE
> 0 bar > 70 bar > 100 mg > 200 mg > 500 mg + 3 more
View Profile
ACCREDIA 00531 Nocera Superiore, IT
IEC 60512-17-1 ISO 18787 ISO 4832 ISO 15214 ISO 21527-1 + 3 more
View Profile
ENAC LC10.069 Sant Celoni, ES
15 · 10-6 mol/mol  C  3500 · 10-6 mol/ 0,03 · 10-2 mol/mol  C < 0,3 · 10-2 mol 0,3 · 10-2 mol/mol  C  1,1 · 10-2 mol/ 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m 1,1 · 10-2 mol/mol ≤ C < 26 · 10-2 mol/m + 3 more
View Profile
DAkkS D-K-21982-01-00 Mönchengladbach, DE
Railway overhead lines — pantograph head Volumendurchfluss dV/dt von dm/dt von − Durchfluss von Flüssigkeiten + 3 more
View Profile

No matching labs found.

Industries

Aerospace and aircraft maintenance Automotive and engine testing Machinery condition monitoring Mechanical engineering and R&D Vibration diagnostics and predictive maintenance

Related Standards

  • ISO 16063-41 Methods for the calibration of vibration and shock transducers – Calibration of accelerometers
  • ISO 6954 Mechanical vibration – Criteria for the evaluation of vibration on machines with nominal powers above 15 kW and nominal speeds between 120 and 15000 r/min
  • ISO 10816-1 Mechanical vibration – Evaluation of machine vibration by measurements on non-rotating parts

Other Test Methods