ISO 5348

Accelerometer Mechanical Mounting Methods

ISO 5348 specifies the mechanical mounting requirements and installation methods for accelerometers used in vibration measurement and monitoring applications. Proper mounting is critical because accelerometer resonance and damping characteristics are strongly influenced by how the device is attached to the test structure. Industries including aerospace, automotive, mechanical engineering, and maintenance rely on this standard to ensure measurement accuracy and repeatability in vibration diagnostics. Accreditation to this standard demonstrates that a laboratory understands the physical factors affecting transducer performance and can provide traceable, reliable vibration data. Correct mounting practices are fundamental to valid vibration measurement across all frequency ranges.

What it measures

  • Transverse sensitivity effects of mounting
  • Frequency response accuracy with different mounting methods
  • Resonance frequency stability
  • Mechanical coupling effects
  • Temperature compensation for mounted accelerometers
🇧🇪 NBN EN ISO 16063-41 🇩🇪 DIN EN ISO 16063-41 🇬🇧 BS EN ISO 16063-41 🇫🇷 NF EN ISO 16063-41 🇮🇹 UNI EN ISO 16063-41 🇪🇸 UNE EN ISO 16063-41 🇳🇱 NEN EN ISO 16063-41 🇧🇪 NBN EN ISO 6954 🇩🇪 DIN EN ISO 6954 🇬🇧 BS EN ISO 6954 🇫🇷 NF EN ISO 6954 🇮🇹 UNI EN ISO 6954
3,021 Accredited labs
22 Countries

Showing 2,226–2,250 of 3,021 labs

Sakosta

Active
DAkkS D-PL-21836-01-01 Düsseldorf, DE
DIN EN 932-1 DIN EN ISO 22476-2 DIN 18134 DIN ISO 16000-18 DIN ISO 16000-20 + 3 more
View Profile

Sakosta

Active
DAkkS D-PL-22056-01-01 Dreieich, DE
DIN EN 932-1 DIN EN ISO 22476-2 DIN 18134 DIN ISO 16000-18 DIN ISO 16000-20 + 3 more
View Profile
DAkkS D-K-15008-01-01 Gladbeck, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Sound power — engineering method using a Railway brake — magnetic track brakes (U Railway brakes — conditions for homologa + 3 more
View Profile
UKAS 9687 Salisbury, GB
HUMAN BODY FLUIDS: Biochemistry examinat Quantitative determination of: | Beckman Serum / Plasma / Urine Sodium | SOP Lab Serum / Plasma / Urine Potassium | SOP L Serum / Plasma / Urine Urea | SOP Lab Me + 3 more
View Profile
UKAS 8363 Salisbury, GB
Materials/Products | Type of test/Proper
View Profile
UKAS 8348 Salisbury, GB
Serum, Plasma | Detection of: Electroche Serum, Plasma | Roche COBAS 8000 e801/c7 Serum, Plasma | Analyser Serum, Plasma | Hepatitis B surface anti Serum, Plasma | Hepatitis C MIC-SOP-153 + 3 more
View Profile
DAkkS D-PL-18292-01-01 Salzgitter, DE
DIN EN ISO 7438 DIN EN ISO 5173 DIN EN ISO 6506-1 DIN EN ISO 6507-1 ISO 11948-1 + 3 more
View Profile
DAkkS D-PL-11299-01-00 Mülheim an der Ruhr, DE
Tensile testing of metallic materials (I Charpy impact test (ISO 148-1) DIN EN ISO 7438 DIN EN ISO 4136 DIN EN ISO 5173 + 3 more
View Profile
UKAS 7979 Birmingham, GB
Audiology | Adult Hearing Services: Audiology | Otoscopy Audiology | History Taking Audiology | Pure Tone Audiometry Audiology | Impression Taking + 3 more
View Profile
DAkkS D-K-19398-01-01 Göttingen, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) > 100 G Innen- und Tiefenmaße + 3 more
View Profile
DAkkS D-PL-14437-01-02 Essen, DE
ID116 DIN 51757 ASTM D 4052 DIN EN ISO 12185 DIN EN ISO 3405 + 3 more
View Profile
DAkkS D-PL-17225-01-01 Darmstadt, DE
ISO 2954 ISO 21940-21
View Profile
DAkkS D-K-21919-01-01 Berlin, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) − Waagen Optoelektronische + 1 more
View Profile
DAkkS D-PL-20648-01-01 Marktheidenfeld, DE
DIN EN 50155 IEC 61000-4-2: 2008 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile
DAkkS D-PL-21279-01-00 Thale, DE
DIN EN ISO 6507-1 DIN EN ISO 643 DIN EN ISO 6892-2 DIN EN ISO 3369 ISO 6507-1 + 3 more
View Profile
DAkkS D-K-20651-02-01 Schönau, DE
- Gleichstromwiderstand - Kapazität - Induktivität Quellen Antennenfaktor + 3 more
View Profile
DAkkS D-K-15216-01-00 Langenfeld, DE
Sound intensity — scanning method (ISO 9 Acoustics — tonality assessment (DIN 456 Acoustics — in-situ measurement of sound Railway air brakes for freight and passe messeinrichtungen von + 3 more
View Profile
UKAS 2577 Redruth, GB
(HSG 248) – 2021 (PCM) based on HSG 248 D3TA2 based on HSG 248 D3TA8 based on HSG 248
View Profile

Scope iT

Active
UKAS 9086 Manchester, GB
(HSG 264, 2012) Appendix 5 of HSG 227 (2004))
View Profile
UKAS 10483 Ossett, GB
(HSG 248) – 2021 staining based on HSG 248 SAC-SOP-15 based on HSG 248 SAC-SOP-07 based on HSG 248
View Profile
UKAS 0809 Peterlee, GB
DC Resistance DC RESISTANCE (continued) DC VOLTAGE Generation (continued) Measurement (continued) + 3 more
View Profile
RvA L540 Bergschenhoek, NL
IEC 60068-2-6 IEC 60068-2-27 IEC 60068-2-64 Clause 5, IEC 60068-2-31
View Profile
ACCREDIA 01827 Roma, IT
ETSI EN 319 401 ETSI EN 319 411-1 ETSI EN 319 411-2 ETSI EN 319 412
View Profile

Sedus Stoll

Active
DAkkS D-PL-17145-01-00 Dogern, DE
ISO 21527-1 DIN EN 12102-2 DIN EN 12520 DIN EN 1335-1 DIN EN 15372 + 3 more
View Profile
UKAS 2210 Wilton International, GB
(HSG 248) – 2021 (PCM) based on HSG 248 DI/AN/ME/025 based on HSG 248 DI/AN/ME/001 based on HSG 248 DI/AN/ME/026 based on HSG 248
View Profile

No matching labs found.

Industries

Aerospace and aircraft maintenance Automotive and engine testing Machinery condition monitoring Mechanical engineering and R&D Vibration diagnostics and predictive maintenance

Related Standards

  • ISO 16063-41 Methods for the calibration of vibration and shock transducers – Calibration of accelerometers
  • ISO 6954 Mechanical vibration – Criteria for the evaluation of vibration on machines with nominal powers above 15 kW and nominal speeds between 120 and 15000 r/min
  • ISO 10816-1 Mechanical vibration – Evaluation of machine vibration by measurements on non-rotating parts

Other Test Methods

0 labs selected
Compare